CHAPTER 416 - STANDARDS ACT: SUBSIDIARY LEGISLATION

 

INDEX TO SUBSIDIARY LEGISLATION

Zambia Bureau of Standards (Standards and Certification Marks) Regulations

Zambia Bureau of Standards (Calibration Service) Regulations

Standards (Compulsory Standards) (Declaration) Order

Standards (Imports) (Quality Monitoring) Regulations, 2003

Standards (Compulsory Standards)(Declaration) Order, 2003

Standards (Compulsory Standards) (Declaration) Order, 2009

Standard (Compulsory Standards) (Declaration) Order, 2011

Standards (Compulsory Standards) (Fees) Regulations, 2012

Standard (Compulsory Standards) (Chalk) (Declaration) Order, 2013

Standards (Compulsory Standards) (Declaration) Order, 2013

Standards (Compulsory Standards) (Declaration) Order, 2017

Standards Act (Commencement) Order, 2017

 

STANDARDS (STANDARDS AND CERTIFICATION MARKS) REGULATIONS

[Section 37]

Arrangement of Regulations

   Regulation

   1. Title

   2. Interpretation

   3. Authority

   4. Application for authority

   5. Inspection

   6. Condition of authority

   7. Periodic inspection

   8. Declaration of dispute

   9. Register of authorised persons and products

   10. Inspection of register

[Regulations by the Minister]

Act 72 of 1994.

 

1. Title

These Regulations may be cited as the Zambia Bureau of Standards (Standards and Certification Marks) RegulationsThese Regulations made under Act. No. 22 of 1982 (repealed) are continued in force by the provisions of section 15 of the Interpretation and General Provisions Act1.

 

2. Interpretation

In these Regulations, unless the context otherwise requires—

“authority” means the written authority obtained from the Bureau to apply a certification mark;

“authorised person” means a person who has been granted authority to use a certification mark;

“inspection” includes the process of examining and conducting of relevant tests by the Bureau to determine the conformity of any commodity with a declared standard.

 

3. Authority

The written Authority referred to in section 14(1) of the Act shall be in Form ZABS/1 set out in the Schedule.

 

4. Application for authority

An application for use or renewal of authority shall be in Form ZABS/2 set out in the Schedule.

 

5. Inspection

The Bureau shall not consider an application for an authority unless an inspector has been to the applicant’s premises and has together with the applicant completed Form ZABS/3 set out in the Schedule.

 

6. Condition of authority

   (1) The authority issued by the Bureau shall be subject to the following general conditions—

   (a)   the authorised person shall comply with the general and specific conditions and scheme of supervision and control which the Bureau may issue from time to time;

   (b)   the authority shall not be transferable;

   (c)   costs incurred by inspectors, to determine whether commodities to which a certification mark has been applied fulfil the applicable requirements laid down by the Bureau, shall be borne by the authorised person to the extent specified in the scheme of supervision and control for the commodities listed in the authority;

   (d)   the right to use a certification mark applies only to the commodities listed in the authority;

   (e)   costs incurred in applying a certification mark shall be borne by the authorised person;

   (f)   the Bureau reserves the right to revise the procedures for marking standardised commodities;

   (g)   if the declared standard on which the authority is based is revised, the authority shall be valid only if the authorised person agrees to comply with the requirements set out in the revised declared standard;

   (h)   the authority shall be valid for one year from the date of issue unless earlier revoked.

   (2) The Bureau shall impose any other conditions on the Authority as it thinks fit.

 

7. Periodic inspection

The Bureau shall periodically send an inspector to the authorised person’s premises and the inspector shall complete Form ZABS/4 set out in the Schedule.

 

8. Declaration of dispute

Any person aggrieved by the refusal of the Bureau to grant authority may within twenty-one days declare a dispute by completing Form ZABS/5 set out in the Schedule.

 

9. Register of authorised persons and products

The Bureau shall keep a register of all authorised persons and the products in respect of which an authority has been issued

 

10. Inspection of register

Any person may, on payment of the appropriate fee, inspect the register.

 

FORM ZABS/1

THE REPUBLIC OF ZAMBIA

STANDARDS ACT

STANDARDS (STANDARDS AND CERTIFICATION MARKS) REGULATIONS

AUTHORITY TO USE A CERTIFICATION MARK

[Regulation 3]

No............................

This authority is granted to ………………………of …………………………………………………...to use the certification mark specified in Statutory Instrument No…………………of 19....................., and in respect of ………………………………………………….………………….commodity/process which commodity/process conforms to ……………………………………................…………………………declared standard or approved specification mark.

This authority is issued subject to the general conditions contained in the Zambia Bureau of Standards (Standards and Certification Marks) Regulations, 1987, and the following additional condition(s) ……………………………….....................................................................................................................................

Date............................................................

............................................................
Director

 

FORM ZABS/2

THE REPUBLIC OF ZAMBIA

STANDARDS ACT

STANDARDS (STANDARDS AND CERTIFICATION MARKS) REGULATIONS

APPLICATION FOR GRANT/RENEWAL OF AUTHORITY

[Regulation 4]

The Director, Zambia Bureau of Standards

1. Delete as applicable*I/We, carrying on business at ……………………………………………………………………………………………………………………………………….(full business address) under the name of …………………………………………………………................ (full name of individual or firm) hereby apply for GRANT OF AUTHORITY/RENEWAL OF AUTHORITY No ……………………. to use the certification mark in respect of the article/class of articles/process which conforms to the declared standard(s) listed below—

   (a)   Article……………………………………………………………………………………………………………………….

Type………………………………………………………………………………………………………………...............

Size…………………………………………………………………………………………………………………………

Grade……………………………………………………………………………………………………………………….

   (b)   Class of articles.……………………………………………………………………………………………………………..

Type………………………………………………………………………………………………………………….........

Size………………………………………………………………………………………………………………………...

Grade………………………………………………………………………………………………………………………

   (c)   Process ………………………………………………………………………………………………………

Only one of the three items under (a), (b) and (c) may be covered by one application.
Delete the other two.

   (d)   Related declared standard(s)

No. .......................................  Title............................................

No. .......................................  Title............................................

2. The above article(s) is/are manufactured by …………………………………………………………………………………………….……………………………………………………………………………………………………………carried out ……………………(factory) on the premises situated at . …………………………………………..........................................................(address)

3. Production figures for the said article(s)/process and the value thereof to the best of my/our knowledge and estimates are as follows:

Year

Production

Unit

Value K

 

Last year from………………… ....to…………………….....

Current year from………………... to………………………

(estimates)

4. In order to ensure conformity of the said article(s)/process to the related declared standard(s)—

Delete as applicable*I/We have in use/propose to use the scheme of inspection and testing described in the statement attached hereto. Routine records of all the inspections and tests are being/will be kept in the form detailed in the statement. I/We further undertake to modify, amend or alter my/our scheme of inspection and testing to bring it in line with that which may be specified by the Bureau from time to time.

Delete as applicable*I/We have at present no scheme of inspection and testing in operation.

I/We, however, undertake to put in operation any such scheme as recommended by the Bureau.

5. Should any initial enquiry be made by the Bureau I/We agree to extend to the Bureau all reasonable facilities at my/our command and I/We also agree to pay all expenses of the said enquiry, including charges for testing, as and when required by the Bureau.

6. Should the authority be granted and as long as it will remain operative, I/We hereby undertake to abide by all the terms and conditions of the Bureau and the Regulations prescribed under the Act. In the event of the authority being suspended or cancelled, I/We also undertake to cease with immediate effect to use the authority and to withdraw all relevant advertising matters and to take such other steps as may be necessary to fulfil the provisions of the Act.

Dated this.................................day of………………………………………………………….

Signature…………………………………………………………………………………………

Name……………………………………………………………………………………………..

Designation………………………………………………………………………………………

For and on behalf of……………………………………………………………………………..

………………………………………………………………………………………(name of firm)

 

FORM ZABS/3

THE REPUBLIC OF ZAMBIA

STANDARDS ACT

STANDARDS (STANDARDS AND CERTIFICATION MARKS) REGULATIONS.

PRELIMINARY INSPECTION REPORT

[Regulation 5]

No.................................................................

1. GENERAL INFORMATION

1.1 Applicant’s name…………………………………………………………………………………………..

1.2 Address……………………………………………………………………………………………………..

1.3 Situation of factory…………………………………………………. Telephone No................................

1.4 Management Staff ............................................................Person(s) Contacted

(i)

(ii)

2. PRODUCTION INFORMATION

2.1 Product name

2.2 Applicable declared standard

2.3 Type……………………………………………Size ............................... Grade .........................

3. RAW MATERIALS

3.1 Raw materials used—

   (a)…………………………………………………………………………………………………...

   (b)…………………………………………………………………………………………………...

   (c)……………………………………………………………………………………………………

   (d)……………………………………………………………………………………………………

3.2 Sources of supply—

   (a)…………………………………………………………………………………………………….

   (b……………………………………………………………………………………………………..

   (c)…………………………………………………………………………………………………….

   (d)…………………………………………………………………………………………………….

3.3 Mode of receipt (batches, lots, nature of package)……………………………………...
………………………………………………………………………………………………………………………

3.4 Test certificate of suppliers…………………………………………………………….....

3.5 Arrangement for testing as received……………………………………………………..

3.6 Details of sampling………………………………………………………………………..

3.7 Methods of disposal of sub-standard raw materials………………………………………
……………………………………………………………………………………………………………………….

3.8 Record of tests with pro forma of records……………………………………………….

4. MANUFACTURE

4.1 Type/Grade being manufactured at the time of inspection—

   (a)   …………………………………………………………………………………………………..

   (b)   …………………………………………………………………………………………………..

   (c)   …………………………………………………………………………………………………..

4.2 Description of process from raw materials to finished product stage…………………………………
………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………

4.3 Intermediate points where control has to be exercised………………………………………………………
………………………………….………………………………………………………………………………
………………………………………………………………………………………………………………………

4.4 Details of records maintained and controls used……………………………………………………………
………………………………………………………………………………………………………………………...

4.5 Methods of disposal of sub-standard products………………………………………………………………
………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………
………………………………………………………………………………
………………………..

4.6 Units of production…………………………………………………………………………………………………………………….

4.7 Production per day or per shift…………………………………………………………………………………………………………

5. PACKAGING AND MARKING

5.1 Nature of package in……………………………………………………………………………………………………………………

5.2 Quantity per packaging…………………………………………………………………………………………………………………

5.3 Marking on article………………………………………………………………………………………………………………………

5.4 Method of marking……………………………………………………………………………………………………………………..

(printing, stencilling, embossing, etc.)

5.5 Form of label(s) if any………………………………………………………………………………………………………………….

5.6 Batch or code numbering for identification…………………………………………………………………………………………….

6. LABORATORY AND INSPECTION

6.1 Details of staff………………………………………………………………………………………
………………………………………………………………………………………………………………….

6.2 Equipment and other facilities for complete specification testing…………………………………………...........
………………………………………………………………………………………………………………………………

6.3 Accuracy of instruments and arrangements for calibration………………………………………………..
………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………
………………………………………………………………………………
………………………….

6.4 Any laboratory where the firm could test its products…………………………………………………………
………………………………………………………………………………………………………………………....
……………………………………………………………………………………………………………………........

6.5 Records maintained in laboratory for routine tests…………………………………………………………......
………………………………………………………………………………..............................................................

6.6 Stages of processing where laboratory reports are made available………………………………………..
………………………………………………………………………………..........................................................

6.7 Sampling and testing of end products…………………………………………………………………………
………………………………………………………………………………...........................................................

7. SAMPLE

7.1 Type, size and grade of the sample…………………………………………………………………...............
…………………………………………………………………………………………………………………...........

7.2 Details of counter sample………………………………………………………………………………….........
………………………………………………………………………………………………………………………....
………………………………………………………………………………
……………………………...................

7.3 How sealed………………………………………………………………………………………………….........
………………………………………………………………………………………………………….......................

7.4 Laboratory to which despatched…………………………………………………………………………...........
……………………………………………………………………………………………………………....................

7.5 Test results on a sample if tested in factory…………………………………………………………….............
………………………………………………………………………………………………………………..................

7.6 Any further information regarding sample drawn…………………………………………………………..........
………………………………………………………………………………...............................................................

7.7 Information regarding sample of other type/grade applied for……………………………………………........
……………………………………………………………………………………………………………....................

8. OTHER INFORMATION

8.1 Main buyers and selling price………………………………………………………………………....................
………………………………………………………………………………………………………………….............

8.2 Storage facilities……………………………………………………………………………………………..........
………………………………………………………………………………………………………….........................

8.3 Hygienic conditions (in case of food products)………………………………………………………….............
………………………………………………………………………………...............................................................

8.4 Discussion with the firm on scheme of testing and inspection…………………………………………….........
……………………………………………………………………………………………………………………….........

9. CONCLUSION, RECOMMENDATIONS

………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………

Signature…………………………………………………………Inspected by……………………………………

Date…………………………………………………….

 

FORM ZABS/4

THE REPUBLIC OF ZAMBIA

ZAMBIA BUREAU OF STANDARDS ACT

STANDARDS (STANDARDS AND CERTIFICATION MARKS) REGULATIONS

PERIODIC INSPECTION REPORT

[Regulation 7]

AUTHORITY NO……………………………………………………………………………..

1. AUTHORISED PERSON…………………………………………………………………

1.2 Address…………………………………………………………………………………..

1.3 Person(s) contacted…………………………………………………………………….

2. PRODUCT NAME………………………………………………………………………...

2.1 Date of inspection……………………………………………………………………….

3. PREVIOUS INSPECTION

3.1 Date…………………………………… Conducted by…………………………………

3.3 Conclusion and recommendation………………………………………………………

3.4 Action in advice rendered in previous inspection or otherwise asked for……………

4. Changes since previous inspection……………………………………………………....
………………………………………………………………………………………………….

4.1 TECHNICAL………………………………………………………………………………..
…………………………………………………………………………………………………..
…………………………………………………………………………………………………..

Authority No…………………….....................

4.2 Administrative………………………………………………………………………………...........................
………………………………………………………………………………………………………………………

5. DESCRIPTION OF ARTICLE(S) BEING MANUFACTURED AT THE TIME OF INSPECTION

……………………………………………………………………………………………………………………...
………………………………………………………………………………………………………………………
………………………………………………………………………………………………………………………
…………………………………………………………………………................................................................

6. RAW MATERIALS

6.1 Name of major ones*………………………………………………Supplier*……………………………………

6.2 Does the firm test the major raw materials or does it depend on test certificates from suppliers?
………………………………………………………………………………............................................................

6.3 Maximum and minimum values of principal requirements……………………………………………………
………………………………………………………………………………………………………...........................

6.4 Disposal of sub-standard raw materials…………………………………………………………………………
……………………...…………………………………………………………………………………………………...

7. PRODUCTION AND SUPPLY (from ………………………………………to.............................................)

7.1 Quantity produced…………………………………………………….

7.2 Quantity marked……………………………………………………….

7.3 Quantity unmarked……………………………………………………

7.4 Reasons for not marking ……………………………………………….……………………………………….................................................

7.5 Parties supplies to ………………………………………………………………………………………………
………………………………………………………………………………………………………………………....

8. STORING, PACKING AND MARKING

8.1 Material held in stock……………………………………………………..

8.2 Condition of storing……………………………………………………….

8.3 Packing and marking on packages…………………………………… ..

8.4 At what stage is marking done (after or before test results are known)……………………………………………………………

*Attach list………………………………

Authority No……………………............

8.5 Any change in the marking procedure from approved one ……………………………………………………………………........................

9. PRODUCTION CONTROL

9.1 How is the control system operated? ..........................................................................................................................

9.2 Variation in test results for principal requirements (append test results, if necessary or if required by the instruction sheet for the standard) ………………………………………………………………………………………………........................
………………………………………………………………………………………………………………..

9.3 Are the test records maintained satisfactorily? ................................................................................................................................................................

9.4 What is the percentage of rejections, their reasons and manner of disposal? .................................................................................................................................................................

9.5 Whether the failure is due to inherent causes or chance cause………………………………….....
………………………………………………………………………………………………………………....

10. TESTING IN FACTORY

10.1 Requirements tested with results (use laboratory pro forma) ………………………………………………………………………..............................................................

10.2 Comparison of results obtained with firm’s records ..………………………………………………………………………………….............................................

10.3 Comparison of results with the requirements of the specifications …………………………………………………………………......................................................................

10.4 Are the instruments used caliberated periodically? ...................................................................................................................................................................

10.5 Are the instruments used reasonably accurate? ....................................................................................................................................................................

10.6 Any addition in the existing testing equipment? ....................................................................................................................................................................

11. SAMPLES FOR INDEPENDENT TESTS

11.1 Number of samples drawn ……………………………………………………………………………………………………………..........

11.2 From where sampled? ....................................................................................................................................................................

Authority No…………………….......

11.3 Code number/batch number/date of manufacture, etc., of the lot sampled and other markings ………………………………..........................................................................................................................

11.4 Test record of the batch from which sample is drawn ………………………………………….............
……………………………………………………………………………………………………………………..

11.5 Samples brought in or left with the firm for despatch to testing laboratory ……………………………………………………….........................................................................................

11.6 Laboratory to which sample is sent/proposed to be sent …………………………………………………………………………...............................................................

11.7 Details of counter sample left with the firm ………………………………………………………………………………………….........................................

11.8 Any further information ………………………………………………………………………………………………………………...........

12. FOOD ARTICLES (indicate the hygienic conditions maintained in the factory)

……………………………………………………………………………………………………………………
…………………………………………………………………………………………………………...............

13. CONCLUSION AND RECOMMENDATIONS

13.1 Has the scheme operated satisfactorily for this period since last inspected? ........................................................................................................................................................................

13.2 Assessment of the operation of the scheme based on the present vis-a-vis past performance ………………………………...........................................................................................................................

13.3 Any discussion with the firm on any point of interest, e.g. any difficult in operation, irregularities observed in the operation .....................................................…………………………………………………………………

13.4 Any action to be taken including suspension …………………………………………………………………………………………...........................................

13.5 Any other observations/comments …………………………………………………………………………………………………….............................

File Ref.

Signature………………………

Date…………………………..

Authority No…………………

REMARKS OF THE REVIEWING OFFICER

………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………

 

FORM ZABS/5

THE REPUBLIC OF ZAMBIA

STANDARDS ACT

ZAMBIA BUREAU OF STANDARDS (STANDARDS AND CERTIFICATION MARKS) REGULATIONS, 1987

DECLARATION OF A DISPUTE

[Regulation 8]

To: The Director, Zambia Bureau of Standards

*I/We, ..................................................................................................................................carrying on business at ………………………………………………………………………………………………………….... (full business address) under the name of …………………………………………………………………………(full name of individual or firm) hereby, pursuant to the provisions of section 25(2) of the Zambia Bureau of Standards Act, declare a grievance stated hereunder: ..................................................................................................................... ………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………………

(Here state the facts concisely in numbered paragraphs)

*I/We, the said ...............................................………………………………………………………………..do hereby refer the said matters in grievance to the Arbitrators.

Dated this……………………………………………………..day of…………………………………….......................

Signature………………………………………………………

Name…………………………………………………………..

*Delete as applicable

Designation………………………………………………………..

For and on behalf of……………………………………………………………….(Name of firm)

 

ZAMBIA BUREAU OF STANDARDS (CALIBRATION SERVICE) REGULATIONS

[Section 31]

Arrangement of Regulations

   Regulation

   1. Title

   2. Interpretation

   3. Categories of instruments and equipment to be calibrated

   4. Documentation received with instrument

   5. Re-calibration of measuring instrument

   6. Information required

   7. Calibration certificate

   8. Penalty

      FIRST SCHEDULE

[Regulations by the Minister]

SI 72 of 1994.

 

1. Title

These Regulations may be cited as the Zambia Bureau of Standards (Calibration Service) RegulationsThese Regulations made under Act. No. 22 of 1982 (repealed) are continued in force by the provisions of section 15 of the Interpretation and General Provisions Act1.

 

2. Interpretation

In these Regulations, unless the context otherwise requires—

“bureau” means the Bureau stablished by section 3 of the Zambia Bureau of Standards Act;

“calibration” means all stages of any process aimed at or determining the degrees of the errors of a measuring instrument, as well as, where necessary, for the purpose of determining other metrological properties;

“measuring instrument” includes any device such as a graduated rule, set of weights, equal-arm balance, U-tube manometer, clock, ammeter, and others intended for the purpose of measurement and which may reproduce one or more known values of a given quantity, or provide an indication of the value of the measured quantity of equivalent information or which combines these functions;

“metrology” means the field of knowledge concerned with measurements and includes theoretical and practical aspects of measurements, at whatever level of accuracy, and in whatever fields of science or technology they occur;

“primary standard” means a standard which has the highest metrological qualities;

“standard” means a material measure, measuring instrumentor system such as the one kilogram mass, standard gauge block, the 100 ohm standard resistor, the standard ammeter, the caesium atomic frequency standard and others, intended to define, realise, conserve or reproduce a unit or one or more known values of a quantity in order to transmit them to other measuring instruments by comparison;

“traceability” means the ability to trace the calibration of a measuring instrument to a more accurate and recognised standard.

 

3. Categories of instruments and equipment to be calibrated

   (1) The Director shall, by notice, in the Gazette prescribe the categories of instruments and equipment which shall be calibrated by the Bureau and shall on that notice state—

   (a)   the date by which all instruments and equipment within that category shall be calibrated;

   (b)   the Standard to be used for calibration;

   (c)   the interval between each calibration; and

   (d)   the fee to be paid for calibration.

   (2) Where a notice has been published under sub-regulation (1), the person responsible for the operation of the equipment or instrument affected shall deliver to the Bureau all relevant information in the approved form.

   (3) A person who operates a prescribed equipment or an instrument which should have been calibrated but does so without a calibration certificate in respect thereof shall be guilty of an offence.

 

4. Documentation received with instrument

Every person who supplies a measuring instrument shall provide the user of the instrument with all the necessary documentation relating to the operation, servicing or repairing of the measuring instrument:

Provided that the documentation shall be in accordance with the existing standard for such documentation.

 

5. Re-calibration of measuring instrument

Every calibrated measuring instrument which is repaired or serviced shall, before being taken into use, be re-calibratred after such repair or service.

 

6. Information required

The Director may, by notice in writing, require a person to furnish information on any measuring or test instrument or piece of equipment within the period specified in the notice and a person who fails to comply with that notice shall be guilty of an offence.

 

7. Calibration certificate

   (1) The Bureau shall issue a calibration certificate in respect of equipment or an instrument which has been calibrated and the certificate shall be in the approved form stating-

   (a)   the date and place of issue;

   (b)   details of the measurement results; and

   (c)   the calibration date.

   (2) Where a calibration certificate has been issued, a calibration mark in the form shown in the First Schedule to these Regulations shall be affixed to the calibrated instrument.

   (3) The Bureau shall seal access to adjustable devices on the calibrated instrument or equipment that are fixed at the time of calibration and a seal shall be so designed that any tampering with it shall destroy it.

 

8. Penalty

A person who commits an offence under these regulations shall be liable to a fine not exceeding one hundred penalty units or to imprisonment for a term not exceeding six months, or to both.

[Am by Act 13 of 1994.]

 

FIRST SCHEDULE

[Regulation 7]

CALIBRATION MARK

Zambia Calibration Service

Instrument: Serial No.

Date Calibrated:

By:

Certificate No.

Recalibration due:

 

STANDARDS (COMPULSORY STANDARDS) (DECLARATION) ORDER

   Paragraph

   1. Title

   2. Declaration of compulsory standards

   3. Application of standards

      FIRST SCHEDULE

      SECOND SCHEDULE

SI 33 of 2009,

<BC:0,0,0,DC>SI 2 of 2012.

 

1. Title

This Order may be cited as the Standards (Compulsory Standards) (Declaration) Order, 2009.

 

2. Declaration of compulsory standards

The standards set out in the First Schedule to this Order are hereby declared as compulsory standards.

 

3. Application of standards

The standards set out in First Schedule shall apply to the respective commodities listed in the Second Schedule.

 

FIRST SCHEDULE

(Paragraph 2)

COMPULSORY STANDARDS ZAMBIA BUREAU OF STANDARDS

Zambia Standard ZS 369

Automotive Gasoil (diesel fuel)—Specifications

1   Scope

This Zambian Standard specifies requirements for automotive gasoil (diesel fuel). It also specifies the requirements for low sulphur gasoil used in underground mines in the Republic of Zambia.

2   Normative Reference

In this Standard, reference has been made to the following standards:

ASTM D86 Test method for Distillation to the following standards:

ASTM D93 Test Method for Flashpoint by Pensky-Martens Closed Cup.

ASTM D95 Test Method for Water in Petroleum Products and Bituminous material by Distillation.

ASTM D130 Test method for Detection of Copper Corrosion from Petroleum Products by the Copper Strip tarnish Test.

ASTM D445 Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity).

ASTM D 482 Test Method for Ash from Petroleum Products.

ASTM D 524 Test Method for Ramsbottom Carbon Residue of Petroleum Products.

ASTM D 613 Test Method for Cetane Number of Diesel Fuel Oil.

ASTM D 664 Test Method for Acid Number of Petroleum Products by Potentiometric Titration.

ASTM D 976 Methods for Calculated Cetane Index of Distillate Fuels.

ASTM D 1298 Practice for Density, Relative Density (Specific Gravity), or APIGravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method.

ASTM D 1500 Test Method for ASTM Colour of Petroleum Products (ASTM Colour Scale).

ASTM D 1796 Test Method for Water and Sediment in Fuel Oils by the Centrifuge Method (Laboratory Procedure).

ASTM D 2500 Test Method for Cloud Point of Petroleum Products.

ASTM D 2622 Test method for Sulphur in Petroleum Products by X-ray Spectrometry.

ASTM D 5453 Test Method for the Determination of Total Sulphur in

Light Hydrocarbons, Motor Fuels and Oils by Ultraviolet Fluorescence.

ZS 396 Sampling Petroleum Products: Part 1 : Manual Sampling of Liquid Hydrocarbons

Note

ASTM - Methods published by the American Society for Testing and Materials,

1916 Race Street,

Philadelphia,

PA 19103,

USA.

3   Definitions

For the purpose of this Standard, the following definitions apply.

3.1   Additive

A compound added to diesel fuel to improve either the performance or the storage stability or both.

3.2   Clear

Absence of moisture and suspended matter.

4   Requirements

4.1   GeneraI

4.1.1   The fuel shall be hydrocarbon oil derived from petroleum. This does not preclude the incorporation of small amounts of additives intended to improve some aspects of performance. The fuel shall be free from inorganic acid and from quantities of grit, fibrous material and other foreign matter likely to interfere with the operation of normal

equipment.

4.1.2   When Gasoil is tested in accordance with the methods of test given in Table 1, it shall be in compliance with the limiting requirements given in that Table.

4.2   Storage stability

When stored under conventional storage conditions for a period of 12 months after date of receipt, the fuel shall still comply with the requirements given in Table 1.

When the fuel is tobe stored for longer periods, the stability over a period exceeding 12 months shall be as agreed upon between the supplier and purchaser.

5   Packing and Marking

5.1   Packing

The condition of the containers, rail tankers and road tank vehicles shall be such as not to be detrimental to the quality of the fuel during normal transportation and storage. The containers shall be acceptably sealed and in addition shall conform to the Petroleum Act, Chapter 435 of the Laws of Zambia

5.2   Marking

5.2.1   The following information shall appear in legible and indelible marking on each container or in case of diesel fuel filled into bulk storage tanks, in the storage and consignment documents of each road tank wagon or rail tank wagon:

   (a)   the suppliers’ and receivers’ name and address;

   (b)   the type of fuel, i.e, “Automotive Gasoil” or ALow Sulphur Gasoil;

   (c)   the quantity in litres; and

   (d)   the batch/lot number.

5.2.2   The containers may also be marked with the Zambian Standard Certification Mark.

Note on the use of the Certification Mark

The Zambia Bureau of Standards is the owner of the registered certification mark shown below, the independent assurance that the product complies with the requirements of this Zambian Standard.

This certification mark may be used by manufacturers only under licence from the Bureau. Particulars of the conditions under which licences are granted may be obtained from the Director, ZambiaBureau of Standards, P.O. Box 50259, LUSAKA, 15101, Zambia.

ZS 369

Table 1
Requirements for automotive gasoil (diesel fuel)

Characteristics

 

Requirements

Test Methods

Specific Gravity, 15°C Appearance

 

0.820-0.870 Clear

ASTM D 1298 Visual

Colour, Max. Cetane Number,

 

3.5
46

ASTM D 1500 ASTM D 613

min. Cetane Index,

 

50

ASTM D 976

calc., min. Viscosity, at 40°C

 

2.00-5.50

ASTM D 445

cSt Cloud Point, °C,

 

4 5

ASTM D 2500

max. Sulphur, % mass

 

0 75

ASTM D

max.

 

2622/1552

 

Copper Corrosion 3 hrs at 100°C, max.
Carbon Residue, 10% Bottoms,

1 0.15

ASTM D 130

ASTM D 524

max.
Water, % Vol., max.

0.05

ASTM D 95

Sediment. % Vol., max.

0.01

ASTM D 1796

Ash, % Mass, max.

0.01

ASTM D 482

Flash Point PMCC, °C, min.

60 00

ASTM 93

Total Acidity, mg KOH/g, max.

1.00

ASTMD D 664

Distillation

at 360°C

90

ASTM D 86

Recovery, %, min.

   
 

from 240-

50

 

310°C

   

The requirements of low Sulphur Gasoli are as specified for Automotive Gasoil except for the Cetane index and the Sulphur content which are as indicated below:


Sulphur, % mass, max: 0.5 Cetane Index, min.: 40

6   Methods of Test

For all characteristics, use the applicable method listed in column 3 of Table 1.

7   Sampling

7.1   Sampling from storage tanks

For the purposes of this standard, all sampling shall be carried out in accordance with the relevant sections of ZS 396 and additionally as detailed in 7.2.

7.2. Sampling from fuel lines

7.2.1   Sampling cans. Sampling cans shall be of 5 litres capacity.

Note

Attention is drawn to the fact that sampling cans will need to comply with the statutory safety requirements for the classification, packaging and labeling of dangerous substances.

7.2.2   Preparation of cans. A stock of cans shall be kept solely for the purpose of taking fuel samples. Before use, all cans shall be checked to ensure they are sound and free from leaks. A fuel-resistant sealing washer in good condition shall be in position in the cap.

7.2   3 Procedure. From the discharge point, 5 litres of the fuel to be tested shall be carefully

drawn into a 5 litres can using a clean dry funnel. The screw cap shall be fully tightened and the can checked to ensure that there are no leaks.

Note

If more than 5 litres are needed, the operation should be repeated immediately and before the pump has been used for any other purpose.

7.2.4 Labeling and transport. Full and legible information relating to the source of the sample shall be attached to the can in such a manner that it will not easily become detached subsequently.

Note 1

If required, the sample may be sealed and labeled to maintain its legal integrity.

Note 2

If the sample has to be sent to the laboratory by public transport, it will be necessary to comply with the general regulations covering transportation of flammable materials, where appropriate, and with the requirements of the transport authority concerned. Information on the appropriate procedures and type of packaging required should be obtained from the relevant transport authority involved.

ZAMBIA BUREAU OF STANDARDS

Zambia Standard ZS 380

Illuminating Kerosine—Specification

1   Scope

This Zambian Standard specifies requirements for Illuminating Kerosene for both domestic and industrial application.

2   Normative Reference

In this Standard, reference has been made to the following standards:

ASTM D 86 Test Method for Distillation of Petroleum Products.

ASTM D 130 Test Method for Detection of Copper Corrosion from Petroleum Products by the Copper Strip Tarnish.

ASTM D 156 Test Method for Saybolt Colour of Petroleum Products (Saybolt Chronometer Method).

ASTM D 1266 Test Method for Sulphur in Petroleum Products (Lamp

Method).

ASTM D 1298Test Method for Density, Relative Density (Specific Gravity) or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method.

ASTM D 2709 Test Method for Water and Sediment Determination in

Distillate Fuels by Centrifuge.

IP 10 Test Method for Determination of Kerosene Burning

Characteristics B 24 Hour Method.

IP 57   Test Method for Smoke Point.

IP 170   Test Method for Flash Point B Abel Apparatus

(Kerosene)

ZS 372   Transportation of Petroleum Products: Operational

Requirements for Road Tank Vehicles - Code of Practice.

ZS 396   Method of Sampling Petroleum and Petroleum Products

Part 1: Manual Sampling of Liquid Hydrocarbons

Note 1 ASTM: American Society for Testing and Materials.

Note 2 IP: Institute of Petroleum.

3   Definitions

For the purpose of this Standard, the following definitions apply:

3.1   Additive: A compound added to illuminating kerosene for identification or to improve

performance or storage stability.

3.2   Marketable: Acceptable smell for comfortable handling.

4   Requirements

4.1   General

4.1.1   The illuminating kerosene shall be hydrocarbon oil derived from petroleum. This does not preclude the incorporation of small amounts of additives intended to improve some aspects of performance. The kerosene shall be free from inorganic acid and from quantities of grit, fibrous material and other foreign matter likely to interfere with the operation of normal equipment.

4.1.2   When tested in accordance with the methods of test given in Table 1, illuminating kerosene shall be in accordance with the limiting requirements given in the table.

4.1.3   On Visual Inspection at ambient temperature, the illuminating kerosene shall be clear, bright and free from solid matter.

4.2   Storage stability

4.2.1   After conventional storage under normal conditions for a period of 6 months after the date of rec'eipt, the illuminating kerosene shall still comply with all the requirements of this Standard (other than the requirements for potential gum content).

4.2.2   In the case of illuminating kerosene that is to be stored for longer than 6 months, the storage stability of the fuel shall be such that in addition to complying with the requirements of

4.2.1,   it shall comply with the gum content requirements as are agreed upon between the supplier and purchaser.

5   Packing and Marking

5.1   Packing

The condition of the containers, rail tankers and road tank vehicles into which the illuminating kerosene is filled shall be such as not to be detrimental to the quality of the fuel during normal transportation and storage. The containers shall be acceptably sealed and in addition shall conform to the Petroleum Act, Chapter 435 of the Laws of Zambia.

5.2   Marking

5.2.1   The following information shall appear in legible and indelible marking on each container or in the case of illuminating kerosene filled into bulk storage tanks, with the storage and consignment documents of each road tanker or rail wagon as stipulated in ZS 372:

   (a)   the manufacturer’s name and address;

   (b)   the type of fuel as stipulated under the UN Code;

   (c)   the hazards involved in handling and transpo’rtation;

   (d)   the Transport Emergency Card (Tremcard); and

   (e)   the batch/lot number

5.2.2   The containers may also be marked with the Zambian Standard Certification mark.

Note on the use of Certification Mark

The Zambia Bureau of Standards is the owner of the registered certification mark shown below, the independent assurance that the product complies with the requirements of this Zambian Standard.

This certification mark may be used by manufacturers only under licence from the Bureau. Particulars of the conditions under which licences are granted may be obtained from the Director, ZambiaBureau of Standards, P.O. Box 50259, LUSAKA, 15101, Zambia.

ZS 380

6   Test Methods

For all characteristics, the test methods listed in column 3 of Table 1 shall apply.

7.  Sampling

7.1   Sampling from storage tanks

For the purposes of this Zambian Standard all sampling shall be carried out in accordance with the relevant procedures of ZS 396and, additionally, as detailed in 7.2

Table 1.
Requirements for illuminating kerosene.

Characteristic

Requirement

Test Method

Specific gravity @15°C, max.

0.82

ASTM D 1298

Appearance

Bright and cleaar

Visual

Odour

Maretable

see 3.2

Saybolt colour, min.

+20

ASTM D 156

Total Sulphur, % mass, min.

0.20

ASTM D 1266

Copper Corrosion, 3 h at 100°C max

1

ASTM D 130

Flash Point, Closed Cup, Abel Pensky, °C nun.

38

IP 170

Smoke Point, mm, min.

20

IP 57

Char Value, mg/kg, max.

15

IP 10

Water and Sediments, % vol, max.

0.05

IP 74/82

End boiling point, °C 300

ASTM D 86

Note


Domestic kerosene shall be dyed green while industrial kerosene shall be colourless.

 

7.2   Sampling fromfuel lines

7.2.1   Sampling cans of 5 litres and 1 litre capacity. The construction of the cans shall comply with the appropriate safety requirements for cans that are to hold highly flammable material. They shall be provided with screw caps incorporating a petroleum resistant washer in good condition. A stock of cans shall be kept solely for the purpose of taking illuminating kerosene samples.

7.2.2   Preparation of cans. New cans shall be rinsed with illuminating kerosene before being used, to remove any residual traces of oil left during manufacturing operations, and then allowed to dry. Before use, all cans shall be checked to ensure that they are sound and free from leaks.

7.2.3   Sampling procedure. From the pump nozzle, 5 litres of illuminating

kerosene shall be drawn carefully into a cool 5 litres can using a clean dry funnel. Immediately afterwards, this sample shall be decanted carefully into the requisite number of 1 litre cans, using a funnel, filling the cans within 15 mm of the brim.

If more than 5 litres are needed, the operation shall be repeated immediately and before the pump has been used for any other purpose. The screw caps shall be tightened fully and the cans checked to ensure that there are no leaks.

The sampling procedure shall not be carried out in direct sunlight.

Note 1 If carried out in direct sunlight, changes in fuel quality may occur.

7.2.4   Storage, labeling and transport. Samples shall be kept in a cool place and well ventilated although it is not necessary to keep them refrigerated.

Full and legible information relating to the source of the sample shall be attached to the can in such a manner that it will not easily become detached subsequently.

Note 1.If required, the sample may be sealed and labeled to maintain its integrity.

2. If the sample has to be sent to a laboratory by public transport, it will b e necessary to comply with the general regulations covering transportation of flammable materials and with the requirements of the transport authority concerned. Information on the appropriate procedures and the type of packaging required should be obtained from the transport authority involved

ZAMBIA BUREAU OF STANDARDS

Zambia Bureau of Standards ZS 395

Unleaded Petrol (Gasoline) for MotorVehicles—Specification

1. Scope

This Zambian Standard specifies requirements for unleaded gasoline (petrol) for motor vehicles.

2. Test and Sampling Methods

In this Standard, reference has been made to the following methods:

ASTM D 86 Test Method for Distillation of Petroleum Products;

ASTM D 130 Test Method for Detection of Copper Corrosion from Petroleum Products by the Copper Strip Tarnish Test;

ASTM D 323 Test Method for Vapour Pressure of Petroleum Products (Reid Method);

ASTM D 381 Test Method for Existent Gum in Fuels by Jet Evaporation;

ASTM D 525 Test Method for Oxidation Stability of Gasoline (Induction Period Method);

ASTM D 873 Test Method for Oxidation Stability of Aviation Fuels (Potential Residue Method);

ASTM D 1250 Guide for Petroleum Measurement Tables (Description only; tables published separately in 12 volumes);

ASTM D1266 Test Method for Sulphur in Petroleum Products (Lamp Method);

ASTM D1298 Test Method for Density, Relative Density (Specific

Gravity) or API Gravity of Crude Petroleum and Liquid Petroleum Products by Hydrometer Method;

ASTM D 2699 Test Method for Knock Characteristics of Motor Fuels by the Research Method;

ASTM D2700 Test Method for Knock Characteristics of Motor and Aviation Fuels by the Motor Method;

ASTM D 3116 Test Method for Trace Amounts of Lead in Gasoline;

ASTM D 3120 Test Method for trace quantities of sulphur in light

liquid petroleum hydrocarbons by oxidative microcoulometry;

ASTM D 3237 Test Method for lead in gasoline by atomic absorption spectroscopy;

ASTM D 3242 Test Method for total acidity in aviation turbine fuel;

ASTM D 3348 Test Method for rapid field test for trace lead in unleaded gasoline (colorimetric method);

ASTM 3831 Test Method for manganese in petrol by atomic absorption spectrometry;

[Ins by para 2(a) of SI 2 of 2012.]

ASTM D 4052 Test Method for density and relative density of liquids by digital density meter;

ASTM D 4057 Standard Practice for manual sampling of petroleum and petroleum products;

ASTM D 4177 Standard Practice for automatic sampling of petroleum and petroleum products;

ASTM D 4815 Test Method for determination of C, to C4 Alcohols and

Methyl tertiary butyl ether (MTBE) in gasoline by gas chromatography;

ASTM D 4953 Test Method for vapour pressure of gasoline and Gasoline-oxygenate blends;

ASTM D 5059 Test Method for lead in gasoline by X-ray spectroscopy;

IP 243 Determination of sulphur content of petroleum products

-   Wickbold Oxy-hydrogen Method

IP 336 Petroleum Products - determination of sulphur content

-   Energy Dispersive X-ray Fluorescence Method

ZS 396 Sampling Petroleum Products - Part 1: Manual Sampling of Liquid Hydrocarbons

3. Definitions

For the puipose of this standard, the following definitions apply:

3.1   Acceptable: Acceptable to the parties concluding the purchase contract, in compliance with this Zambian Standard Order.

[Para 3.1 subs by para 2(b) of SI 2 of 2012.]

3.2   Additive: A compound added to gasoline to improve either the performance of the gasoline or its storage stability or both.

Note. Such compounds include alcohols and certain other

oxygenated compounds.

3.3 ASTM method: A test method published by the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103, USA.

[Para 3.3 rep by para 2(c); para 3.4 renumbered as para 3.3 para 2(d) of SI 2 of 2012.]

3.4   ZS: A Zambian Standard published by the Zambia Bureau of Standards;

[Para 3.4 ins by para 2(e) of SI 2 of 2012.]

3.5   IP —Institute of Petroleum, 61 New Cavendish Street, London WIM 8 AR, England.

3.6   IP method:   A test method published by the Institute of Petroleum, 61 New Cavendish Street, London, W1M 8AR, England.

4. Requirements

4.1   General

4.1.1   The gasoline shall be a hydrocarbon fuel to which additives may have been added to improve its performance or its storage stability (or both) and shall be suitable for use in spark ignition internal-combustion engines other than aviation piston engines. The gasoline may also contain small quantities of harmless colouring materials to give it a distinctive appearance.

4.1.2   The oxygen content of petrol incorporating ethanol, higher Alcohols and other oxygenated compounds shall not exceed 3.7% (m/m).

4.1.3   The product when tested in accordance with the methods of test given in Table 1 shall comply with all the limiting requirements given in that table. At 20_C or at ambient temperature (whichever is higher), the product shall be clear and free from visible water, sediment, suspended matter and any other contaminant that can cause malfunctioning of equipment designed to use this type of fuel.

4.1.4 Acceptable Additives for the purposes of this Zambian Standard, the following are the acceptable octane enhancers:

(a)   Methylcyclopent adienyl manganese tricarbonyl (MMT);

(b)   Ferrocene; or

(c)   Alcohol.

[Para 4.1.4 ins by para 2(f) of SI 2 of 2012.]

4.2   Storage Stability

4.2.1   After conventional storage under normal conditions for a period of 6 months after the date of receipt, the gasoline shall still comply with all the requirements of this standard (other than the requirements for potential gum content).

4.2.2   In the case of gasoline that is to be stored for longer than 6 months, the storage stability of the petrol shall be such that, in addition to complying with the requirements of 4.2.1, the gasoline complies with such other requirements as are agreed upon (see Annex A).

TABLE 1.
Requirement for Unleaded Petrol(Gasoline)

Characteristic

Requirement

Test method

Octane Rating

   

(a) Research Octnae number (RON), min

91

ASTM D 2699

(b) Motor Octane Number (MON), min

81

ASTM D 2700

(c) Motor Octane number (MON) for

83

ASTM D 2700

blends containing more than 2% (v) /v)

   

Colour

Yellow

Visual

Density at 20°C, kg/1

0.710-0.785

ASTM D 1298 ASTM D 4052

Distillation


(a) Temperature, °C for

   

10% (v/v) evaporated, max.

65

 

50% (v/v) evaporated

77-115

ASTM D 86

 

90% (v/v) evaporated, max
(b)   End boiling point, oC, max
(c)   Residue, % (v/v), max.
(d)   Evaporated to 70°C (E70), % (v/v)

185
215
2.0
Report

   

Reid Vapour Pressure (RVP). kPa, max.

45-75

see 6.1

 

Flexible Volatility Index (FVI =RVP +0.7 E70 (a) FVI (Summer '), max

89

see 6.2

 

(b) FVI (winter1), max.

94

   

Lead content g Pb/L, max

0.02

ASTM D 3116, D 5059, D 3237, D 3348

 

Induction Period, minute, min

360

ASTM D 525

 

Existent Gum Content, mg/100 mL, max

4

ASTM D 381

 

Pontial Gum (2.5 hr at 100°C), mg/1 OOmL, max

4

ASTM D 873

 

Manganese content, mg Mn/, max

25

ASTM D 3831, ASTM D3237

 

Iron, mg Fe/I.

Report

ASTM D 3831, ASTM D3237

 
     

[Para 4 Table 1 am by para 2(g) of SI 2 of 2012.]

Suphur Content, % (m/m), max.

0.10

ASTM D 1266, D 3120.IP 243

Copper Corrosion, 3 hrs at 50°C, max

1

ASTM D 130

Total Acidity2), mg KOH/g, max

0.003

ASTM D 3242

Oxygen Content3), % (m/m), max

3.7

ASTM D 4815

(1)   Summer=September to 30 April (inclusive)
Winter = 1 May to 31 August (inclusive)
(2)   Applicable to fuels only containing oygenates
(3)   Any alcohol blended into the fuel shall contain a minimum of 85% (m/m) ethanol with the balnce i-propanol and n-propanol, and only trace quantities of other alcohols.
3.7% (m/m) oxygen = approximately 20% (v/v) MTBE = appromatley 9.5%(v/v) ethanol

Notes
1. For Octane Rating only one of the three parametere needs to be satisfied.
2. Ethers containing five or more carbon atoms molecule may be included up

Characteristic Requirement Test method '

to a maximum concentration as indicated in the standard.The oxygen content of the blend will be determined by method ASTM D 4815 (MTBE) and such othermethods that may be developed for other C5 esters.

1. ASTM D 1250 / IP 200 (Standard guide for petroleum measurement tables) should be used for correction of densites at 15°C and 20°C respectively

Packing and Marking

4.3   Packaging

The condition of the drums and bulk tankers into which the petrol is filled shall be such as not to be detrimental to the quality of the fuel during normal transportation and storage. Drums and containers shall be acceptably sealed and in addition shall conform to the Petroleum Act, Chapter 435 of the Laws of Zambia.

4.4   Marking

The following information shall appear in legible and indelible marking on each container or in the case of gasoline filled into bulk storage tanks, in the storage and consignment documents of each road tanker or rail wagon:

   (a)   the suppliers’ and receivers’ name and address;

   (b)   the type of fuel, i.e. Unleaded Petrol (Gasoline);

   (c)   the quantity in litres; and

   (d)   the batch/lot number.

5. Method of Test

For all characteristics, use the applicable method listed in column 3 of Table

5.1. Reid Vapour Pressure

5.1.1   When testing fuels containing no alcohol, use test method ASTM D323.

5.1.2   When testing fuel blends containing oxygenates in the form of alcohols or alcohol/ether mixtures, use test method ASTM D4953.

Note: When alcohol is present in fuel, the water introduced when test method

ASTM D 323 or IP 69 is used will extract some of the alcohol, causing low Reid Vapour Pressure values to be obtained.

5.2   Flexible Volatility Index (FVI)

The flexible volatility index is another parameter that characterises the

volatility properties of petrol, and is calculated using the formula:

FVI = RVP + 0.7 E70

where RVP is the vapour pressure in kilopascals; and E70 is the percentage of petrol, by volume, evaporated to 70°C

6. Sampling

6.1   Sampling from storage tanks

For the purposes of this Zambian Standard all sampling shall be carried out in accordance with the relevant procedures of ZS 396 Part 1 and, additionally, as detailed in 7.2.

Note: Attention is drawn to the special precautions needed for

samples for the determination of Reid Vapour Pressure.

6.2   Sampling from petrol pumps

6.2.1   Sampling cans of 5 litres and 1 litre capacity. The construction of the cans shall comply with the appropriate safety requirements for cans that are to hold highly flammable material. They shall be provided with screw caps incorporating a petroleum resistant washer in good condition. A stock of cans shall be kept solely for the purpose of taking gasoline samples.

6.2.2.Preparation of cans. New cans shall be rinsed with gasoline before being used, to remove any residual traces of oil left during manufacturing operations, and then allowed to dry. Before use, all cans shall be checked to ensure that they are sound and free from leaks.

6.2.3   Sampling procedure. From the pump nozzle, 5 litres of gasoline shall be drawn carefully into a cool 5-litre can using a clean dry funnel. Immediately afterwards, this sample shall be decanted carefully into the requisite number of 1 litre cans, using a funnel, filling the cans within 15 mm of the brim.

If more than 5 litres are needed, the operation shall be repeated immediately and before the pump has been used for any other purpose. The screw caps shall be tightened fully and the cans checked to ensure that there are no leaks.

The sampling procedure shall not be carried out in direct sunlight.

Notes 1. If carried out in direct sunlight, changes in fuel quality,

especially octane level, may occur.

2. A quantity of 1 litre is sufficient for the determination of octane

number and certain other tests but it is advisable to provide each laboratory with 2 litres of sample in case further work is needed; it is essential that these 2 litres be of identical material.

6.2.4   Storage, labeling and transport. Samples shall be kept in a cool place although

it is not necessary to keep them refrigerated.

Notes 1. If left in direct sunlight there is a danger that the cans will balloon.

Full and legible information relating to the source of the sample shall be attached to the can in such a manner that it will not easily become detached subsequently.

2. If required, the sample may be sealed and labeled to maintain its legal integrity.

3. If the sample has to be sent to a laboratory by public transport, it will be necessary to comply with the general regulations for the transportation of flammable materials and with the requirements of the transport authority concerned. Information on the appropriate procedures and the type of packaging required should be obtained from the transport authority involved.

ANNEX A

(Normative)

Notes to purchasers

A. 1 The following requirement shall be agreed between the supplier and thepurchaser:

When the petrol has been stored for a period exceeding 6 months, for any additional requirements for storage stability (see 4 2.2)

Annex B

(Informative)

B. 1 Materials Compatibility

It is recognised and accepted that there can be interactions (in the fuel system) between the materials used in the manufacturing and assembly of motor vehicles fuel systems, and the fuel supplied such that malfunctioning of components can occur. In order to minimise such risks, fuel suppliers and motor manufacturers have agreed that:

   (a)   the fuels supplied will, as far as is within reason and technically possible, be compatible with the fuel system component materials that have hitherto been used;

   (b)   the vehicle fuel system component materials will as far as is within reason and technically possible, be compatible with the fuels that have hitherto been supplied; and

   (c)   any significant changes to the fuel composition or to the fuel system component materials will be subject to test before introduction, to prove suitability for the purpose intended.

B.2   Deposit Control Additive

It is recommended that petrol that complies with the requirements of this standard contain a deposit control additive. Pumps dispensing such petrol should be so marked.

ANNEX C

(Informative)

W ater Tolerance T est

C. 1 Scope

Blends of petrol/alcohol/oxygenates can from time to time cause problems with wet/ dry corrosion. The water tolerance test determines the ability of such blends to retain water in solution or in a stable suspension at the specified temperature to which they are likely to be exposed in use.

C.2 Apparatus and materials

C.2.1 Glass measuring cylinder, of capacity 100 ml and fitted with a ground glass stopper

C.2.2 Micropipette (complete with disposable tip), of suitable capacity and capable of accurately dispensing a volume of 200 ul.

C.2.3 Water, distilled or de-ionised.

C.3 Procedure

Note— Conduct the test at a temperature of 20°C _± 2°C

C.3.1 Rinse the measuring cylinder (including its stopper) with the test sample and allow it to drain.

C.3.2 Fill the measuring cylinder up to the 100 ml graduation mark with the test sample and, using the micropipette, add 200 _1 of the water.

C.3.3   Stopper the measuring cylinder, shake vigorously for 1 min, and then inspect the test specimen for signs of phase separation.

C .3 4 Report the sample as having passed the test if no sign of phase separation or persistent haze is visible.

ANNEX D

(Informative)

Alcohol Content Test

D.l   Scope

There may be need from time to time in the field to establish whether or not a sample

of petrol contains alcohol The alcohol content test is simple and quick and does not require

sophisticated equipment or specialist operator skills

D.2 Apparatus and materials

Ensure that all glassware used is (e.g. cleaned by flushing twice with acetone) and dry.

D.2.1 Glass mixing cylinder, graduated in millilitres and fitted with a ground glass stopper. The cylinder is capable of accepting a total volume of at least 125 ml with the stopper in place

D.2 2 Glass measuring cylinder, of capacity 100 ml

D.2.3 Ethylene glycol, analytical reagent grade, and that may contain, if so desired, a suitable concentration of a water soluble dye (e.g. 0 02 g of methyl violet per litre).

D 3 Procedure

D.3.1 Fill the mixing cylinder to exactly the 25 ml graduation mark with the

ethylene glycol (taking care not to wet the wall of the cylinder with the ethylene glycol) and, using the measuring cylinder, add 100 ml of the petrol under test.

D.3.2 Stopper the mixing cylinder, invert it and shake it back and forth 25 times in 15 s using strokes each if length approximately 25 cm.

D 3.3 Immediately thereafter, place the mixing cylinder on a vibration-free surface; allow the contents to settle undisturbed for 5 min, and then record, to the nearest 0.2 ml, the volume of the layer of ethylene glycol and alcohol at the bottom of the cylinder.

D.3 4 Calculate the difference between the volume of the layer of ethylene glycol and alcohol and the volume of the ethylene glycol used for extraction (i.e. 25 ml), and report it as the percentage by volume of alcohol in the petrol.

ZAMBIA BUREAU OF STANDARDS

Zambian Standard ZSEN 197: 2007

Cement—Part 1: Composition, specifications and conformity criteria for common Cements 1.Scope

EN 197-1 defines and gives the specifications of 27 distinct common cement products and their constituents. The definitions of each cement includes the proportions in which the constituents are to be combined to produce these distinct products in a range of six strength classes. The definition also includes requirements the constituents have to meet and the mechanical, physical and chemical requirements of the 27 products and strength classes. EN 197-1 also states the conformity criteria and the related rules. Necessary durability requirements are also given.

Notes 1. In addition to the specified requirements, an exchange of additional information between the cement manufacturer and user may be helpful. The procedures for such an exchange are not within the scope of EN 197-1 but should be dealt with in accordance with national standards or regulations or may be agreed between the parties concerned.

2. The word “cement” in EN 197-1 is used to refer only to common cements unless otherwise specified.

2   Normative References

EN 197-1 incorporates by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to EN 197 only when incorporated in it by amendment or revision. For undated references the latest edition of the publication referred to applies.

EN 196 - 1, Methods of testing cement - Part 1: Determination of strength;

EN 196-2, Methods of testing cement - Part 2: Chemical analysis of cement;

EN 196-3, Methods of testing cement - Part 3: Determination of setting time and soundness; EN 196 - 5, Methods of testing cement - Part 5: Pozzolanicity test for pozzolanic cements;

EN 196-6, Methods of testing cement - Part 6: Determination of fineness;

EN 196-7, Methods of testing cement - Part 7: Methods of taking and preparing samples of cement;

EN 196-21 Methods of testing cement - Part 21: Determination of the chloride, carbon dioxide and alkali content of cement;

EN 197-2, Cement - Part 2: Conformity evaluation;

prEN 13639: 1999, Determination of total organic carbon content in limestone;

EN 451-1, Method of testing fly ash - Part 1: Determination of free calcium oxide content;

EN 933-9, Tests for geometrical properties of aggregates - Part 9: Assessment of fines - Methylene blue test; andEN 934-2, Admixtures for concrete, mortar and grout - Part 2: Concrete admixtures - Definitions and requirements.

°EN 196-21 is currently being incorporated into EN 196-2.

ISO 9277, Determination of the specific surface area of solids by gas adsorption using the BET method.

3   Cement

For the purposes of EN 197-1, the following definitions apply:

3.1. Reactive calcium oxide (CaO)

that fraction of the calcium oxide which under normal hardening conditions can form calcium silicate hydrates or calcium alumínate hydrates;

Note To evaluate this fraction the total calcium oxide content (see EN 196-2) is reduced by the fraction corresponding to calcium carbonate (CaC03). Based on the measured carbon dioxide (C02) content (see EN 196-21), and the fraction corresponding to calcium sulfate (CaS04). Based on the measured sulfate (S03) content (see EN 196-2) after substraction of the S03 taken up by alkalis.

3.2. Reactive silicon dioxide (SiOJ

that fraction of the silicon dioxide which is soluble after treatment with hydrochloric acid (HC1) and with boiling potassium hydroxide (KOH) solution;

Note The quantity of reactive silicon dioxide is determined by subtracting from the total silicon dioxide content (see EN 196-2) that fraction contained in the residue insoluble in hydrochloric acid and potassium hydroxide (see EN 196-2). both on a dry basis.

3.3. Main constituent

specially selected inorganic material in a proportion exceeding 5 % by mass related to the sum of all main and minor additional constituents;

3.4. Minor additional constituent

specially selected inorganic material used in a proportion not exceeding a total of 5 % by mass related to the sum of all main and minor additional constituents;

3.5. Type of common cement

one of the 27 products (see Table 1) in the family of common cements;

3.6. Strength class of cement class of compressive strength;

3.7. Autocontrol testing

continual testing by the manufacturer of cement spot samples taken at the point(s) of release from the factory/depot;

3.8. Control period

means the period of production and dispatch identified for the evaluation of the autocontrol test results;

3.9. Characteristic value

means the value of a required property outside of which lies a specified percentage, the percentile Pk, of all the values of the population

3.10. Specified characteristic value

means the characteristic value of a mechanical, physical or chemical property which in the case of an upper limit is not to be exceeded or in the case of a lower limit is, as a minimum, to be reached;

3.11. Single result limit value

means the value of a mechanical, physical or chemical property which - for any single test result

-   in the case of an upper limit is not to be exceeded or in the case of a lower limit is, as a minimum, to be reached;

3.12. Allowable probability of acceptance CR

for a given sampling plan, means the allowed probability of acceptance of cement with a characteristic value outside the specified characteristic value;

3.13. Sampling plan

means the specific plan which states the (statistical) sample size(s) to be used, the percentile Pk and the allowable probability of acceptance CR;

3.14. Spot sample

means the sample taken at the same time and from one and the same place, relating to the intended tests. It can be obtained by combining one or more immediately consecutive increments (see EN

196-7).

4   Cement

Cement is a hydraulic binder, i.e. a finely ground inorganic material which, when mixed with water, forms a paste which sets and hardens by means of hydration reactions and processes and which, after hardening, retains its strength and stability even under water.

Cement conforming to EN 197-1, termed CEM cement, shall, when appropriately batched and mixed with aggregate and water, be capable of producing concrete or mortar which retains its workability for a sufficient time and shall after defined periods attain specified strength levels and also possess long-term volume stability.

Hydraulic hardening of CEM cement is primarily due to the hydration of calcium silicates but other chemical compounds may also participate in the hardening process, e.g. aluminates. The sum of the proportions of reactive calcium oxide (CaO) and reactive silicon dioxide (Si02) in GEM cement shall be at least 50 % by mass when the proportions are determined in accordance with EN 196-2.

CEM cements consist of different materials and are statistically homogeneous in composition resulting from quality assured production and material handling processes The link between these production and material handling processes and the conformity of cement to EN 197-1 is elaborated in EN 197-2.

Note There are also cements whose hardening is mainly due to other compounds, e.g. calcium alumínate in calcium alumínate cement.

5   Constituents

5.1   General

The requirements for the constituents specified in 5.2 to 5.5 shall be determined in principle in accordance with the test methods described in EN 196 unless otherwise specified.

5.2   Main constituents

5.2.1   Portland cement clinker (E)

Portland cement clinker is made by sintering a precisely specified mixture of raw materials (raw meal, paste or slurry) containing elements, usually expressed as oxides, CaO, Si02, A1203, Fe203 and small quantities of other materials. The raw meal, paste or slurry is finely divided, intimately mixed and therefore homogeneous.

Portland cement clinker is a hydraulic material which shall consist of at least two-thirds by mass of calcium silicates (3CaO . Si02 and 2CaO . Si02), the remainder consisting of aluminium and iron containing clinker phases and other compounds. The ratio by mass (Ca0)/(Si02) shall be not less than 2.0. The content of magnesium oxide (MgO) shall not exceed 5.0 % by mass.

5.2.2   Granulated blastfurnace slag (S)

Granulated blastfurnace slag is made by rapid cooling of a slag melt of suitable composition, as obtained by smelting iron ore in a blastfurnace and contains at least two-thirds by mass of glassy slag and possesses hydraulic properties when suitably activated.

Granulated blastfurnace slag shall consist of at least two-thirds by mass of the sum of calcium oxide (CaO), magnesium oxide (MgO) and silicon dioxide (Si02) The remainder contains aluminium oxide (Al203) together with small amounts of other compounds. The ratio by mass (CaO + MgO)/(SiOz) shall exceed 1.0

5.2.3   Pozzolanic material (P, Q)

5.2.3.1General

Pozzolanic materials are natural substances or industrial pozzolanas, siliceous or silico- aluminous, or a combination thereof. Although fly ash and silica fume have pozzolanic properties, they are specified in separate clauses (see 5.2.4 and 5.2.7).

Pozzolanic materials do not harden in themselves when mixed with water but, when finely ground and in the presence of water, they react at normal ambient temperature with dissolved calcium hydroxide (Ca (OH) 2) to form strength-developing calcium silicate and calcium alumínate compounds. These compounds are similar to those which are formed in the hardening of hydraulic materials. Pozzolanas shall consist essentially of reactive Si02 and Al203. The remainder contains Fe203 and other oxides. The proportion of reactive Ca03) is negligible. The reactive Si02 content shall be not less than 25 % by mass.

Pozzolanic materials shall be correctly prepared, i.e. selected, homogenized, dried and comminuted, depending on their state of production or delivery.

5.2   3.2 Natural pozzolana (P)

Natural pozzolanas are usually substances of volcanic origin or sedimentary rocks with suitable chemical and mineralogical composition and shall conform to 5.2.3.1

5.2.3.3   Natural calcined pozzolana (Q)

Natural calcined pozzolanas are materials of volcanic origin, clays, shales or sedimentary rocks, activated by thermal treatment and shall conform to 5.2.3.1.

5.2.4. Fly ashes (V, W)

5.2.4.1   General

Fly ash is obtained by electrostatic or mechanical precipitation of dust-like particles from the flue gases from furnaces fired with pulverised coal. Ash obtained by other methods shall not be used in cement that conforms to EN 197-1.

Fly ash may be siliceous or calcareous in nature. The former has pozzolanic properties; the latter may have, in addition, hydraulic properties The loss on ignition of fly ash determined in accordance with EN 196-2, but using an ignition time of 1 h, shall not exceed 5.0 % by mass.

Fly ash with loss on ignition of 5.0 % to 7.0 % by mass may also be accepted, provided that particular requirements for durability, especially frost resistance, and for compatibility with admixtures are met according to the appropriate standards and/or regulations for concrete or mortar in the place of use. In the case of fly ash with a loss on ignition between 5.0 % and 7.0 % by mass the maximum limit, 7.0 %, shall be stated on the packaging and/or the delivery note of the cement.

5.2.4.2   Siliceous fly ash (V)

Siliceous fly ash is a fine powder of mostly spherical particles having pozzolanic properties. It consists essentially of reactive silicon dioxide (Si02) and aluminium oxide (A1203). The remainder contains iron oxide (Fe203) and other compounds.

5.2.4.3   Calcareous fly ash (W)

Calcareous fly ash is a fine powder, having hydraulic and/or pozzolanic properties. It consists essentially of reactive calcium oxide (CaO), reactive silica (Si02) and aluminium oxide (A1203). The remainder contains iron oxide (Fe203) and other compounds. The proportion of reactive calcium oxide shall not be less than 10.0%bymass. Calcareous fly ash containing between 10.0 and 15.0 % mass of reactive calcium oxide shall contain not less than 25.0 % by mass of reactive silica.

Adequately ground calcareous fly ash containing more than 15.0 % by mass of reactive calcium oxide, shall have a compressive strength of at least 10.0 MPa at 28 days when tested in accordance with EN 196 - 1. Before testing, the fly ash shall be ground and the fineness, expressed as the proportion by mass of the ash retained when wet sieved on a 40 nm mesh sieve, shall be between 10 % and 30 % by mass. The test mortar specimens shall be demoulded 48 h after preparation and then cured in a moist atmosphere of relative humidity of at least 90 % until tested.

The expansion (soundness) of calcareous fly ash shall not exceed 10 mm when tested in accordance with EN 196-3 using a mixture of 30 % by mass of calcareous fly ash ground as described above and 70 % by mass of a CEM I cement conforming to EN 197-1.

Note If the sulphate (503) content of the fly ash exceeds the permissible upper limit for the sulphate content of the cement then this has to be taken into account for the manufacture of the cement by appropriately reducing the calcium sulphate- containing constituents.

5.2.5   Burnt shale (T)

Burnt shale, specifically burnt oil shale, is produced in a special kiln at temperatures of approximately 800 °C. Owing to the composition of the natural material and the production process, burnt shale contains clinker phases, mainly dicalcium silicate and monocalcium aluminate. It also contains, besides small amounts of free calcium oxide and calcium sulphate, larger proportions of pozzolanically reacting oxides, especially silicon dioxide. Consequently, in a finely ground state burnt shale shows pronounced hydraulic properties like Portland cement and in addition pozzolanic properties.

Adequately ground burnt shale shall have a compressive strength of at least 25.0 MPa at 28 days when tested in accordance with EN 196 - 1. The test mortar shall be prepared with finely ground burnt shale instead of cement. The mortar specimens shall be demoulded 48 h after preparation and cured in a moist atmosphere of relative humidity of at least 90 % until tested.

The expansion (soundness) of burnt shale shall not exceed 10 mm when tested in accordance with EN 196-3 using a mixture of 30 % by mass of ground burnt shale and 70 % by mass of a CEM I cement conforming to EN 197-1.

Note If the sulfate (S03) content of the burnt shale exceeds the permissible upper limit for the sulfate content of the cement then this has to be taken into account for the manufacture of the cement by appropriately reducing the calcium sulfate-containing constituents.

5.2.6   Limestone (L, LL)

Limestone shall meet the following requirements:

   (a)The calcium carbonate (CaC03) content calculated from the calcium oxide content shall be at least 75 % by mass.

   (b)   The clay content, de/ermined by the methylene blue test in accordance with EN 933-9,

shall not exceed 1.20 g/100 g. For this test the limestone shall be ground to a fineness of approximately 5000 cm2/g determined as specific surface in accordance with EN

196-6.

   (c)   The total organic carbon (TOC) content, when tested in accordance with prEN 13639: 1999, shall conform to one of the following criteria:

-   LL: shall not exceed 0.20 % by mass;

-   L: shall not exceed 0.50 % by mass.

5.2.7 Silica fume (D)

Silica fume originates from the reduction of high purity quartz with coal in electric arc furnaces in the production of silicon and ferrosilicon alloys and consists of very fine spherical particles containing at least 85 % by mass of amorphous silicon dioxide.

Silica fume shall meet the following requirements:

   (a)The loss on ignition shall not exceed 4.0 % by mass determined in accordance with EN

196-2 but using an ignition time of 1 h.

   (b)The specific surface (BET) of the untreated silica fume shall be at least 15.0 m2/g when tested in accordance with ISO 927?.

For intergrinding with clinker and calcium sulfate the silica fume may be in its original state or compacted or pelletised (with water).

5.3   Minor additional constituents

Minor additional constituents are specially selected, inorganic natural mineral materials, inorganic mineral materials derived from the clinker production process or constituents as specified in 5.2 unless they are included as main constituents in the cement.

Minor additional constituents, after appropriate preparation and on account of their particle size distribution, improve the physical properties of the cement (such as workability or water retention). They can be inert or have slightly hydraulic, latent hydraulic or pozzolanic properties. However, no requirements are set for them in this respect.

Minor additional constituents shall be correctly prepared, i.e. selected, homogenised, dried and comminuted depending on their state of production or delivery. They shall not increase the water demand of the cement appreciably, impair the resistance of the concrete or mortar to deterioration in any way or reduce the corrosion protection of the reinforcement.

Note Information on the minor additional constituents in the cement should be ayailable from the manufacturer on request.

5.4   Calcium sulfate

Calcium sulfate is added to the other constituents of cement during its manufacture to control setting.

Calcium sulfate can be gypsum (calcium sulfate dihydrate, CaS04.2H20), hemihydrate (CaS04 ,'/2H O), or anhydrite (anhydrous calcium sulfate, CaS04) or any mixture of them. Gypsum and anhydrite are found naturally Calcium sulfate is also available as a by-product of certain industrial processes.

5.5   Additives

Additives for the purpose of EN 197-1 are constituents not covered in 5.2 to 5.4 which are added to improve the manufacture or the properties of the cement.

The total quantity of additives shall not exceed 10 % by mass of the cement (except for pigments). The quantity of organic additives on a dry basis shall not exceed 0.5 % by mass of the cement.

These additives shall not promote corrosion of the reinforcement or impair the properties of the cement or of the concrete or mortar made from the cement.

When admixtures for concrete, mortar or grouts conforming to the EN 934 series are used in cement the standard notation of the admixture shall be declared on bags or delivery documents.

6   Composition and notation

The 27 products in the family of common cements, covered by EN 197-1, and their notation are given in Table 1. They are grouped into five main cement types as follows:

-   CEM I   Portland cement

-   CEM II   Portland-composite cement

-   CEM III   Blastfurnace cement

-   CEM IV   Pozzolanic cement

-   CEM V   Composite cement

The composition of each of the 27 products in the family of common cements shall be in accordance with Table 1.

Note For clarity in definition, the requirements for the composition refer to the sum of all main and minor additional constituents. The final cement is to be understood as the main and minor additional constituents plus the necessary calcium sulfate (see 5.4) and any additives (see 5.5),

Table 1 - The 27 products in the family of common cements

     

Composition (percentage by mass ')

Main

products (types of common cements)

Main constituents

Minor

types

Clinker
K

Blast- furnace slagS

Silica fume Dh

Pozzolana natural P

natural calcined 0

Fly ash siliceousV

calcareous W

Burnt shale T

LimesL

tone LL

additional


consument

CEM I

Portland

CEM I

95-100

*

     

-

   

-

 

0-5

   

CEM n/A- s

80-94

6-20

*

--

-

-

 

*

0-5

 

slag cement

CEM il/B- S

65-79

21-35

   

-

-

   

-

 

0-5

 

Portland- •silica fume cement

CEM 11/A-O

90-94

 

6-10

   

-

     

0-5

 

Portland -

CEM H/A- p

80-94

   

6-20

 

.

*

-

-

 

0-5

 

pozzolana cement

CEM II/B- P

65-79

   

21 -35

     

-

 

0-5

   

CEM 11/A- Q

80-94

-

-

-

6-20

 

-

-

-

-

0-5

CEM II

 

CEM II/B-Q

65-79

-

 

-

21-35

-

¦

 

-

-

0-5

Portland-fly sh cement

CEM 11/A-V

80-94

*

 

-

 

6-20 -

       

0-5

 

CEM II/B- V

65-79

-

-

-

-

21-35

 

-

-

-

0-5

   

CEM II/A- W

80-94

-

-

-

-

 

6-20

-

-

*

0-5

   

CEM
tl/B-W

65-79

 

-

-

-

 

21 -35

-

-

 

0-5

 

Portland- burnt shale

CEM 11/A-r

80-94

-

-

-

-

-

6-20

-

 

0-5

   

CEM
II/BT

65-79

   

-

-

-

-

21-35

-

 

0-5

 

Portland-
limestone
cement

CEM 11/A-L

80-94

 

-

-

-

-

-

 

v20

 

0-5

 

CEM
tl/B-
1.

65-79

¦

-

-

-

¦

*

2i-3:i

 

0-5

   

CEM ' 11/A-LL

80-94

-

-

 

-

-

-

-

 

6-
20

)-5

   

CEM
II/B-
U.,

65-79

 

-

 

-

-

*

-

 

21-
35

V5

 

Portland- composite

CEM 11/A-M

80-94

i         

   

—6-20—

     

   -»

   

0-5

   

CEM
II/B-

65-79

         

-21-35   

   

   

   

0-5

CEM

Blastfurnace

CEM

35-64

36-6

~

t

-

   

-

'

*

0-5

Ill

cement

Ill/A

               

CEM
III/B

20-34

66-80

   

....

.

.

0-5

CEM IV

Pozzolanic cement*

CEM III/C

5-19

81-95

_

• . - • •

_

_

0-5

CEM IV/A

65-89

   

<< 11-35 >

   

0-5

CEM V

Composite cement*

CEM IV/B

45-64

   

<< 36-55 >

   

0-5

CEM V/A

40-64

18-30

 

<< 18-30 >

       

0-5

CEM V/B

20-38

31-50

-

<< - 31-50 >

-

-

-

-

0-5

(a)   The values inthe table refer to the sum of the main and minor additional constituents.
(b)   The proportion of silica fume is limed to 10%.
(c)   In Portland-composition cements CEM II/A-M and CEM II /B-M, in pozzolanic cements CEM IVIV/A and CEM IV B and in composite cements CEMV /A and CEM V /B the main constituents other than clinker shall be dclared by designation of the cement (for example see clause 8)

7 Mechanical, physical, chemical and durability requirements

7.1   Mechanical requirements

7.1.1   Standard strength

The standard strength of a cement is the compressive strength determined in accordance with EN 196-1 at 28 days and shall conform to the requirements in Table 2.

Three classes of standard strength are included:class 32.5, class 42.5 and class 52.5 (see Table 2).

7.1.2   Early strength

The early strength of a cement is the compressive strength determined in accordance with EN

196-1 at either 2 days or 7 days and shall conform to the requirements in Table 2.

Two classes of early strength are included for each class of standard strength, a class with ordinary early strength, included by N, and a class with high early strength, indicated by R (see Table 2).

Table 2-mechanical and physical requirement given as characteristic values

Strength class

Compressive strength MPa

Initial asettin

Soundnes s

Early strength

Standard strength

g time min

(expansion) mm

 

2 days

7 days

28 days

32.5 N

>16.0

<<32.5

<<52.5

i_75

 

32.5 R

>10.0

-

       

42.5   N
42.5   R

> 10.0 >20.0

-

>42.5

<<62.5

>60

<<10

52.5 N

>20.0

-

>52.5

-

>45

 

52.5 R

>30.0

-

       

7.2   Physical Requirements 7.2.1 Initial setting time

The initial setting time, determined in accordance with EN 196-3, shall comply with the requirements of Table 2.

7.2.2   Soundness

The expansion, determined in accordance with EN 196-3, shall comply with the requirement in Table 2.

7.3   Chemical Requirements

The properties of the cements of the cement type and strength class shown in columns 3 and 4 respectively of Table 3 shall conform to the requirements listed in column 5 of this Table when tested in accordance with the standard referred to in column 2.

Note Some European countries have additional requirements for the content of water-soluble hexavalent chromium (see Informative Annex A).

7.4   Durability requirements

In many applications, particularly in severe environmental conditions, the choice of cement has an influence on the durability of concrete, mortar and grouts, e.g. frost resistance, chemical resistance and protection of reinforcement.

The choice of cement, from EN 197-1, particularly as regards type and strength class for different applications and exposure classes shall follow the appropriate standards and/or regulations for concrete or mortar valid in the place of use.

Table 3. Chemical requirements given as characteristic values

1

2

3

4

5

Property

Test reference

Cement type

Strength class

Requirements“

Loss on ignition

EN 196-2

CEM I CEM III

all

<< 5.0%

Insoluble residue

EN 196-2 b

CEM I CEM III

all

<

Sulphate content (as S03)

EN 196-2

CEM 1 CEM 1 c CEM 11 CEM IV CEM V

32.5   N 32.5   R 42.5   N 42.5   R 52.5   N 52.5   R

<

   

CEM III d

all

 

Chloride content

EN 196-21

all'

all

<< 0.10 %r

Pozzolanicity

EN 196-5

CEM IV

all

Satisfies the test

‘ Requirements are given as percentages by mass of the final cement. b Determination of residue insoluble in hydrochloric acid and sodium carbonate. c Cement type CEM II/B-T may contain up to 4.5 % sulphate for all strength classes. d Cement type CEM III/C may contain up to 4.5 % sulfate.

'Cement type CEM III may contain more than 0.10 % chloride but in that case the maximum chloride content shall be stated on the packaging and/or the delivery note.

f For pre-stressing applications cements may be produced according to a lower requirement. If so, the value of 0.10 % shall be replaced by this lower value which shall be stated in the delivery note.

8   Standard designation

CEM cements shall be identified by at least the notation of the cement type as specified in Table 1 and the figures 32.5,42.5 or 52.5 indicating the strength class (see 7 1). In order to indicate the early strength class the letter N or the letter R shall be added as appropriate (see 7.1).

EXAMPLE 1

Portland cement conforming to EN 197-1 of strength class 42.5 with a high early strength is identified by:

Portland cement EN 197-1 - CEM 142.5 R

EXAMPLE 2

Portland-limestone cement containing between 6 % and 20 % by mass of limestone with a TOC content not exceeding 0.50 % by mass (L) of strength class 32.5 with an ordinary early strength is identified by:

Portland-limestone cement EN 197-1 - CEM II/A-L 32.5 N

EXAMPLE 3

Portland-composite cement containing in total a quantity of granulated blastfurnace slag (S), siliceous fly ash (V) and limestone (L) of between 6 % and 20 % by mass and of strength class

32.5   with a high early strength is identified by:

Portland-composite cement EN 197-1 - CEM II/A-M (S-V-L) 32.5 R

EXAMPLE 4

Composite cement containing between 18 % and 30 % by mass of granulated blastfurnace slag (S) and between 18 % and 30 % by mass of siliceous fly ash (V) of strength class 32.5 with an ordinary early strength is identified by:

Composite cement EN 197-1 - CEM VIA (S-V) 32.5 N

9   Conformity criteria

9.1   General requirements

Conformity of the 27 products to EN 197-1 shall be continually evaluated on the basis of testing of spot samples. The properties, test methods and the minimum testing frequencies for the auto-control testing by the manufacturer are specified in Table 4. Concerning testing frequencies for cement not being dispatched continuously and other details, see EN 197-2.

For certification of conformity by an approved certification body, conformity of cement with EN

197-1 shall be evaluated in accordance with EN 197-2.

Note EN 197-1 does not deal with acceptance inspection at delivery.

Table 4 - Properties, test methods and minimum testing frequencies for the auto-control testing by the manufacturer, and the statistical assessment procedure

     

Auto-control testing

Property

Cements to be tested

Test method a 1

Minimum testing frequency

Statistical assessment procedure

Routine
situation

Initial period for a new type of cemen

Inspection by Variables e

Attributes

1

2

3

4

5

6

7

Early
strength
Standard
strength

All

EN 196-1

2/week

4/week

X

 

Initial
setting
time

All

EN 196-3

2/week

4/week

 

xf

Loss on ignition

CEM I, CEM III

EN 196-2

2/monthc

1 / week

 

xf

Soundness
(Expansion)

All

EN 196-3

1 /week

4/week

 

X

Insoluble
residue

CEM I, CEM III

EN 196-2

2/month C

1 /week

 

xf

Sulphate
content

All

EN 196-2

2/week

4/week

 

xf

Chloride
content

All

EN 196-21

2/month

1/week

 

xf

V/yolunicit}

CEM IV

EN 196-5

2/month

1/week

 

x

   

5

     

Composition

All

_ d

1/month 1/week

   

a Where allowed in the relevant part of EN 196, other methods than those indicated may be used provided they give results correlated and equivalent to those obtained with the reference method. b The methods used to take and prepare samples shall be in accordance with EN 196-7. c When none of the test results within a period of 12 months exceeds 50 % of the characteristic value the frequency may be reduced to one per month. d Appropriate test method chosen by the manufacturer.
e If the data are not normally distributed then the method of assessment may be decided on a case by case basis.
f If the number of samples is at least one per week during the control period, the assessment may be made by variables.

9.2   Conformity criteria for mechanical, physical and chemical properties and evaluation procedure

9.2.1   General

Conformity of cement with the requirements for mechanical, physical and chemical properties in EN 197-1 is assumed if the conformity criteria specified in 9.2.2 and 9.2.3 are met. Conformity shall be evaluated on the basis of continual sampling using spot samples taken at the point of release and on the basis of the test results obtained on all auto-control samples taken during the control period.

9.2.2   Statistical conformity criteria 9 2 2 1 General

Conformity shall be formulated in terms of a statistical criterion based on:

-   the specified characteristic values for mechanical, physical and chemical properties as given in 7.1,7.2, and 7.3 of EN 197-1;

-   the percentile Pk, on which the specified characteristic value is based, as given in Table 5;

-   the allowable probability of acceptance CR, as given in Table 5.

Table 5 - Required values Pk and CR

 

Mechanical requirements

 
 

Early and
standard
strength

Standard
strength

Physical and
chemical
requirements

 

(Lower limit)

(Upper limit)

 

The percentage Pk on which the characteristic value is based

5%

10%

 

Allowable of probability acceptable CR

5 %

Note Conformity evaluation by a procedure based on a finite number of test results can only produce an approximate value for the proportion of results outside the specified characteristic value in a population. The larger the sample size (number of test results), the better the approximation. The selected probability of acceptance CR controls the degree of approximation by the sampling plan.

Conformity with the requirements of EN 197-1 shall be verified either by variables or by attributes, as described in 9.2.2.2 and 9.2.2.3 as specified in Table 4.

The control period shall be 12 months.

9.2.2.2   Inspection by variables

For this inspection the test results are assumed to be normally distributed.

Conformity is verified when equation(s) (1) and (2), as relevant, are satisfied:

~X - kA x s e” L   (1)

and

X+kAxsd”U   (2)

where

X's arithmetic mean of the totalityof the auto-control test results in the control period;

s   is the standard deviation of the totality of the auto-control test results in the

control period;

kA is the acceptability constant;

L   is the specified lower limit given in Table 2 referred to in 7.1;

U   is the specified upper limit given in Tables 2 and 3 referred to in clause 7.

The acceptability constant kA depends on the percentile Pk on which the characteristic value is based, on the allowable probability of acceptance CR and on the number n of the test results. Values of kA are listed in Table 6.

Table 6 - Acceptability constant kA

Number of

nk. ¦ A

test results

for Pk = 5 %

or Pk= 10%

 

(early and standard strength, lower limiit

(other properties)

20 to 21

2.40

1.93

22 to 23

2.35

1.89

24 to 25

2.31

1.85

26 to 27

2.27

1.82

28 to 29

2.24

1.80

30 to 34

2.22

1.78

35 to 39

2.17

1.73

40 to 44

2.13

1.70

45 to 49

2.09

1.67

50 to 59

2.07

1.65

60 to 69

2.02

1.61

70 to 79

1.99

1.58

80 to 89

1.97

1.56

90 to 99

1.94

1.54

100 to 149

1.93

1.53

150 to 199

1.87

1.48

200 to 299

1.84

1.45

300 to 399

1.80

1.42

>400

1.78

1.40

Note - Values given in this table are valid for CR = 5 %.

" Values of kA valid for intermediate values of n may also be used.

9.2.2.3   Inspection by attributes

The number CD of test results outside the characteristic value shall be counted and compared with an acceptable number CA, calculated from the number n of auto-control test results and the percentile Pk as specified in Table 7.

Conformity is verified when equation (3) is satisfied:

CD ^CA   (3)

The value of CA depends on the percentile Pk on which the characteristic value is based, on the allowable probability of acceptance CR and on a number n of the test results. Values of CA are listed in Table 7.

Table 7 - Values of CA

Number of test results n a

CA for Pk= 10 %

20 to 39

0

40 to 54

1

55 to 69

2

70 to 84

3

85 to 99

4

100 to 109

5

110 to 123

6

124 to 136

7

Note Values given in this table are valid for CR = 5 %.

a If the number of test results is n << 20 (for =10%) a statistically based conformity criterion is not possible. Despite this, a criterion of C„ = 0 shall be used in cases where n << 20. 7 A

9.2.3   Single result conformity criteria In addition to the statistical conformity criteria, conformity of test results to the requirements of EN 197-1 requires that it shall be verified that each test result remains within the single result limit values specified in Table 8.

Table 8 - Limit values for single results

Property Limit values for single results
Strength class
32.5N 32.5R 42.5N 42.5R 52.5N 52.5R
Early strength CMP a) 2 dav 8.0 8.0 18.0 18.0 28.0
lower limit value 7 dav - - - 14.0
Standard strength 28 day
(MPa) lower limit
vaJue
30. 030.0 40.0 40.0 50.0 50.0
Initial setting time (min) lower limit value 60 50 40
Soundness (expansion, mm) upper limit value 10
Sulfate content (as % SO,) upper limit value CEM I
CEM IIa CEM IV
CEM V
CEM III/A
CEM III/B
CEM III/C
4.0   4.5 4.5
5.0
Chloride content (%)b upper 0.10c limit value
Pozzolanicity positive at 15 davs

* Cement type CEM II/B- T may contain up to 5.0 % S03 for all strength classes.

b Cement type CEM III may contain more than 0.10 % chloride but in that case the maximum chloride content shall be declared.

‘ For pre-stressing applications cements may be produced according to a lower requirement. If so, the value of 0.10 % shall be replaced by this lower value which shall be stated in the delivery note.

9 3 Conformity criteria for cement composition

At least once per month the composition of the cement shall be checked by the manufacturer, using as a rule a spot sample taken at the point of release of the cement. The cement composition shall meet the requirements specified in Table 1. The limiting quantities of the main constituents specified in Table 1 are reference values to be met by the average composition calculated from the spot samples taken in the control period. For single results, maximum deviations of -2 at the lower and +2 at the higher reference value are allowed. Suitable procedures during production and appropriate verification methods to ensure conformity to this requirement shall be applied and documented.

9.4   Conformity criteria for properties of the cement constituents

The cement constituents shall meet the requirements specified in clause 5. Suitable procedures during production to ensure conformity with this requirement shall be applied and documented.

Annex A

(informative) A-deviation

A-deviation: national deviation due to regulations, the alteration of which is for the time being outside the competence of the CEN/CENELEC members. In the CEN member countries these A- deviations are valid in addition to the relevant requirements of EN 197-1 until they have been removed.

For EN 197-1 national A-deviations have been applied according to EC-Directive 90/531 by Denmark, Finland, Germany, Iceland, Norway and Sweden. Reference is made to the following national regulations.

Denmark:   Arbejdstilsynets bekendtgerelse nr. 661 af 28. November 1983 om

vandoploseligt chromat i cement.

Finland: Decision of the Council of State concerning the content of chromate in cement for concrete and masonry cement, No. 593, July 24, 1986.

Germany:   Gefahrstoffverordnung (GefStoffV) together with TRGS 613 “Ersatzstoffe,

Ersatzverfahren und Verwendungsbeschrankungen fur chromathaltige Zemente und chromathaltige zementhaltige Zubereitungen, April 1993 (BArbBI Nr. 4.1993)”.

Iceland: Reglur nr. 330/1989 um kr6m i sementi, Order No. 330 of 19 June 1989.

Norway: Directorate of Labour Inspection; Regulations relating to the Working Environment, laid down on 23 October 1987.

Sweden: Kamikalieinspektionens foreskrifter om kemiska produkter och biotekniska organismer, KIFS 1998:8,4 avdelning, 8 kap §§ 10-13, Kemikalieinspektionens allmanna rid till fSreskriftema om krom I cement, 1989:1.

Annex ZA

(Informative) Provisions for the CE marking of common cements under the EU Construction Products Directive

ZA.1 Clauses of EN 197-1 addressing the provisions of EU Construction Products Directive

EN 197-1 and this Annex ZA have been prepared under a mandate 2) given to CEN by the European Commission and the European Free Trade Association.

The clauses of EN 197-1, shown in Table ZA.l, meet the requirements of this Mandate given under the EU Construction Products Directive (89/106/EEC).

Compliance with these clauses confers a presumption of fitness of common cements covered by EN 197-1 for the intended use(s) under consideration in Table ZA.2.

Warning   Other requirements and other EU Directives, not affecting the fitness for

intended use(s), can be applicable to a construction product falling within the scope of EN

197-1.

There may be requirements on dangerous substances applicable to the products falling within the scope of EN 197-1 (e.g. transposed European legislation and national laws, regulations and administrative provisions). In order to meet the provisions of the EU Construction Products Directive, these requirements need also to be complied with, when and where they apply.

Note. An informative database of European and national provisions on dangerous substances is available at the Construction website on EUROPA (CREATE, accessed through http:// europa.eu.intV

2)   Ml 14 “Cement, building lies and other hydraulic binders”

Table ZA. 1 Harmonised clauses

Contruction Products: 27 different common cement products (see Table 1) Intended use(s): Preparation of concrete, mortar, groout and other mixes for construction and for the manufacture of consruction products (see notes in this Table

Requirements/performance
characteristics

Harmonis 197-1 Clauses

ed clauses ¦ in EN CPD
Article Notes
Outline of the ^ ^ level(s)
requirements and/or class(es)

Commoncements (Subfamilies) costituents and composition

3
4
5
6 8 9

Constitutions of the 27different products(Table constituents and compositionl) in the Product family“Common cements”, defined on the basis of constituent materials and composition

None

Selection of cements by the Member States in technical regulations for particular intended uses shall be possible, based on the different cement products and on strength classes.

Compressive strength (early and standard)

7.1
8
9

Compressive strength requirements expressed in terms of strength classes and limits.b

None

Setting time

7 2 9

Requirements expressed in terms of lower limits b

None

 

Insoluble residue

7.3

Requirements expressed in terms of upper limits. b

None

Only for CEM I and CEM III.

Loss on ignition

7.3
9

Requirements expressed in terms of upper limits.b

None

Only for CEM I and CEM III.

Soundness
-   Expansion


-   SO, content

7.2
9

Requirements expressed in terms of upper limits. b

None

 

Chloride content

7.3
9

Requirements expressed in terms of upper limits. b

None

 

Pozzolanicity (for pozzolanic cement only)

7.3 9

Requirements expressed in terms of limits.b

None

Only for CEM IV.

Durability

4
5
7.4

   

Durability relates to the concrete, mortar, grout and other mixes made from cement according to the application rules valid in the place of use.

“ The requirements in these clauses, including the entire contents and tables of the clauses listed, are fully integrated parts of this harmonised European Standard for cement.

b These limits are part of the definition of the products covered by this harmonised European Standard for cement.

ZA.2 Procedure for the attestation of conformity of products

The system of attestation of conformity for the 27 common cement products indicated in table ZA. 1 is shown in table ZA.2 for the indicated intended use(s), in accordance with the Commission Decision of 14 July 1997 (97/555/EC) published in the Official Journal of the European Communities and given in annex 3 of the Mandate for the product family “Cements”.

Table ZA.2 System of attestation of conformity

Product(s)

Intended use(s)

Level(s) or class(es)

Attestation


of


conformity


system(s)

Common cements, including:

Preparation of concrete, mortar, grout and other mixes for construction and for the manufacture of construction products

 

1 +

-   Portland cements


-   Portland composite cements Portland-slag cement Portland-silica fume cement Portland-pozzo lana cement Portland-fly ash cement Portland-burnt shale cement Portland-limestone cement Portland composite cement


-   Blastfurnace cements


-   Pozzolanic cements


-   Composite cements


-   Composite cements

System 1 +: See annex III Section 2 point (i) of Directive 89/106/EEC, with audit-testing of samples taken at the factory

The attestation of conformity to the specifications in EN 197-1 shall be based on clause 9 ofEN

197-1 and on evaluation of conformity3) which shall be in accordance with EN 197-2. Clause 8 of EN 197-2 does not apply since it is superseded for CE marking purposes by the rules given in clauses ZA.3 and

ZA.4. Clause 9 of EN 197-2, giving rules relating to Dispatching Centres, is not part of the procedure of attestation of conformity for the affixing of the CE marking under the CPO. However, Member States, within their market surveillance obligations, must ensure that CE marking is correctly used (Article 15.1 oftheCPO). Clause9ofEN 197-2 should be used for the corresponding national provisions concerning Dispatching Centres.

3)   This term corresponds to the establishment of conformity that is mentioned in article 13.2 of the CPO

ZA.3 EC certificate of conformity and EC declaration of conformity

When compliance with the system of attestation of conformity is achieved in accordance with clause 7 of EN 197-2, the certification body shall draw up a certificate of conformity (EC certificate of conformity) with the information indicated below. This EC certificate of conformity entitles the manufacturer to affix the CE marking, as described in ZA.4.

The EC certificate of conformity shall include the following information:

-   Name and address of the certification body,

-   Name and address of the manufacturer, or his authorised representative established in the EEA, and place of production,

-   Description of the product (the standard designation of the cement according to EN

197-1 and any additional identification required),

-   Provisions to which the product conforms (annex ZA of EN 197-1, with conformity established according to EN 197-2 as given in annex ZA of EN 197-1),

-   Particular conditions applicable to the use of the product (none as regards conformity),

-   The certificate’s number,

-   Conditions and period of validity of the certificate, where applicable,

-   Name of, and position held by, the person empowered to sign the certificate.

In addition, for each product covered by an EC certificate of conformity, the manufacturer shall draw up a declaration of conformity (EC declaration of conformity) including the following information:

-   Name and address of the manufacturer, or his authorised representative established in the EEA,

-   Number of the attached EC certificate of conformity,

-   Name of, and position held by, the person empowered to sign the declaration on behalf of the manufacturer or of his authorised representative.

Both documents must be presentèd in the official language or languages of the Member State of the EU in which the product is to be used.

ZA.4 CE conformity marking Z A. 4.1 Bagged cement

In the case of bagged cement, the CE conformity marking, the identification number of the certification body and the accompanying information as given below should be affixed either on the bag or on the accompanying commercial documents or on a combination of these. If all the information is not placed on the bag, but only part, then the full information should be given on the accompanying commercial documents.

For reasons of practicality, selections from the following alternative arrangements for bagged cement concerning the presentation of the accompanying information may be used:

¦HM

CE conformity marking, consisting of the “CE”- symbol given in Directive 93/68/EEC

0123

Identification number of the certification body Name or identifying mark of the producer

Any Company

Registered address of the producer

The registered address

Name or identifying mark of the factory where

Any Factory4)

the cement was produced 4)

Year 01


(or position of date stamping)

The last two digits of the year in which the marking was affixed5)


Number of the EC certificate of conformity

0123-CPD-0456

Number of European standard

EN 197-1 CEM 142,5R

Example of standard designation, indicating the cement product and the strength class, as specified in clause 8 ofEN 197-1

 

Limit for chloride, in %6)

 

Limit for loss on ignition of fly ash, in %71

Additional information

Standard notation of admixture8)

4)   Considered necessary for the requirements of EN 197-2 but not compulsory.

51 The year 6f marking should relate to either the time of packing into bags or the time of dispatch from the factory or depot.

6)   Only where the common cement is produced to meet a different chloride content limit to the value specified in Table 3 of EN 197-1.

7)   Only where, in accordance with 5.2.4.1 of EN 197-1, a fly ash loss on ignition limit of 5.0% to 7.0% is used.

8)   Only where, in accordance with 5.5 ofEN 197-1, an admixture conforming to the EN 934 series is used.

(a)   When the CE marking is given on the bag (this is the normal situation and is preferred) the following elements of the accompanying information may be given on the accompanying commercial documents instead of on the bag:

-   the name or identifying mark of the factory;

-   the year of affixing the CE marking;

-   the number of the EC certificate of conformity;

-   additional information.

   (b)   Where the last two digits of the year in which the CE marking is affixed is pre- printed on the bag, the year so printed should relate to the date of affixing with an accuracy of within plus or minus three months.

   (c)   Where the last two digits of the year in which the marking is affixed is to be presented but not pre-printed on the bag it may be applied by means of date-stamping of the bag in any easily visible position. This position should be indicated in the information accompanying the CE marking.

The product should be accompanied, when and where required and in the appropriate form, by documentation listing any legislation on dangerous substances for which compliance is claimed, together with any information required by that legislation. Note: European legislation without national derogations need not be mentioned.

ZA.4.2 Bulk cement

In the case of bulk cement, the CE conformity marking, the identification number of the certification body and the accompanying information as listed for babagged cement in ZA. 4.1 should be affixed in some suitable practical form on the accompanying commercial documents.

 

SECOND SCHEDULE

[Paragraph 3]

1.

ZS 369

Automotive gas oil (diesel fuel)

2.

ZS 380

Illuminating kerosene

3.

ZS 395

Unleaded petrol (Gasoil) for motor vehicles

4.

ZSEN197

Cement: composition, specifications and conformity criteria for

   

common cements

 

STANDARDS (IMPORTS) (QUALITY MONITORING) REGULATIONS, 2003

[Sections 7 and 37]

Arrangements of Regulations

Regulation

   1. Title

   2. Interpretation

   3. Application for import commodity clearance

   4. Consignment to be evaluated

   5. Conditional release of consignment

   6. Issuance of import commodity clearance

   7. Withdrawal of import quality certificate

   8. Disposal of sample

   9. Fees

   10. Warranty

   11. Penalties

      FIRST SCHEDULE

      SECOND SCHEDULE

      THIRD SCHEDULE

      FOURTH SCHEDULE

      FIFTH SCHEDULE

SI 41 of 2003,

SI 78 of 2003.

 

1. Title

These Regulations may be cited as Standards (Imports) (Quality Monitoring) Regulations, 2003.

 

2. Interpretation

In these Regulations, unless the context otherwise requires–

“Authority” means the Zambia Revenue Authority established under the Zambia Revenue Authority Act;

“Bureau” means the Zambia Bureau of Standards;

“consignment” means a batch of products bearing a brand name from the same manufacturer and same country of origin;

“foreign or international standard” means a standard developed by a foreign standards body or the International Organisation for Standardisation (ISO), International Electrotechnical Commission (IEC), Codex Alimentarius Commission or other international body which may be recognised by the Bureau for purposes of the Bureau Product Certification Mark Scheme;

“import certificate of conformance” means a document issued by the Bureau upon being satisfied of the evaluation of a consignment;

“import commodity clearance"  means the clearance granted under regulation 7 in respect of imported commodities;

“import entry packing list” means a documented inventory of commodities in a consignment that is imported;

“importer” means an individual, firm, or organisation involved in the direct procurement of commodities from outside the boundaries of the Republic of Zambia, for the purposes of selling, distributing or processing or any other use;

“import quality certificate” means a document issued annually by the Bureau to an importer of a commodity of the same brand from the same manufacturer and the same country of origin after four consecutive import shipments have been evaluated and found to conform to the relevant standards determined under the Act; and

“test certificate” means a document, issued by a laboratory, indicating the test results of a product.

 

3. Application for import commodity clearance

   (1) An importer of a consignment containing a designated product listed in the First Schedule and to which standards declared under the Act apply shall apply to the Bureau for import commodity clearance before arrival of the consignment at a port of entry and prior to the Authority’s release of the consignment.

   (2) An application for import commodity clearance shall be made by way of an Import Inspection Request Form, IQM 01, as set out in the Second Schedule.

   (3) The Form shall be submitted to the Bureau triplicate together with an import entry packing list, the original copy of any test certificate, including the results if any, and any other shipping documents.

   (4) The consignment referred to in sub-regulation (1) shall be subject to sampling and testing by an inspector.

 

4. Consignment to be evaluated

   (1) A consignment that is imported shall be evaluated by an inspector to determine its conformity to the applicable standards declared under the Act.

   (2) An inspector, shall subject to sub-regulation (3) take samples for the purposes of laboratory analysis and shall complete, and issue to the person from whom a sample is taken, Sample Request Form, IQM 02, as set out in the Third Schedule.

   (3) The sampling and testing of a consignment that is imported into Zambia may be waived where–

   (a)   the consignment is certified by a reputable competent testing organisation in the country of origin and duly recognised by the Bureau or relevant government authorities as conforming with the applicable standards under the Act; and

   (b)   the first four consecutive imported consignments, notwithstanding the certification that they conform to standards declared under the Act, are sampled and tested by the Bureau and the technical findings are found consistent with foreign test certificates issued after the commodities are found to conform to a foreign or international standards, and the applicable standards declared under the Act.

   (4) where random checks, which may include sampling and testing, reveal inconsistencies between the actual quality of imported products and the foreign test certificates issued stating that the products conform to the standards declared under the Act, a subsequent import of a consignment from the country concerned shall subject to sampling and testing by the Bureau, notwithstanding any certification from the country of origin, that the consignment conforms to the standards declared under the Act.

 

5. Conditional release of consignment

   (1) Where the testing of any sample taken under sub regulations (2) of regulation 4 takes more than 20 days, an inspector may, upon the importer satisfying the Bureaus conditions for such release, conditionally release the consignment from the Authority’s custody.

   (2) An inspector shall seal an imported consignment–

   (a)   prior to releasing the consignment under sub regulation (1); or

   (b)   where the consignment is to be transferred from the authority’s custody to the warehouse of the importer or consignee where an evaluation is to be performed.

   (3) An importer or any other person shall not sell or transfer a consignment released under this regulation, whether in whole or as a part of its unless an importer commodity clearance is issued in respect of that consignment.

 

6. Issuance of import commodity clearance

   (1) The Director or any other person authorised by the Director so to do shall issue import commodity clearance on a consignment where satisfied that the imported consignment conforms to the standards declared under the Act.

   (2) Certificates shall be issued for import commodity clearance in the following two categories:

   (a)   a batch import certificate of conformance, as set out in the Fourth Schedule; or

   (b)   an import quality certificate, as set out in the Fifth Schedule.

   (3) The validity of batch import certificate of conformance shall lapse upon the expiration of the shelf-life of the product to which it relates.

   (4) A certificate may be re-issued in respect of a consignment subject to the consignment being re-evaluated.

 

7. Withdrawal of import quality certificate

   (1) The Bureau shall withdraw an import quality certificate issued under paragraph (b) of sub regulation (2) of regulation 6 from an importer on the following grounds:

   (a)   if upon random sampling, on the open market of a product covered by the certificate and imported by the holder of a certificate the product is found to be non conforming to the standards declared under the Act;

   (b)   If the importer contravenes any provision of the Act; or

   (c)   If the importer fails to pay any fee as required by these Regulations:

Provided that prior to withdrawing the certificate the Bureau shall give the importer concerned notice of the intention to withdraw the certificate and shall afford the importer, in such period the Bureau shall specify in the notice, an opportunity to show cause why the certificate should not be withdrawn.

   (2) The Bureau shall upon withdrawing an import quality certificate under sub regulation (1)–

   (a)   order the withdrawal of the imported product from the market;

   (b)   inform the public, by such means as it may determine, of the dangers of using or consuming the particular non-conforming product; and

   (c)   direct the importer to dispose of any recoverable non-conforming imported product.

   (3) The expenses incurred by the Bureau in undertaking all the activities under sub-regulation (2) shall be borne by the importer of the non-conforming product.

   (4) A person who sells an imported product shall ensure that the imported product is duly certified, by the Bureau, as conforming to the standards declared under the Act.

   (5) A person who sells an imported product to which these Regulations apply shall, when required to do so by Bureau or an inspector disclose the name of the supplier of the product.

   (6) If a person when required to do so by the Bureau or an inspector refuses to disclose the name of the supplier of an imported product referred to in regulation (5), the Bureau shall conduct an evaluation on the product or consignment in accordance with the procedures laid down in these Regulations and that person shall bear the costs incurred during such evaluation.

 

8. Disposal of sample

   (1) The Bureau shall, wherever possible, return to the importer all samples drawn from a consignment for testing and laboratory analysis including those that have undergone destructive testing.

   (2) The importer shall withdraw the samples from the Bureau within 30 days after receipt of notice to recover the samples.

   (3) Where the importer fails to withdraw the samples after the specified date, the Bureau may dispose off the samples as it considers appropriate.

 

9. Fees

   (1) An importer shall, prior to a consignment being cleared by the authority, pay to Bureau the following:

   (a)   expenses incurred by an inspector for the purpose of attending at the place and carrying out the inspection and returning from the inspection;

   (b)   testing fees charged by the Bureau or any laboratories designated by the Bureau for the testing of the imported products; and

   (c)   the fees charged for the issuance of a report and the batch import conformance certificate.

 

10. Warranty

Every person who imports, displays, distributes or sells any product which is subject to standards declared under the act is deemed to warrant to the immediate purchaser that the product conforms to all requirements under the Act.

 

11. Penalties

A person who contravenes these Regulations commits an offence and shall be subject to legal proceedings under the Act.

 

FIRST SCHEDULE

[Regulations 3]

[First sch am by reg 2 of SI 78 of 2003.]

DESIGNATED PRODUCTS SUBJECT TO IMPORT QUALITY MONITORING

Name of product

Asbestos-cement pressure pipe

Asbestos roofing sheet;

Beer

Biscuits

Bottled Water;

Canned pineapples

Cattle feeds

Cement

Compound fertilizers

Crude vegetable oil;

Hair creams

Hair oils

Household and dishwashing liquid detergent

Household electrical appliances

Incandescent lamps;

Jams, jellies and marmalades

Laundry soaps

Lead-acid starter batteries

Margarine;

Paint;

Petroleum jelly;

Pneumatictyres;

Poultry feeds

Primary dry batteries;

Pure glycerine;

Refined edible vegetable oil

Rubber condoms (single use)

Safety belt and harnesses

Safety footwear

Shoe polish

Toilet soap

Varnishes;

Wheat flour

 

SECOND SCHEDULE

[Regulation 3]

FORM I QM 01

ZAMBIA BUREAU OF STANDARDS

The Standard (Imports) (Quality Monitoring) Regulations

IMPORT INSPECTION REQUEST FORM

(Please complete 1 to 8 of this form and fax/forward to the Zambia Bureau of Standards. Please not that incomplete information may cause delays in processing your application).

1. Importer (Name and Address) Tel: Fax

2. Supplier (Name and Address)Tel: Fax

3. Forwarding AgentTel: Fax Container No.(s): Serial No:

4. Product brand

 
 

5. No. and Kind of package:

 
 

6. Quantity

 

7. Importer’s specifications:

 

8. TO THE DIRECTOR, ZAMBIA BUREAU OF STANDARDS Please Kindly inspect the import consignment described above and issue an import certificate of conformance/import quality certificate.The consignment can be inspected at ...................... which is ................. km from Lusaka.I undertake to settle all fees chargeable and abide by the Declaration Order governing the Import Quality Monitoring Scheme (IQMS)............................................ Name of Importer/Representative ........................................... signature of importer/Representative

9. FOR OFFICIAL USE ONLY(PARAMETERS AND IQMS FEES)

Parameter(s)

Application standards under the Act

Item

Rate

Amount (ZMK)

* Registration

   

* Inspection & sampling

   

* Testing

   

* Transporting

   

* Reporting

   

* Certification

   

* Subsistence allowance

   
 

TOTAL

 

........................................... Signature of ZABS Officer* As stipulated in the ZABS Product Certification MarkScheme Date ......................................

 

THIRD SCHEDULE

[Regulation 4(2)]

ZAMBIA BUREAU OF STANDARDS

FORM I QM 02

The Standards (Import) (Quality Monitoring) Regulations

SAMPLE REQUEST FORMS

Name of Importer or Agent ........................................................... Address:........................

............................................................ Phone:............................... Fax ................................

Name or Description of Product(s):

................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................

Identification marks:................................................................................................................................................

..................................................................................................................................................................................................................................................................................................................................................................

Title and number of standard specification (s) applicable to the products (s)

............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................

Consignment(s) size:.................................................................................................................................................

.......................................................................................................................................................................................................................................................................................................................................................................

Sample(s) size:..........................................................................................................................................................

..................................................................................................................................................................................................................................................................................................................................................................

Identification marks on sample:.........................................................................

..................................................................................................................................................................................................................................................................................................................................................................

Name of ZABS Inspector:...................................................................................

Designation ........................................................................................................

Date:...................................................................................................................

 

FOURTH SCHEDULE

[Regulation 7(2)(a)]

FORM I QM 03

ZAMBIA BUREAU OF STANDARDS

The Standards (Imports) (Quality Monitoring) Regulations

BARCH IMPORT CERTIFICATE OF CONFORMANCE

Consignee (Name and address)

Certificate No: Reference No:

Date of issue:

Country of origin:

Consignor (name and address)

Agent (name and address)

Mode of transport :

Sea ......

Rail ......

Road .......

Air .....

Port of entry

Place of customs clearing:

Final destination:

Product brand name and description:Batch identification:

Parameter

Specification

Results

     

CERTIFICATION AND CONDITIONS OF ISSUE

THIS IS TO CERTIFY that the above mentioned brand of product bearing the indicated batch identification has been found to conform to the standards declared under the Act. This certificate only applies to the consignment or batch from which the sample was obtained and tested. Issued under the law and procedures governing the Import Quality Monitoring Scheme of the Zambia Bureau of Standards.

Seal of issuing authority: Name:...........................................

Signature ......................................

Designation ...................................

Date .............................................

 

FIFTH SCHEDULE

[Paragraph 7(2) (b)]

The Standard (Imports) (Quality Monitoring ) Regulations

IMPORT QUALITY CERTIFICATE

This is issued to:...............................................of .................................................

For the product(s) set out in the Table below in which to conform the standards applicable under the Act.

This certificate is valid for the product(s) and validity dates stated (or up to and including the dates of expiry (if applicable).

ARTICLE DESCRIPTION

Name of product(s)

Expiry date (if applicable)

Standard(s) applicable under the Act

Quantity

Port of entry

Origin

Certificate validity date

             

CERTIFICATE AND CONDITIONS OF ISSUE:

THIS IS TO CERTIFY that the above mentioned product (s) bearing the brand name .................................... has/have been found to conform to the standards applicable under the Act. This certificate only applies to the consignment (s) of the brand name from which the sample was obtained and tested. Issued under the laws and procedures governing the Import Quality Monitoring Scheme of the Zambia Bureau of Standards:

Seal of issuing authority

Name:...............................................
Signature ..........................................
Designation .......................................
Date ..................................................

 

STANDARDS (COMPULSORY STANDARDS)(DECLARATION) ORDER, 2003

[Sections 7 and 37]

Arrangements of Paragraphs

Paragraph

   1. Title

   2. Declaration of compulsory standards

   3. Application

      FIRST SCHEDULE

      SECOND SCHEDULE

SI 43 of 2003.

 

1. Title

This Order may be cited as the Standards (Compulsory Standards)(Declaration) Order, 2003.

 

2. Declaration of compulsory standards

The standards set out in the First Schedule to this Order are hereby declared as compulsory standards.

 

3. Application

The standards declared under paragraph 2 apply to the respective commodities listed in the Second Schedule.

 

FIRST SCHEDULE

[Paragraph 2]

ZAMBIA BUREAU OF STANDARDS

ZS430: 2003

BEER-SPECIFICATION

1.    SCOPE

This Standard prescribes the requirements for beer.

2.    PRODUCT DEFINITION

For the purpose of this Standard, the following definition of beer shall apply.

   2.1      Beer shall be the product of alcoholic fermentation of a mash in potable water of malted barley and hops or hops’ concentrates with or without the addition of other malted or unmated cereals or other carbohydrates preparations. Hops substitutes, bitter principles and saponins from any source shall not be used.

   2.2      Beer

      An alcoholic beverage containing 1.7 percent ethyl alcohol by volume.

3.    REQUIREMENTS

   3.1      Contaminants

      The limits of contaminants in the beer shall be those prescribed by law from time to time.

   3.2      Colorants

      Beer shall be free from any artificial colour except caramel product from sugar.

   3.3      Preservatives

      Beer may contain preservatives permitted by law. The limits shall be those prescribed by law.

   3.4      Pasteurization

      When effectively pasteurised, beer shall be free from coliform bacteria and other pathogenic micro-organisms.

   3.5      Organoleptic

      Beer shall be clear and have characteristics of colour, taste bouquet and foam of its type.

   3.6      Requirements of beer

      Beer shall also comply with the requirements set out in the Table set out below.

Characteristic

Requirements<FT:Calibri,SN>

(a) Ethyl alcohol content at ambient temperature per cent v/v, min

1,7

(b) pH, min

2,4

(c) Head retention, see, min

8,0

(d) Carbon dioxide

0,45-0,52

(e) Carbon dioxide

2,35-2,65

(f) Air in headspace, ml/Units, max

2,0

(g) Sulphur dioxide, mg/kg, max

1,5

(h) Iron, mg/kg, max

0,20

(i) Copper, mg/kg, max

0,10

(j) Lead, mg/kg, max

0,10

(k) Cadmium, mg/kg max

0,001

4.    HYGIENE

The product covered by the provision of this standard shall be prepared in accordance with the appropriate sections of ZS 034-General Principles of Food Hygiene Code of Practice and as required by the Public Health Act of the Laws of Zambia.

5.    PACKING

   5.1      General

The product shall be packed in clean and sound containers and the container shall be hermitically sealed after packing. Closures shall be clean at the time of capping or seaming.

      5.1.1.    Washing

Bottles shall be cleaned by a suitable automatic process immediately before being filled. The process shall include a pre-soak or pre-rinse; soaking or jetting with an efficient cleaning solution for a sufficient time at a high enough temperature to ensure thorough cleaning; and thorough rinsing with potable water to remove all traces of the cleaning solution from the bottles. The rinsed bottles shall not give an alkaline reaction when tested with an alcoholic solution of phenolphthalein.

   5.2      Inspection

The interior and neck finish of bottles shall be free from chips, cracks and other defects.

Bottles shall be inspected both before and after filling and defective bottles and products shall be rejected.

   5.3      Cans

Cans shall be free from dents, corrosion and serious internal scratches or other lacquer imperfections.

   5.4      Filling and sealing

Containers shall be filed under strictly hygienic conditions by means of automatic equipment maintained in a hygienic state. The open ends of containers shall not be touched by hand. Immediately after filling, the containers shall be hermetically sealed. Sealing machines shall be kept clean and contamination of the product from soiled equipment or detached, particles of material shall be avoided.

6. LABELLING

   6.1      In addition to the provision of ZS 033-Labelling of repacked foods, the following specific provisions shall be declared on each container or on its label or seal:

   (a)   the full name and address of the manufacturer;

   (b)   the name of the product;

   (c)   brand name, if any;

   (d)   batch or code number;

   (e)   range of alcohol content;

   (f)   contents in ml; and

   (g)   “best before” followed by the date.

   6.2      The container may also be marked with the ZS mark upon application by the manufacturer and approval by the Zambia Bureau of Standards.

7.    SAMPLING AND ANALYSIS

   7.1      The Methods of sampling analysis shall be in accordance with DZS* Alcoholic beverages-methods of sampling and analysis.

ZAMBIA BUREAU OF STANDARD

ZAMBIAN STANDARD

ZS438: 2003

BISCUITS – Specification

1.    SCOPE

This Zambian Standard prescribes the essential requirements and methods of sampling and tests for biscuits baked from dough made from essential materials specified under clause 2 and with or without the addition of other ingredients specified in clause 3.

2.    ESSENTIAL MATERIALS

The following material shall be used in the preparation of biscuits dough.

   2.1      Wheat flour. Complying with the requirements of ZS 435: for wheat flour.

   2.2      Fat or shortening. Hydrogenated edible vegetable oil, bakery shortenings, refined edible oils, butter oil (ghee) or margarine.

   2.3      Water: potable water for human consumption and for food processing industry.

   2.4      Edible common salt conforming to requirements of ZS 341: Zambia Standard Specification for Edible Salt.

3. OPTIONAL INGREDIENTS

In addition to the essential ingredients specified under clause 2, any of the following ingredients may be used.

   3.1. Cereal and cereal products

      Whole Wheat Meal

      Semolina

      Edible Starches

      Malt Flour

   3.2. Oil seed and oil seed products

      Soya bean

      Groundnuts (peanuts)

      Peanut butter

      Edible ground flour

   3.3      milk and milk products

      Milk (liquid or powder)

      Buttermilk

      Cheese

   3.4      Sweeteners

      Sugar (sucrose)

      Liquid glucose

      Dextrose monohydrate

      Jaggery

      Molasses (edible) cane

      Lactose

      Malt extract

      Invert syrup

      Honey

   3.5      Fruit and fruit products

      Copra

      Dry fruits

      Edible nuts

      Pectin

      Jam

   3. 6   Spices

      Ginger

      Chilli powder

      Black powder

      Cardamon

      Cumin

      Other spices permitted by the Zambia Bureau of Standards

   3.7      Miscellaneous

      Coffee powder

      Cocoa powder

      Covering chocolate

      Edible vegetables

   3.8      Enzymes and gluten conditioners. Proteolytic and amylases, sodium bisulphate and sodium metabisulphit or sulphur dioxide.

   3.9      Food additives

      3.9.1   Flavour: Flavouring essences, improvers and fixers.

      3.9.2   Colouring matter: Only permitted colours according to Zambia Bureau of Standards and meeting the relevant Zambia Standards.

      3.9.3   Antioxidants – Tartaric acid and citric acid.

      3.9.4   Emulsifying Agents – Such as lecithin and glycerol monostreerata

   3.10   Leaving agents

      Baking powder

      Ammonium bicarbonate

      Sodium bicarbonate

      Ammonium carbonate

      Active bakeries yeast

   (Seccaaromyces cerevities any other approved aerating agent).

4. REQUIREMENTS

   4.1      General requirements. The biscuits shall be properly baked with no signs of under-baking or over-baking so that they are crispy and have uniform texture and appearance. The design, if any, on the biscuits should be clear. They shall have an agreeable flavour typical of well-baked biscuits of different types and shall be free from any soapy or bitter after-taste, rancid taste and odour. The biscuits shall be free from microbial contamination, moulds and insert infestation.

NOTE:

The appearance, taste, odour, and rancid flavour shall be determined by orsanoleptic tests.

   4.2      Types of biscuits

      4.2.1   Filled biscuits, shall be biscuits sandwiched with a filling of either cream, jam, jelly, marshmallow, caramel figs raising, or the like.

NOTE:

For the purpose of this standard, ‘Cream means basically a homogenous mixed preparations of hydrosenated fat of bakery shortening. Icing sugar, flavours and permitted food colours (See 3.10.2) with or without other ingredients in small proportions.

      4.2.2   Coated biscuits. Shall be biscuits as such or with the filing in between, but coated with chocolate, caramel or icing sugar.

   4.3      Biscuits shall be manufactured, stored and handled under hygienic conditions in accordance with ZC 034. Code of hygienic conditions for food and food processing units.

   4.4      Biscuits shall also comply with the requirements set out in Table 1.

Table 1: Requirement for biscuits

Characteristic per cent by mass max

Requirements

Method for Test (Ref. To App.)<FT:Calibri,SN>

Moisture

6.0

B

Acid insoluble ash (on dry basis)

0.05

C

Acidity of extracted fat (as Oleic acid)

1.0

D

5.    PACKAGING AND MARKING

   5.1      Packaging. Biscuits shall be packed in clean, sound containers, made of tinplate, PVC sheets, cellophane paper, cardboard paper or other suitable materials in such a way as to protect them from breakage, contamination, absorption of moisture and seepage of fat from the biscuits into packing materials.

   5.2      Biscuits shall not come in direct contact with the packing materials other than greaseproof or sulphite paper, cellulose film, or any other non toxic packaging material which may be covered with a moisture proof film, waxed paper or moisture-proof laminates or coated paper.

   5.3      Making. In addition to the requirement of Zambian Standard on labelling of prepacked foods, ZS 033: the following particulars shall be clearly and indelibly marked on the label on each container:

      5.3.1   Name of the product

      5.3.2   Name and address of manufacturer

      5.3.3   Batch or code number

      5.3.4   Net weight in grams (g) or kilogramme (kg)

6.    SAMPLING

The method of drawing representative samples of the biscuits and the criteria for conformity shall be as prescribed in Appendix A.

APPENDIX A

Sampling biscuits

A1. General requirements of Sampling

   A1.1   In drawing, preparing storing and handling samples, the following precautions and directions shall be observed.

   A1.2   Samples shall be taken in a protected place not exposed to damp air, dust or root.

   A1.3   Precautions shall be taken to protect the samples, the lots being sampled, the sampling instrument and the containers for samples from adventitious contamination.

   A1.4   Loose biscuit samples, or the representative small packs shall be placed in air tight, clean and dry gloss, tin or aluminium containers of appropriate size.

   A1.5   The samples shall be stored at room temperature.

   A1.6   Such container containing the samples shall be sealed air tight and marked with full details of sampling such as date and time of sampling, batch or code number, name of the manufacturer, and other relevant particulars.

A2. Scale of sampling

   A2.1   Lot. All the biscuit containers in single consignment drawn from the same batch of manufacture shall constitute a lot. If the consignment is declared to consist of different batches or manufacture, it shall constitute lots.

      A2.1.1   Samples shall be tested for ascertaining the conformity of the biscuits to the requirements of the specification.

   A2.2   The number of containers to be sampled from each lot shall depend on the size of the lot and be in accordance with Table 2.

   A2.3   The containers to be selected at random from each lot and for this purpose, random number tables shall be used. In case such tables are not available, the following procedure shall be adopted.

Starting from any container, count them as 1, 2, 3 up to R and so on in order, where is equal to the integral part of the value N/n, being the total number of containers in the lot and the number of containers to be selected (see Table 2). Every container thus counted shall be separated until the required number of containers is obtained from the lot.

Table 2 ZS 438: 2003

Lot Size N

Sample Size N

UP to 50

2

51 to 150

3

151 to 300

4

301 to 500

4

501 to and above

5

A3. Test samples and reference samples

   A3.1   Draw from each selected container the required number of biscuit packs. These packs shall be opened and mixed. If the container is packed with loose biscuits, samples of the required quantity shall be taken from different parts of the selected container.

   A3.2   Preparation of individual sample – From the selected containers about 600g of biscuits shall be taken from the different packs of the container. From this about 300g of the biscuits shall be taken for testing the general requirements. This 300g of biscuits shall be divided into 3 equal parts, of the purchaser, another for the vendor and the third for the reference. These biscuits shall be packed in air-tight, dry containers and labelled with particulars as given in A1.5.

   A3.3   Preparation of composite sample

      A3.3.1The composit sample shall be prepared from the remaining 300g of biscuits from each selected container, after the sample for general requirements is taken out as given in A3.3.1.1 to A3.3.1.3.

         A3.3.1.1   Plain biscuits. Grind the samples as quickly as possible.

         A3.3.1.2   Filled biscuits. The cream, caramel, chocolate, marshmallow, jam, jelly or any other filling between biscuits should be removed by gently scraping, before powdering the sample.

         A3.3.1.3   Coated and Filled Biscuits. As far as possible, the coating and the fillings should be removed before powdering the biscuits.

NOTE:

The biscuits are highly hygroscopic and take up moisture quickly when exposed to the atmosphere. The preparation of sample should be done very quickly, preferably in a dry place.

      A3.3.2   A small but approximately equal quality of the material (see A3.3.1) shall be taken from the powdered sample of each selected container and mixed thoroughly so as to form a composite sample weighing not less than 200g. This sample shall be divided approximately into three equal parts, one for the purchaser, another for the vender and the third for reference. These parts shall be transferred immediately to clean, air-tight and dry containers which are then sealed air tight labelled with particulars as given in A1.5

      A3.3.3   The remaining portions of the powdered sample from each selected container (after a small quantity needed for the formation of the composite sample has been taken out) shall be divided approximately into three equal parts. These parts shall be transferred to clean, dry containers and treated the particulars given in A1.5 the sample in each such sealed container shall constitute an individual test sample. These individual samples shall be separated into three identical sets or test samples in such a way that each set has a sample representing each selected container (see Table 2). One of these sets shall be marked for the purchaser, another for the vendor and the third for the referee.

   A3.4   Referee Sample. Referee samples shall consist of a set of individual biscuit samples (A3.2 marked for general requirements, a composit sample (see A3.2) marked for general requirements, a composite sample (see A3.3.2) and a set of individual test samples (see A3.3.3.3) and shall bear the seals of the purchaser and the vendor. These shall be kept at a place agreed to between the two.

A4      Number of tests

   A4.1   The biscuits selected according to A3.2 shall be tested for general requirements.

   A4.2   Test for moisture shall be conducted individually on each of the samples constituting a set of individual test samples (see A3.3.3).

   A4.3   Tests for the determination of acid insoluble ash and acidity of extracted fat shall be conducted on the composite sample (see A3.3.2)

A5. Criteria for conformity

   A5.1   A lot shall be declared as conforming to the requirements of the specification for biscuits when the criteria given in A5.1.1 to A5.1.3 are satisfied.

      A5.1.1   In case of general requirements, the biscuits shall satisfy the requirements as given in 4.1.

      A5.1.2   For acid insoluble ash and acidity of extracted fat, the test results obtained from the composite sample (see A4.3) shall be less than or equal to 0.05 percent and 1.0 percent respectively (see Table 1)

APPENDIX B

DETERMINATION OF MOISTURE

B1. APPARATUS

      B1.1. Moisture dish - Made of porcelain, slice, glass or aluminium

      B1.2 Oven - Electric maintained at 105 ± 1°C

      B1.3 Desiccators

B2. PROCEDURE

   B2.1   Weigh accurately about 5g of the prepared sample (see A3.3.3) in the moisture dish previously dried in the oven and weighed. Place the dish in the oven maintained at 105 ± 1°C for 4 hours. Cool in the Desiccator and weigh. Repeat the process of drying, cooling and weighing at 30-minute intervals until the difference between the two consecutive weighing is less than one milligramme. Record the lowest mass.

B3. CALCULATION

   B3.1   Moisture, percent by mass = 100(m1-m2)/31 - m

Where

m1 = mass in g of the dish with the material before drying.

m2 = mass in g of the dish with material after drying to constant weight, and

m = mass in g of the empty dish.

APPENDIX C

DETERMINATION OF ACID INSOLUBLE ASH

C1. Apparatus

C1.1 Muffle Furnace

Maintained at 600° ± 20°C

C1.2 Water –bath

C1.3 Desiccator

C2. REAGENT

C2.1 Dilute Hydrochloride Acid. Approximately SN, prepared from concentrated hydrochloric acid.

C3. PROCEDURE

C3.1 Weigh accurately about 20g of the biscuit powder (A3.3.2) in the previously weighed dish and ash in the muffle furnace at 600° ± 20°C until grey ash is obtained. Remove the dish from the furnace and allow it to cool at room temperature. Add 25 ml of the hydrochloric acid to the dish, cover with a watch glass and heat on a boiling water bath for 10 minutes. Mix the contents with tip of a glass rod and filter through What man filter paper No. 42 or its equivalent. Wash the filter paper with water until the washings are free from acid tasted with a blue litmus paper. Return the washed filter paper to the dish for ashing in the muffle furnace as above. Cool the dish in the desiccators and weigh. Again ignite the dish for half an hour in the furnace, cool and weigh. Repeat this operation until the dish has the constant mass. The difference between successive weighing being less than 1 mg. Filter paper, wash, ash and weigh it as in the case of acid insoluble ash. Substitute its mass from the mass of insoluble ash of the sample.

C4. CALCULATION

C4.1 Acid insoluble ash percent by mass (A) = 100 (cm 1 – m)/ m2

Where

m1 = mass in g of the dish containing acid insoluble ash (see Note)

m = mass in g of empty dish in which the sample is taken for ashing, and

m2 = mass in g of the sample

NOTE:

Collect the acid insoluble ash mass for the blank of filter paper, if any.

C4.2 Acid in insoluble ash, per cent by mass (dry basis) = A x 100/100-m

Where

A = acid insoluble ash, per cent by mass (C4.1), and

m = percentage of moisture in the biscuits (A3.1).

APPENDIX D

DETERMINATION OF ACIDITY OF EXTRACTED FAT

D1. APPARATUS

D1.1 Soxhlet apparatus. With a 250ml of flat bottom flask.

D2. REAGENTS

D2.1. Petroleum Ether. Boiling point 40°C to 80°C.

D2.2 Benzene-alcohol-

Phenolphthalein Stock Solution.

To one litre of distilled benzene add one litre of alcohol or rectified spirit and 0.4g of phenolphthalein. Mix the content well.

D2.3 Standard Potassium Hydroxide Solution. 0.0SN

D3. PROCEDURE

D3.1 Weigh accurately about 10g of biscuit powder (A.3.3.2) and transfer it to the thimble and plug it from the top with extracted cotton and filter paper. Dry the thimble with the contents for 15 to 30thminutes at 100°C in an oven. Take the weight of empty dry soxhlet flask. Extract the fat in the soxhlet apparatus for 3 to 4 hours and evaporate off the solvent in the flask on a water bath. Remove the traces of the residual solvent by keeping the flask in the hot air oven for about half an hour and weigh. Cool the flask and add 50ml of mixed benzene-alcohol-phenolphthalein reagent (D2.2) and titrate the content of a distinct pink colour with the potassium taken in a 10ml micro burette. If the contents of the flask become cloudy, during titration add another 50ml of the reagent (D2.2) and continue titration. Make a blank titration of the 50ml reagent. Subtract from the tire of the fat, the blank tire.

D4. CALCULATION

D4.1. Acidity of extracted fat (as oleic acid), per cent by mass = 1.41 x V/m1-m

Where

V= Volume of 0.05N potassium hydroxide solution used in titration after subtracting the blank:

m1 = mass in g of Soxhlet flask containing fat, and

m = mass in g of empty Soxhlet flask.

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS019: 2003

CATTLE FEEDS- Specifications

1.    SCOPE

This Zambian Standard prescribes specification for the following dairy cattle feeds:

-   Calf meal

-   Low dairy feed

-   Medium dairy feed

-   High dairy feed

2.    NORMATIVE REFERENCES

The following reference has been made in this standard:

ZS 189-Mealie meal: Roller meal

3.    TERMINOLOGY

3.1 General definitions

3.1.2.1 Feed. A compound mixture of nutritional ingredients intended to be fed without further admixture of other materials.

3.1.2    Concentrate. A compound mixture which, when mixed with ground grain of normal composition in the proportions stated by the manufacturer, produces a resultant feed equal in all respects to the feed of relevant designation as specified in the Table set out in the Appendix.

3.2    DEFINITION OF DESIGNATIONS

3.2.1.1   Calf Feed. A feed suitable for calves and young growing cattle. It is designed to supplement substantial intake of hay or grazing, and for feeding to be continued until adequate nutrition for the class of stock concerned, is obtained from grazing alone or from grazing with alternative forms of supplement.

3.2.1.2   Dairy feed. A feed suitable for lactating dairy cows and is designed to provide the nutritional requirements for milk production when fed at a rate of 450gm of feed per kg of milk (3.8% butterfat) produced.

3.3 Definition of terms

3.3.1   Crude Protein percentage. The percentage of nitrogen multiplied by 6.25. The percentage of nitrogen is to be determined by the standard modified Kjeldahl technique.

3.3.2   Crude fibre percentage. The percentage of cellulose, hemi cellulose and lignin as determined by the method described in appendix C to Zambian Standard ZS 189 Mealie Meal.

3.3.3   Crude fat Percentage. The percentage of ether soluble substances as determined by the method described in Appendix B to Zambian Standard ZS 189 Mealie Meal.

3.3.4   Metabolisable energy. The amount of gross energy contained in the feed after subtracting energy in the faeces and urine, which is available for metabolism of the animal.

4. SPECIFICATION AND REGULATIONS

4.1   General

The following regulations shall apply to all feeds or concentrates:

4.1.1    Quality. Raw materials shall not be in unsound, decomposed or deteriorated condition.

4.1.2    Contamination. Feeds and concentrates shall be free of pathogenic organisms.

4.1.3    Mycotoxis. Raw Material shall contain not more than 2% fungal infected grain.

4.1.4    Urea. Urea or other non-protein nitrogenous substances shall not be incorporated into cattle feeds unless specified.

4.1.5    Free Fatty Acids. The level of free fatty acids (expressed, as oleic acid in feeds shall not exceed 20% of the crude fat content.

4.1.6    Containers and Labelling. Feeds and concentrates shall be packed in containers which are sound and clean and which have not been previously used. Every container shall bear the following particulars printed or indelibly inscribed thereon or upon a label attached thereto or in the case of a bulk delivery upon the invoice delivered with the consignment:

   (a)   Name of manufacturer or brand name;

   (b)   Batch number or code or date of manufacture;

   (c)   Designation of feed or concentrate

   (d)   Declared proportion of Urea, Crude Protein, Crude Fibre and Crude Fat;

   (e)   if a concentrate, the proportion in which it is to be mixed with other materials; and

   (f)   Particulars of additives.

Where labels are used, a duplicate label shall be enclosed within the container.

4.1.7    Vitamins: Vitamin preparations added to cattle feeds, licks or concentrates shall be in a stabilised form.

4.1.8    Designation of Feed and Concentrates. Feed and concentrates shall be designated by the names mentioned in clause 1.

4.1.9    Additives. No additive, antibiotic substance, drug or mineral may be added to or included in a feed or concentrate other than such ingredients required to satisfy the standard specifications shown in the Table:

   (a)   Flavourings designed to improve palatability may be included at the manufacturer’s discretion:

   (b)   Where a consignment or batch of feed or concentrate is prepared specifically for a consumer or group of consumers, substances may be added upon the express written instructions of the consumer, provided that:

      (i)    Such additions are made in accordance with the provisions of the Therapeutic Substances Act, Cap. 310. of the Laws of Zambia, and are not prohibited by any other enactment or statutory regulations.

      (ii)    the natures and quantities of such additions are clearly stated upon each and every container of the feed or concentrate in accordance with clause 3.1.6 above.

4.2.    COMPLIANCE WITH SPECIFICATIONS

Feeds purporting to comply with this standard shall conform to the relevant specification shows in the table. The same specification shall apply pro rata to concentrates according to the terms of the definition in clause 2.2 above.

5.    SAMPLING AND TESTING

5.1    Representative samples shall be drawn according to the methods prescribed in Appendices F, G, H and J to Zambian Standard ZS 189 Mealie meal.

APPENDIX

TABLE CATTLE FEEDS SPECIFICATIONS

Characteristics

Calf meat

High Production daily meal

Medium Production daily meal

Low Production daily meal

Metabolisable Energy Kcl/kg, min

2500

2600

2500

2350

Crude protein per cent min

17

20+

16-19

14-16

Crude fibre per cent min

5.0

7

7

7

Crude fat per cent, max

3

3

3

3

Moisture per cent max

12.0

12.0

12.0

12.0

VITAMIN min.

6000

6000

6000

6000

AIU/kg

600

600

600

600

D3IU/kg

3

3

3

3

EIU/kg

0.9

0.9

0.9

0.9

K3

1.10

1.10

1.10

1.10

Riboflavin, mg/kg

20

20

20

20

Niacin, mg/kg

5.0

5.0

5.0

5.0

Panthothenic acid, mg/kg

       

Folic acid

       

Biotin

440

440

440

440

Chorine, mg/kg

       

MINERALS, min.

       

Manganese, ppm

40

40

40

40

Copper, ppm

10

10

10

10

Iron.ppm

50

50

50

50

Zinc, ppm

40

40

40

40

Selenium, ppm

0.1

0.3

0.3

0.3

Iodine, ppm

0.1

0.6

0.6

0.6

Cobalt, ppm

0.1

0.1

0.1

0.1

Calcium, %

1.2

1.2

1.2

1.2

Phosphorus, %

0.75

0.75

0.7

0.7

Magnesium%

0.3

0.3

0.25

0.25

Salt, %

0.5

0.5

0.5

0.5

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS431: 2003

COMPOUND FERTILIZERS - Specification

1.    SCOPE

This standard specifies requires, sampling and test methods for compound fertilisers.

2.    DEFINITIONS

For the purpose of this document the following definitions apply:

2.1 Fertiliser

Material, the main function of which is to provide plant nutrients.

2.2 Fertiliser blend

Fertiliser containing at least two of the macronutrients obtained by mixing raw materials different in chemical composition. This is done following a specific required proportion of the macronutrients.

2.3 Compound Fertilizer

Fertiliser having a content of at least two of the plant nutrients nitrogen, phosphorus and potassium obtained chemically or by blending or by blending or both.

2.4 Crystals

Particles of chemical substances formed by chemical bonding of molecules. The Particles have a definite and regular shape. Examples of this are salt and sugar crystals.

2.5 Granular fertiliser

Fertiliser having a particle size range of 3mm to 5mm. The particles are manufactured such that they can be easily crushed between the fingers.

2.6 Prilled fertilizer

Fertiliser having a particle size range of 1mm to 3mm. The particles are manufactured such that they can be easily crushed between the fingers.

2.7    Macro-nutrients

The elements nitrogen, phosphorous and potassium.

2.8 Micro-nutrients

Elements such as boron, iron, manganese, Zinc, copper, molybdenum, cobalt or any other nutrient, essential, in relatively small quantities for plant growth.

3   REQUIREMENTS

3.1 Physical requirements

3.1.1 General

Compound fertiliser shall be in the form of granules, prills or crystals. The product shall be homogenous and free flowing.

3.1.2 Partical size

Not less than 90% (m/m) shall be in the particle size range 1mm to 5mm.

3.2 Chemical requirements

Macronutrients. Compound fertiliser shall contain at least two of the macronutrients nitrogen (N), Phosphorus (P) and Potassium (k).

3.2.2 Micronutrients and other nutrients*.

Compound fertiliser shall also contain at least one of the following:

Boron (B)

Iron (Fe)

Molybdenum (Mon)

Calcium (Ca)

Magnesium (Mg)

Sulphur (s)

Copper (Cu)   

Manganese (Mn)

Zinc (Zn)

3.2.3 Specific requirements. Compound fertiliser shall comply with the specifications in tables 1 and 2.

TABLE 1: SPECIFIC REQUIREMENT FOR COMPOUND FERTILIZERS.

Characteristic

Requirement

Method of test

Moisture content, per cent m/n max

1.0

Appendix B.1

pH of 10% solution, min

5.5

Appendix B.3

<FT:Calibri,SN>*magnesium, sulphur and calcium are not micronutrients.

ZS431.2003

TABLE 2 (A): FERTILIZER MIXTURES-SPECIFIC REQUIREMENTS

Compound fertiliser

 

N

P2O5

K2O

B

Zn

B: 4:18:15

Max

5

20

17

4

0.1

 

Min

3

16

13

4

 

C: 6:18:15

Max

8

20

17

4

0.1

 

Min

5

16

13

4

0.1

D: 8:18:15

Max

10

20

17

4

0.1

 

Mini

7

16

13

   

S: 6:18:6

Max

8

20

7

   
 

Min

5

16

5

0.04

 

X: 20:10:5

Max

22

12

6

   
 

Min

18

8

4

   

J: 15:5:20

Max

17

6

22

   
 

Min

13

4

18

   

3:2:1(25)

Max

13

21

6

   
 

Min

10

17

4

4

0.1

23:21:0+45

Max

25

22

 

5

 
 

Min

20

18

 

3

 

0.22:30

Max

 

20

32


{mprestriction ids="2,3,5"}

 

 
 

Min

 

20

28

   

Diammonium

           

Phosphate

Max

19

48

   

0.15

(DAP)

Min

17

44

     

Mommonium

           

Phosphate (MAP)

Max

12

52

   

0.15

Super B

Max

6

26

22

   

(5:24:20)

Min

4

22

18

6

0.15

Supper C

Max

10

26

22

   

(8:24:20)

Min

6

22

18

6

0.15

Super D

Max

12

26

22

 

0.15

(10:24:20)

Min

9

22

18

6

 

(10:24:20)

Max

12

22

22

   

20:20:5+45+

Min

8

8

18

18

 

0.1 Zn

Max

22

22

6

6

0.1

 

Min

18

18

4

   

3.2.4 Calcium nitrate (15.5%N + 19.0% calcium) (water soluble urea – S(8:1) (40%N + 5%SO).

3.2.5 Fertilisers for use in the tobacco fields shall not contain chlorine more than 2% m/m.

3.2.6 Bulk blending: Bulk blending results in serious heterogeneity and must be avoided as much as possible.

In any case, where bulk blending has to be practised, the different raw materials used shall be of equivalent particle sizes and densities and wherever possible, from the same fertiliser plant.

4.    PACKING AND MAKING

4.1 Packing.

Compound fertilisers shall be packed in clean, sound and strong containers. The material from which the container is made shall be such as to protect the contents from moisture and also not lead to easy rupture during handling, transportation and storage.

The quantity of compound fertiliser normally packed in a container shall not exceed 50Kg net mass. Polypropylene bags with an interlinings shall be used for all packages of 20Kg or above, plastic bags can only be used for packages less than 20Kg.

4.2 Making

Each container of compound fertiliser shall bear a label in indelible marking with the following particulars:

   (a)   name of product;

   (b)   name of manufacturer and/or registered trade mark or name;

   (c)   list and guaranteed percentages by mass of each of the macro-nutrients present. If the nutrients percentages are expressed in the conventional sequence N-P-K, then they need not be named. However, if the nutrients are expressed in the form of N-P2O5-K2O5, that is oxides, and then they shall be named.

   (d)   Name and guaranteed percentage of any other nutrients elements present;

   (e)   Net mass, in kg;

   (f)   Lot identification;

   (g)   Type of crops for which the fertiliser shall be used;

   (h)   Country of origin;

      (i)   Caution statement-not to be taken-keep out of reach of children, and

   (j)   Any other marking required by the country of origin or destination.

4.2.1 Bulk container. Where product is distributed in bulk, the marking information shall accompany the delivery notice to the purchaser.

4.2.2 Certificate of analysis. A certificate of analysis stating the minimum percentage levels of plant nutrients elements magnesium and sulphur shall accompany every lot or consignment of compound fertiliser. It shall also state:

   (a)   the form in which nitrogen is present;

   (b)   the percentage of water soluble phosphates;

   (c)   the form in which Potassium is present.

5.     STORAGE AND HANDLING

Storage and handling of compound fertiliser shall be in accordance with the stipulations in ZS545-Bagged fertilizers-Handing and storage – Code of Practice.

6.  SAMPLING AND METHODS OF TEST

Sampling and testing for compliance to this specification shall be done as outlined in the Appendix.

7.  COMPLIANCE

The lot shall be deemed to comply with the Standard if after inspection and testing it complies with the requirements in this document.

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS2447: 2003

HOUSEHOLD HAND DISH WASHING LIQUID DETERGENT - SPECIFICATION

1.    SCOPE

This Zambians Standard specifies the requirements for liquid detergent compositions used for the hand washing of dishes and similar items used for domestic food preparation and consumption.

2.    REFERENCES

The following publication has been referred to in this Standard:

ZS222: Methods of analysis for synthetic detergents*.

3.    GENERAL REQUIREMENTS

3.1 Foam

The detergent shall be a homogenous liquid free from foreign matter and may contain added materials such as colouring agents, perfumes, opacifiers, viscosity controlling agent, form control agents, solubilizers and preservatives.

NOTE: Dyestuffs that have been approved by the Ministry of Health, may be assumed to have a sufficiently low toxicity for use in liquid detergents.

3.2 Effect of health

When used in accordance with the manufacture’s directions or in normal household use, the detergent shall not be injurious to health.

3.3 Miscibility with water

The detergent shall be readily miscible with water.

3.4 Biodegradability

Each surfactant in the detergent shall be biologically soft.

3.5 Odour

Neither the detergent nor a solution of the detergent in water at 60 + 20°C shall have an objectionable odour.

3.6 Residual taste

The detergent shall not leave any residual taste on washed articles described in clause 1.

3.7 Storage properties

The detergent shall be capable of meeting the requirements of this specification after storage in its original sealed container at normal ambient temperatures for a period of at least 12 months from the date of manufacture.

3.8 Rinsing properties

When tested in accordance with Annex A, the detergent shall be free rinsing.

4.  SPECIAL REQUIREMENTS

The detergent shall not contain less than 10 percent by mass of total surfactants (active matter) when determined by the methods specified in ZS 222: Part 5.

5. PACKING AND MARKING

5.1. Packaging

5.1.1 The detergent shall be packed in individual containers that do not react with the detergent, are securely closed and are sufficiently strong to prevent leakage arising from the ordinary risk of transportation and handling and storage of the detergent.

5.1.2 When tested by the method described in Annex B, the container of the detergent shall show no sign of leakage. Glass containers shall be exempted from this test.

5.2 Marking

Every container shall be legible marked with the following information:

   (a)   name and address of the person or company assuming responsibility for the product;

   (b)   the date of manufacture (month and year);

   (c)   type of product of brand name; and

   (d)   instructions for use of products.

6.     SAMPLING AND TEST

Sampling, preparation of gross and test samples and the criteria for conformity shall be specified in ZS 222.

APPENDIX A

A.1 PREPARATION OF STANDARD HARD WATER

Dissolve 0.220g pure Calcium Chloride (CaCl2 2H2O) and 0.24g of pure magnesium sulphate (MgSO4 7H2O) in distilled water and dilute to 5 litres with distilled water. (This standard hard water has a hardness of about 50 ppm calculated as calcium carbonate).

A.2 PROCEDURE

A.2.1 Using a syringe, pipette 0.4 ml of the sample into thoroughly cleaned 500ml flask. Add 200ml of the standard water prepared as described in A1. Stopper the flask and shake vigorously for 1 minute.

A.2.2 Pour out solution and rinse the flask by adding 200ml of the standard hard water and shaking vigorously for 1 minute. Repeat this rinsing once more. Invert the flask and allow to dry.

A.2.3 Carry out a blank determination by repeating the above procedure but omitting the sample.

A.2.4 Compare the two flasks.

A.3 REQUIREMENT

The product is considered to be free rinsing if the sediment, streaks and marks on the flask used for the test do not exceed those on the flask used in the blank determination.

APPENDIX B

DETERMINATION OF IMPACT RESISTANCE

B.1 The container shall be filled to its normal capacity with the detergent it is to hold, then closed in the normal manner and conditioned for 1 hour at 38 + 3°C.

B.2 The container shall then be dropped five times from a height of 1.25m to an unyielding surface and shall then be examined for signs of leakage.

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS 005: 2003

LEAD-ACIDS STARTER BATTERIES-SPECIFICATION

1.  SCOPE

This Zambian Standard specifies standard characteristics, methods of test and test requirements for lead-acid (accumulator) batteries with a nominal voltage of 6V or 12V, used primarily as a source of starting and ignition current for internal combustion engine vehicles. These batteries are commonly called starter batteries.

This standard does not apply to batteries for other purposes such as starting of railcar internal combustion engine.

2.  DEFINITIONS

For the purpose of this Zambian Standard the following definitions apply:

2.1 New battery. An unused battery less than 60 days old from the date of manufacture.

2.2 Dry charged battery. A battery that contains charged plates but no electrolyte, than may be activated by the addition of suitable electrolyte.

2.3 Conserved charged battery. A battery that when supplied contain only a small quantity of electrolyte, mainly absorbed within the plates and separators. The plates are in a charged condition and the battery is activated by the addition of further electrolyte.

2.4 Nominal voltage. The characteristic voltage of the lead-acid system, (2V). multiplied by the number of cells in series.

2.5 Electrolyte density. The mass in kilogrammes of 1M3 of electrolyte at 25°C.

2.6 Reserve capacity. The period during which the battery can supply a constant current of 25A down to an end voltage of 1.75 per cell at 25°C. This current is based on a typical total electrical load of a vehicle such as would be carried by the battery under adverse driving conditions in the event of failure of the generation system.

2.7 Cranking performance. Assessed performance under simulated starting load conditions.

2.8 Endurance test. Determination of the ability of a battery to maintain a satisfactory performance under the conditions specified in the test.

3.  CHARACTERISTICS OF STARTER BATTERIES

Starter batteries shall have the following characteristics:

   (a)   nominal voltage: 6V or 12V;

   (b)   reserve capacity in accordance with clause C.2;

   (c)   cranking performance in accordance with either Appendix D or E;

   (d)   terminal marking in accordance with clause 5.2; and

   (e)   dimensions of batteries.

4.  DECLARATION OF FUNCTIONAL CHARACTERISTICS

The following functional characteristics shall be declared by the battery manufacturer:

   (a)   reserve capacity (in minutes); and

   (b)   (cranking performance (in amperes).

5.  MARKING

5.1 General. Batteries shall be marked so as to show;

   (a)   nominal voltage in accordance with clause 3(a);

   (b)   date of manufacture;

   (c)   type reference of the battery.

NOTE:

The above requirements may be designated by a code. Manufacturer using a code must make it freely available to any interested party, with full details of battery performance.

5.1 Polarity of terminals. Terminals shall be marked in such a way that the positive terminal is clearly indicated.

Marking of the positive terminal shall take the form of a plus symbol (+), either indented or in relief, on the upper surface of the terminal or on the lid adjacent to it. The length of each line of the plus symbol shall be at least 5.6mm.

NOTE:

If the negative symbol is also to be marked, it should be marked in the same way as the positive terminal using a minus symbol (-) of length at least 5.6 mm.

5.2 Certification Mark. The Certification Mark shown below may be used by the manufacturers under licence from the Zambia Bureau of Standards. The presence of this mark on a product is an assurance to the consumers that the goods have been produced to comply with the requirements of this Zambia Standard under a system of supervision, control and testing operates operated during manufacture and including periodical inspections at the manufacturer’s works in accordance with the Certification Marks Scheme.

6.  TESTS

6.1 General. When preparing for tests, the electrolyte shall be used in accordance with Appendix A. Measuring instruments for use throughout the test shall be in accordance with Appendix B.

6.2 Sequence of testing. The sequence of tests shall be as below:

   (a)   Reserve capacity in accordance with Appendix C;

   (b)   Cranking performance in accordance with either Appendix D or E as appropriate;

   (c)   Overcharge endurance in accordance with Appendix F (optional).

6.3 Condition of battery before testing. Unless otherwise stated, as for example in the activation of dry-charged batteries, all test shall be carried out on new, fully charged batteries.

6.4 Fully charged battery. A battery is considered to be fully charged when, at a charging current of 0.05 multiplied by reserve capacity. Its terminal voltage and the density of the electrolyte do not vary appreciably during two consecutive hours.

During this charge, the electrolyte temperature shall be maintained between 15°C and 35°C measured in one of central cells.

The density and level of the electrolyte shall be made up to the values specified by the manufacturer when the cells bubble and the voltage are stabilised.

ZS 005: 2003

APPENDIX A

ELECTROLYTE

A.1 COMPOSITION OF THE ELECTROLYTE

The electrolyte of starter batteries is accumulator sulphuric acid, free from harmful matter.

A.2 DENSITY OF THE ELECTROLYTE

The density of electrolyte shall be measured at a temperature of 25°C and with the battery in the fully charged state.

A.3 DENSITY FOR TEST ACCEPTANCE

For the purpose of the tests of acceptance prescribed in this standard the density measured as per clause A.2 shall be 1245.

A.4 SPECIFIC GRAVITIES IN SERVICE

Batteries shall be placed in service in accordance with the manufacturer’s instructions. Their density, measured in accordance with A.2 shall be 1240.

A.5 ELECTROLYTE LEVEL

The electrolyte level in the fully charged state for all tests shall be maintained at the level recommended by the manufacturer.

ZS 005: 2003

APPENDIX B

ACCURACY OF MEASURING INSTRUMENTS

B.1 GENERAL

All instruments and measuring equipment shall be calibrated according to the accuracy necessary for the tests.

B.2 ELECTRICAL MEASURING INSTRUMENTS

B.2.1 General. The range of instruments used shall be appropriate for the magnitude of the voltage or current to be measured.

NOTE: In general this means for analogue instruments that readings should be taken in the top third of the scale. However, this does not necessarily apply for suppressed zero analogue or digital instruments.

The accuracy of calibration of digital instruments shall be at least as good as that specified for analogue instruments.

B.2.3 Voltmeters. Analogue voltmeters shall have an accuracy of class 1 or better. The resistance of the voltmeters shall be at least 300 ohms per volt.

B.2.4 Ammeters. Analogue ammeters shall have an accuracy of class 1 or better. The assembly of ammeters, shunt and leads shall have an overall accuracy of class 1 or better.

B.3 TEMPERATURE MEASUREMENT

The thermometers used for measuring temperatures shall have an appropriate range and the value of each scale division shall not be greater than 1°C. The accuracy of the calibration of the instruments shall not be less than 0.5°C.

B.4 DENSITY MEASUREMENTS

The density of the electrolyte should be measured with hydrometers furnished with a graduated scale of which the value of each division is equal to, at most, 0.005 units of density. The accuracy of calibration shall be to 0.005 units of density or better.

B.5 TIME MEASUREMENT

Instruments for measuring time (or elapsed time) shall be graduated in seconds, minutes and hours as appropriate and shall have accuracy of at least 0.95% or 1 whichever or 1 s whichever is the greater period.

ZS 005: 2003

APPENDIX C

RESERVE CAPACITY TEST

C.1 The test is carried out on a new fully charged battery.

C.2 The battery, at a temperature of 25 ± 2°C, measured in a central cell, is discharged continuously at a current of 25 ±0.25 A down to an end voltage equivalent to 1.75V per cell. The duration of the discharge, B in minutes, shall be equal to or greater than the value declared by the manufacturer.

C.3 When the test is finished, the battery should be recharged. The test should not be carried out more than three times on the same battery.

ZS 005: 2003

APPENDIX D

CRANKING PERFORMANCE TEST ON ACTIVATED BATTERIES

D.1 The test is carried out on a new fully charged battery.

D.2 The battery is allowed to stabilise at a temperature of ± 2°C, measured in a central cell. Temperature conditioning shall take place over a period of up to 24h, including a stabilisation period of 8 h at the test temperature.

D.3 The battery is then discharged at a current I as stated by the manufacturer for a time of 5 minutes. The final voltage shall be equal to or greater than 8V in the case of a 12V battery, or 4 in the case of a 6V battery.

D.4 After completing the test, the battery is allowed to regain ambient temperature and then fully recharge immediately afterwards.

ZS 005: 2003

APPENDIX E

CRACKING PERFORMANCE TEST ON DRY-CHARGED OR CONSERVE-CHARGED BATTERIES

E. 1 TEST ON NEW BATTERIES

E.1.1 The test is carried out on a new battery less than 60 days after manufacture, and which has been stored at an ambient temperature of 25 ± 10°C with a relative humidity not exceeding 80%.

E.1.2 The battery and electrolyte at a density of 1245 or at the density specified by the manufacturer is placed in an enclosure at a temperature of 25 ± 2°C for at least 18 h.

E.1.3 The battery is then removed from the enclosure and immediately filled with electrolyte at the same temperature of 25 ± 2°C.

E.1.4 The battery is allowed to rest for 20 minutes after filling.

E.1.5 The battery is discharged at a current I as stated by the manufacturer.

The average voltage per cell is noted after 180s discharge. This voltage shall be greater than 1 V per cell on average.

E.1.6 After completing this test, the battery should be recharged. It can then be subjected to the same tests as batteries supplied ready for use.

E.2 TESTS ON STORED BATTERIES

E.2.1 Batteries subjected to this test shall have been stored for 12 months from the date of manufacture, in an ambient temperature of 25 ± 10°C with a relative humidity not exceeding 80%.

E.2.2 Subject the battery to tests specified in E.1.2 to E.1.5. The average voltage percentage cell is noted after 120s discharged. This voltage shall be greater than 1 V per cell on average.

ZS 005: 2003

APPENDIX F

OVERCHARGE ENDURANCE TEST

F.1 The test is carried out on a new fully charged battery.

F.2 The batter is placed in a trough of water at a temperature 40 ± 2°C and charged for 100h at a constant rate of 0.05 multiplied by reserve capacity. The battery container shall project not more than 25mm above the surface of water. If several batteries are placed in the trough, the minimum distance between the batteries and the walls of the trough shall be at least 25mm. The electrolyte levels in the cells shall be readjusted daily.

F.3 After this overcharge period, the battery remains on open circuit in the trough at a temperature 40 ± 2°C for a period of 68h.

F.4 At the end of this time, and still at temperature 40 ± 2°C the battery is subjected, without previous recharging, to a rapid discharged test down to an average voltage of 1.33V per cell. The duration of this discharge is noted. This duration shall be equal to or greater than 240s.

F.5 Repeat the test sequence F.2 to F.4 without previous recharging, until a total of four units of overcharging has been successfully achieved.

F.6 After this test, the battery should not be subjected to any other test.

ZS 018: 2003

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS 01: 2003

PIG FEEDS: SPECIFICATION

1. SCOPE

This Zambia Standard prescribes specifications of the following pig feeds:

   (a)   Creep feed;

   (b)   Grower feed;

   (c)   Finisher/baconer feed

   (d)   Lactating sow feed; and

   (e)   Dry sow, boar and gilt feed.

2. REFERENCE

The following reference has been made in this Standard:

ZS 189 mealie meal. Roller meal.

3. TERMINOLOGY

3.1 Definition of feeds

3.1.1 Pig creep feed. A feed suitable for piglets up to the normal weaning age of eight weeks.

3.1.2 Pig growers feed. A feed suitable for growing pigs from approximately eight weeks until they have reached a live weight of approximately 55kg.

3.1.3 Pig finisher feed. A feed suitable for pigs of more than 55kg, which are intended for slaughter.

3.1.4 Dry sow, boar and gilt feed. A feed suitable for breeding pigs of both sexes and of more than 55kg live weight.

3.1.5 Lactating sow feed. A feed suitable for lactating sows.

3.1.6 Concentrate. A compound mixture which, when mixed with maize-meal or any other source of carbohydrate in the proportions stated by the manufacturer, produces a resultant feed equal in all respects to the feed or relevant designation as specified in the table set in the Appendix.

3.2 Definition of terms

3.2.1 Crude protein percentage of a feed. The percentage of nitrogen in a feed multiplied by 6.25. The percentage of nitrogen is to be determined by the standard modified kjeldahl technique.

3.2.2 Crude fibre percentage of a feed. The percentage of cellulose, hemicelluloses and lignin as determined by the method described in Appendix C to ZS 189.

3.2.3 Crude fat percentage of a feed. The percentage of either soluble substances as determined by the method described in Appendix B to ZS 189.

3.2.4 Metabolisable energy. The amount of energy contained in the feed and that is available for Utilisation by the pig (i.e. less the energy lost in faeces).

3.2.5 Moisture content. This shall be determined by the method described in Appendix A of ZS 189. Statement of the quantities of constituents specified in this Standard assume a maximum moisture content of 12% in the compound feed or concentrates.

4. SPECIFICATIONS AND REGULATIONS

4.1 General. The following regulations shall apply to all feeds or concentrates purporting to comply with this standard.

4.1.1 Quality. Raw materials shall not be in an unsound, decomposed or deteriorated condition.

4.1.2 Contamination. Feeds and concentrates shall be free of pathogenic Organisms or any foreign materials.

4.1.3 Mycotoxins. Raw materials shall contain not more than 2% of fungal infested/infected grain.

4.1.4 Oilseeds and their by-products:

4.1.4.1 Feed shall contain not more than 0.02% of gossypol.

4.1.4.2 Soya bean meal which has not been subjected to correct heat treatment as measured by the urease activity, shall not be used in pig feed or concentrates.

4.1.4.3 The urease activity shall be between 0.1 and 0.3%.

4.1.5 Free fatty acids. The level of free fat acids in feeds shall not exceed 15% of the crude fat content at the time of manufacture.

4.1.6 Containers and labelling. Feeds shall be packed in containers which are sound and clean and which have not previously been used. Every container shall bear the following particulars printed or indelibly inscribed thereon or upon the invoice delivered with the consignment; where labels are used, a duplicate label shall be enclosed within the container:

   (a)   name of manufacturer or brand name;

   (b)   batch number or code and date of manufacture;

   (c)   designation of the feed;

   (d)   declare proportions of crude protein, crude fibre fat, phosphorus, calcium;

   (e)   if a concentrate, the proportion in which to be mixed with maize meal;

   (f)   particulars of additives; and

   (g)   the Certification Mark of the Zambia Bureau of Standards.

NOTE. For more information about the certification Mark, write to the Zambia Bureau of Standards.

4.1.7 Vitamins. Vitamin preparations added to pig feeds shall be in a stabilised form.

4.1.8 Designation of feeds and concentrates. Feeds shall be designated by the names mentioned in clause 1 above and by no other or alternative name.

4.1.9 Additives. No additives, antibiotic substance, drug or mineral may be added to or included in a feed other than such ingredients required to be added to or included in a feed to satisfy the standard specification shown in the Table except–

   (a)   flavourings designed to improve the palatability of the feed which may be included at the manufacturer’s discretion; or

   (b)   where a consignment or a batch of feed or concentrate is prepared specifically for a consumer or group of consumers, where substances may be added upon the express written instructions of the consumer provided that–

      (i)    such additions are made in accordance with the provisions of the Therapeutic Substances Act, Cap. 550, of the Laws of Zambia, and are not prohibited by any other enactment or statutory regulations; and

      (ii)    the nature and quantities of such additions are clearly stated upon each and every container of the feed or concentrate, in accordance with 4.1.6 above.

4.2 Compliance with specifications. Feeds purporting to comply with this Standard shall conform to the relevant specifications shown in the Table. The same specifications shall apply pro rata to concentrates according to the terms of the definition in 3.1.6 above.

5. SAMPLING AND TESTING

5.1 Representative samples shall be drawn according to the methods prescribed in Appendices F, G, H and J-ZS 189 to Meali Meal: Roller meal.

APPENDIX

TABLE NUTRITIONAL REQUIREMENTS FOR PIG FEEDS

Type of feed

Creep feed

Grower feed

Finisher Baconer

Lactating feed

Dry sow, boar and sow gilt feed

Metabolisable energy

         

MJ/kg. Min.

12

12.5

13

13.7

11.0

Crude Protein%, min.

20

18

15

16

12.0

Crude Fat per cent, max.

7.0

7.0

7.0

7.0

7.0

Crude Fibre %% max.

5

7

8

7

8

Moisture per cent, max.

12

12

12

12

12

Amino Acids

         

Lysine per cent, min.

0.85

0.80

0.6

0.6

0.45

Methionine per cent, min.

0.4

0.25

0.2

0.25

0.2

Vitamins

         

Roboflavin mg/kg, min.

3.5

3

2.5

2

4

Pantothenic acid mg/kg, min.

10

9

8

7

12

Niacin mg/kg, min.

15

12.50

10

7

10

Folic acid mg/kg, min.

0.3

15

0.3

0.3

0.3

B12ug/kg, min.

17.5

3

10

15

10

AIU/kg, min.

2,200

1.750

1,300

2000

2000

D3IU/kg, min.

220

200

150

200

200

EIU/kg, min.

16

11

11

22

11

K mg/kg, min.

0.5

0.5

0.5

0.5

0.5

Minerals

         

Calcium per cent, max.

1.25

1.25

1.25

1.25

1.25

Total Phosphorus per cent, min.

0.6

0.55

0.45

0.55

045

Available

         

Phosphorus per cent, min.

0.4

0.35

0.30

0.35

0.3

Manganese mg, kg, min.

4

4

4

4

4

Iodine mg/kg, min

0.1

0.1

0.1

0.1

0.1

Zinc mg/kg, min.

100

100

80

60

50

Iron mg/kg, min.

100

80

80

80

80

Copper mg/kg. Min

15

15

20

20

20

Selenium mg/kg, min

0.3

0.25

0.15

0.15

0.1

NOTE: The calcium to phosphorus ratio is recommended to be in the range of 1.0 –1.75:1. Rates in excess of 1.25% should be avoided.

ZS 017: 2003

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS 017: 2003

POULTRY FEEDS - SPECIFICATION

1. SCOPE

This Zambian Standard prescribes specifications for the following poultry feeds:

   (a)   Broiler feed

-broiler starter

-broiler grower

-broiler finisher

   (b)   Layer feed

- pullet            - pullet grower

- layer pre-lay         -layer phase 1

- layer phase 2      -high energy layer feed

2. REFERENCES

The following reference has been made in this Standard – ZS 189 – Mealie Meal: Roller meal.

3.TERMINOLOGY

3.1 Definition of feeds

3.1.1 Broiler starter feed. A feed suitable for meat type chickens up to three to four weeks of age containing all nutritional requirements.

3.1.2 Broiler grower feed. A feed suitable for meat type chicken from three to four weeks until slaughter or until finisher feed is used.

3.1.3 Broiler finisher feed. A feed suitable for meat type from four to five weeks of age until slaughter, containing all nutritional requirements.

3.1.4 Pullet starter feed. A feed suitable for chickens which are not intended for meat production, from day-old until eight weeks of age, containing all nutritional requirements.

3.1.5 Pullet grower feed. A feed suitable for growing poultry other than meat-type birds from eight weeks of age until two weeks before point of lay, containing all nutritional requirements.

3.1.6 Pre-lay feed. A feed suitable for point of lay poultry from 18 to 20 weeks containing all nutritional requirement under normal conditions.

3.1.7 Layer phase 1 feed. A feed suitable for egg production from 20 to 50 weeks containing all nutritional requirements under normal conditions.

3.1.8 Layer phase 2 feed. A feed suitable for egg production from 50 weeks to depletion containing all the nutritional requirement under normal conditions.

3.1.9 High energy layer feed. A feed suitable for egg production from two weeks before point of lay and throughout the laying period, containing all nutritional requirements under normal conditions. The energy shall be higher than layer phase 1 feed.

3.1.10 Concentrate. A compound mixture which, when with ground grain of normal composition in the proportions stated by the manufacturer, produces a resultant feed equal in all respects to the feed of relevant designation as specified in tables 1 and 2 set out in the appendix.

3.3 Definition of terms

3.2.1 Crude protein percentage of a feed. The percentage of nitrogen in a feed multiplied by 6.25. The percentage of nitrogen is to be determined by the standard modified kjeldahl technique.

3.2.2 Crude fibre percentage of a feed. The percentage of cellulose, hemi cellulose and lignin as determined by the method described in Appendix C to ZS 189.

3.2.3 Crude fat percentage of a feed. The percentage of either soluble substances as determined by the method described in Appendix B to ZS 189.

3.2.4 Metabolisable. The amount of energy contained in the feed and that is available for Utilisation by the pig (less the energy lost in the faeces).

3.2.5 Total digestible nutrients (TDN). The sum of the percentages of digestible crude protein, digestible crude fibre, digestible nitrogen-feed extracts and 2.25times the percentage of digestible crude fat. The TDN of a compound feed shall be calculated as the sum of the TDN values of the separate ingredient. The later values shall be determined by the sample analysis and application of digestibility coefficients which shall be those quoted by generally accepted authorities.

3.2.6 Total ash and acid insoluble ash. These shall be determined by the methods described in Appendices D and E of ZS 189.

3.2.7 Moisture content. This shall be determined by the method described in appendix A of ZS 189. Statement of the quantities of constituents specified in this standard assume nominal moisture content of 10% in the compound fee or concentrates.

4. SPECIFICATIONS AND REGULATIONS

4.1 General. The following regulations shall apply to all feeds or concentrates.

4.1.1 Quality. All ingredients and raw materials shall be of high quality and shall not be in an unsound, decomposed or deteriorated condition.

4.1.2 Contamination. Feeds and concentrates shall be free of pathogenic organisms.

4.1.3 Mycotoxin. Raw materials shall contain not more than 2% fungal infected grain.

4.1.4 Oilseeds and their by-products:

4.1.4.1 Whole or ground cotton seed shall not comprise more than 5% of a feed, and no feed shall contain more than 0.02% of gossypol.

4.1.4.2 Ground raw Soya bean seed or Soya bean cake meal, which has not been subjected to correct heat treatment as measured by the urease activity shall not be used in poultry feed or concentrate. The urease activity shall be between 0.1 and 0.3%.

4.1.1.3 Linseed meal shall not be included in poultry feeds.

4.1.5 Free fatty acids. The level of free fatty acid (expressed as oleic acid) in feeds shall not exceed 10% of the crude fat content at the time of manufacture.

4.1.6 Containers and labelling. Feeds and concentrates shall be packed in containers which are sound and clean and which have not previously been used. Every container shall bear the following particulars printed or indelibly inscribed thereon or upon the invoice delivered with the consignment; where labels are used, a duplicate label shall be enclosed within the container:

   (a)   name of manufacturer and brand name;

   (b)   batch number or code and date of manufacture;

   (c)   designation of the feed or concentrate;

   (d)   declared proportions of crude protein, crude fibre, crude fat, phosphorus, calcium, moisture;

   (e)   if a concentrate, the proportion in which it is to be mixed with ground grain.

   (f)   Generic name and level of coccidiostat added in feed with a warning i.e not suitable for; and

   (g)   The certification mark of the Zambia Bureau of Standards, where applicable.

4.1.7 Vitamins. Vitamin preparations added to poultry feeds shall be in a stabilised form.

4.1.8 Nitrogenous substance. Urea or any other nitrogenous substances shall not be added to or included in any poultry feed, except such true protein, amino acids, vitamins etc., which are specified in this standard.

4.1.9 Additives. No additives, antibiotic substances, drug or mineral may be added to or included in a feed or concentrate other than such ingredients required to satisfy the standard specification shown in Tables 1 and 2 except–

   (a)   egg yoke colouring of flavourings designed to improve the palatability of the feed which may be included at the manufacturer’s discretion;

   (b)   where a consignment or a batch of feed or concentrate is prepared specifically for a consumer or group of consumers, substances may be added upon the express written instruments of the consumer, provided that–

      (i)    such additions are made in accordance with the provision of the Therapeutic Substances Act, of the Laws of Zambia, and are not prohibited by any other enactment or statutory regulation; and

      (ii)    the nature and quantities of such additions are clearly stated upon each and every container of the feed or concentrate, in accordance with 3.1.7 above.

4.2 Feeds complying with this standard shall conform to the relevant specifications shown in Tables 1 and 2. The same specification shall apply pro rata to concentrates according to the terms of the definition in 3.1.7 above.

5. SAMPLING AND TESTING

5.1 Representative samples shall be drawn according to the methods prescribed in Appendices F, G, H and J to ZS 189.

ZS 017: 2003

APPENDIX

TABLE 1 NUTRITIONAL REQUIREMENTS FOR BROILER FEED

Age of the birds (Week)

Starter (0-21 days)

Grower (22-37 Days)

Finisher 38 days to Market

Crude protein per cent min

22

19

18

Metabolizable Energy mj/kg

     

Kcal/kg

12

12.5

12.5

Moisture per cent, max

2870

3000

3100

Calorie: Protein ration

12

12

12

Crude fat per cent, max

135

160

182

Linoleic Acid per cent, max

5

7

9

Crude fibre, per cent (max)

1

1

1

Coccidiostat

5

5

5

Minerals

+

+

+

Calcium, %min

0.9

0.9

0.9

Total Phosphorus, per cent min

0.42

0.42

0.42

Salt%

0.30-0.45

0.30-0.45

0.30-0.45

Sodium per cent, min

0.18

0.18

0.18

Potassium per cent, min

0.65

0.65

0.65

Magnesium per cent, min

0.06

0.06

0.06

Chloride %

0.18-0.27

0.18-0.27

0.18-0.27

Amino Acids (% min)

     

Arginine

1.28

1.28

0.96

Lysine

1.2

1.01

0.94

Methionine

0.47

0.44

0.38

Methionine + Cystine

0.92

0.82

0.77

Tryptophan

0.22

0.19

0.18

Threonine

0.78

0.76

0.7

Trace Minerals

     

Manganese mg/kg. Min

100

100

100

Zinc mg/kg. min.

75

75

75

Iron mg/kg, min.

100

100

100

Copper mg/kg, min.

8

88

 

Iodine mg/kg, min.

4.45

0.45

0.45

Selenium mg/kg, min.

0.3

0.3

0.3

Vitamins

     

Vitamins iu/kg, min.

9000

9000

7500

Vitamin D3 iu/kg, min.

3300

3300

3300

Vitamin E iu/kg, min.

30

30

30

Vitamin K as K3 mg/kg, min

2.2

2.0

1.65

Thiamine mg/kg, min.

2.2

2.2

2.65

Riboflavin mg/kg, min.

8

8

6

Panthonic Acid mg/kg, min.

12

12

9

Niacin mg/kg, min.

66

66

50

Pyridoxine mg/kg, min.

4.4

4.4

3

Folic Acid mg/kg, min

1

1

0.75

Chlorine mg/kg, min

550

550

440

Vitamin B mg/kg, min.

0.022

0.022

0.015

Biotin mg/kg, min.

0.2

0.2

0.15

<FT:Calibri,SN>ZS 017: 2003

TABLE: 2 NUTRITIONAL REQUIREMENTS FOR LAYER FEED

Type of feed

Pullet starter

Pullet Grower

Pre-lay

Layer 1

Layer 2

Age of birds (weeks)

0-8

0-15

15-18

18-60

>60

Metabolisable Energy

11.5

11.3

11.5

11.5

11.3

(min), MJ/kg kcal/kg

2750

2700

2750

2750

2700

Crude Protein per cent, min.

19

15

16

17

16

Crude Fat per cent, max

5

5

6

6

6

Crude Fibre per cent, max.

5

7

8

8

8

Moisture per cent, max

12

12

12

12

12

Total Amino Acids (%, min)

         

Lysine

0.95

0.65

0.70

0.790

0.70

Methionine

0.4

0.3

0.34

0.38

0.34

Methionine and Cystine

0.7

0.56

0.62

0.67

0.58

Tryptophan

0.22

0.16

0.17

0.19

0.17

Threonine

0.7

0.5

0.55

0.6

0.55

Fatty Acid (%, min)

         

Linoleic Acid

1.25

1.0

>1.30

>1.30

>1.30

Mineral (%, min)

         

Calcium

0.9

0.9

2.5

3.60

3.60

Total Phosphorous

0.6

0.6

0.6

0.6

0.6

Available phosphorus

0.45

0.4

0.4

0.4

0.4

Sodium

0.14-0.18

0.14-0.18

0.14-0.18

0.14-0.18

0.14-0.18

Salt

0.35-0.46

0.35-046

0.35-0.46

0.35-0.46

0.35-0.46

Added Minerals (mg/kg, min)

         

Manganese

100

100

100

100

100

Zinc

80

80

80

80

80

Iron

20

20

20

20

20

Copper

8

8

8

8

8

Iodine

1

1

1

1

1

Selenium

0.2

0.2

0.2

0.2

0.2

Added Vitamins (min)

         

Vitamin A (iu/kg)

10000

8000

8000

12,000

12,000

Vitamin D3 (iu/kg)

3000

2400

3000

3000

3000

Vitamin E (iu/kg)

20

20

25

25

25

Vitamin K (mg/kg)

3

2

2

2

2

Thiamine (B1) (mg/kg)

2

2

2

2

2

Riboflavin (B2) (mg/kg)

6

4

6

6

6

Pyridoxine (B6) (mcg/kg)

20

10

10

10

10

Vitamin B12 (mcg/kg)

20

10

20

20

20

Biotin (mcg/kg)

200

200

200

200

200

Folic Acid (mg/kg)

1.5

1

1

1

1

Niacin (mg/kg)

30

30

30

30

30

*chlorine Chloride (mg/kg)

400

300

450

450

450

Pantothenic Acid (mg/kg)

12

8

8

8

8

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS 234:2003

REFINED EDIBLE VEGETABLE OILS – SPECIFICATION

1. SCOPE

The Zambian Standard specifies the requirements for refined edible vegetable oils.

2. NORMATIVE REFERENCES

The following publications have been referred to in this Zambian Standard:

ZS 002: Methods of Sampling for fats and fatty oils;

ZS 034: Code of practice for general principles of good hygiene;

ZS 226: Methods of test for oils and fats;

Part 1: Chemical tests

Part 2 Physical tests

3. DEFINITIONS

For the purpose of this Zambian Standard, the following definitions and those in ZS 226: Part I shall apply:

<FT:Calibri,SN>Food additive. Any substance nor normally consumed as food by itself and not normally used as a typical ingredient of the food, irrespective of its nutritive value, the intentional addition of which food for a technological purpose in the manufacture, processing, preparation, treatment, packing, transport or holding of such food results or may be reasonably expected to result directly and/or indirectly in it or its by-products becoming a component of or otherwise affecting the characteristics of such foods.

<FT:Calibri,SN>Refined oil. Refined oil shall be the product that has been subjected to a process of purification and neutralisation any may be, depending upon the crude oil, subject to a process of de-colourisation, de-odourisation and winterization.

4. DESCRIPTION

4.1 The material shall be obtained from good quality groundnuts (Arachis hypogea), cotton seeds (Gossypium spp.) sunflower seeds (Helianthus annuus), Soya beans (Glycine max) their cakes or kernels by a process of expression or solvent extraction.

4.2 Solvent extracted oil shall be obtained from oleaginous material using any suitable food grade solvent.

4.3    The oil shall consist of either pure refined:

   (a)   groundnut oil;

   (b)   cottonseed oil;

   (c)   sunflower seed oil;

   (d)   Soya beans oil; or

   (e)   A mixture of (a), (b), (c) and (d) above, in any proportion.

5. QUALITY REQUIREMENTS

5.1    General requirements

5.1.1 The oils and ingredients used shall be free from extraneous matter. Food additives as permitted, and not in excess of quantities stipulated under the current Food and Drugs Act, Cap. 303 of the Laws of Zambia and to Regulations made under the Act may be added to the product.

5.1.2 The oils shall be extracted, transported, stored, refined, processed and packed under sanitary and hygienic conditions complying with ZS 034.

5.1.3 The Product shall be free from objectionable matter as a good manufacturing practice.

5.1.4 The product shall be free from foreign and rancid adour and taste. The colour of the product shall be characteristic of the designated product.

5.1.5 The clarity of the material shall be judged by the absence of turbidity after keeping the filtered sample at 25°C for 24 hours.

5.2    Physical Requirements

When tested according to ZS 226: Part 2, the physical requirements of refined edible vegetable oils shall conform to those specified in table 1.

TABLE 1
PHYSICAL REQUIREMENTS FOR REFINED EDIBLE VEGETABLE OILS

<FT:Calibri,SN>Requirements

Characteristic

Groundnut

Soya beans

Sunflower

Cotton seed

Specific gravity

0.914-0.917

0.919-0.925

0.918-0.923

0.918-0.926

20/20°C

       

Refractive index

1.440-1.466

1.466-1.470

1.467-1.469

1.458-1.466

(Dna at 40°C)

       

Colour in 5.25 inch

       

Lovibond cell:

       

Red (max)

2

2

2

3

Yellow (max)

20

20

20

30

Moisture and volatile matter at 105°C% max

0.2

0.2

0.2

0.2

Insoluble impurities per cent max

0.05

0.05

0.05

0.05

Clarity at 25°C

       

After 24 hours

Clear, no sediment

Clear, no Sediments

Clear, no sediments

Clear, no sediments

5.3 CHEMICAL REQUIREMENTS

When tested according to ZS 226: Part 1, the chemical requirements of refined edible vegetable oils shall conform to those specified in Table 2.

TABLE 2
CHEMICAL REQUIREMENTS FOR REFINED EDIBLE VEGETABLE OILS

<FT:Calibri,SN>Requirements

Characteristic

Groundnut

Soya beans

Sunflower

Cotton seed

Acid valve, max

0.3

0.3

0.3

0.3

Iodine value

80-106

120-143

110-143

99-19

Saponification Value

187-197

189-195

188-189

189-196

Unsaponifiable matter, per cent max

       

Peroxide value, max

1.0

1.5

1.5

1.5

Soap content, per cent max

2.0

2.0

2.0

2.0

Aflatoxin level (B1)

0.005

0.005

0.005

0.005

PPb max

5

-

-

-

5.4 REFINED BLENDED EDIBLE VEGETABLE OIL.

When tested according to ZS 226: Part 1 and 2, the chemical and physical requirements of refined blended vegetable oils shall conform to those specified in Table 3.

6   PACKING AND MARKING

6.1 Packing

The product shall be packed in sound, clean bottles, new tins which are clean and free from rust, clean drums or other suitable material protecting the product without adversely affecting its quality composition, flavour and appearance. The cleaning and re-use of drums may be permitted provided an approved process is used.

TABLE 3
COMPOSITION AND QUALITY REQUIREMENTS FOR REFINED BLENDED EDIBLE VEGETABLE OILS.

Characteristics

Requirements

Method of Test refer to ZS 226

Acid value, max

0.3

Part 1

Peroxide value, max

2.0

Part 1

Moisture and volatile matter at 105°C, per cent max

0.2

Part 2

Insoluble impurities per cent max

0.05

Part 2

Soap content, per cent max

0.005

Part 1

<FT:Calibri,SN>6.2    MARKING

6.1.1    The following information shall be shown on the label:

   (a)   name of the product, with the brand name, if any;

   (b)   complete list of ingredients in descending order of proportion;

   (c)   net content by volume;

   (d)   the manufacturer’s name, address and trade mark, if any;

   (e)   code number of or batch number; and

   (f)   country of origin.

6.2.2 The packages may also be marked with the Zambian Bureau of Standards Certification Mark.

NOTE: The use of the Certification mark is governed by the Standards Act, Cap. 416 of the Laws of Zambia and the regulations made there under. This mark can only be used by the manufacturers licensed under the Certification mark Scheme operated by the Zambia Bureau of Standards (ZABS). Particulars of conditions under which licences are granted may be obtained from ZABS.

7. SAMPLING

Representative samples of the material shall be drawn as described in ZS 002.

8. TESTING

Tests shall be carried out as prescribed in ZS 226 Parts 1 and 2.

9. COMPLIANCE WITH THE STANDARD

The lot shall be deemed to comply with the quality requirement of the standard, if after testing, the test sample is found to comply with the relevant requirement of this Zambian Standard.

The lot shall also comply with the packing and marking requirements of clause 5.

ZAMBIA BUREAU OF STANDARDSZS

386: 2000

ZAMBIAN STANDARD

ZS 386: 2003

RUBBER CONDOMS (SINGLE USE) – SPECIFICATION

1. SCOPE

1.1 This specification covers rubber condoms intended for single use.

NOTE

   (a)   A requirement that must be specified by the purchaser is noted in Appendix A.

   (b)   Notes on storage are given in Appendix B

2. REFERENCE

The following standards and publication have been referred to this standard:

ISO 4074-5 Rubber condoms – Part 5 testing for holes

ISO 4074-6 Rubber condoms – Part 6 determination of bursting volume and pressure

ISO 4074-7 Rubber condoms – Part 7 determination of resistance to deterioration during storage

ISO 4074-9 Rubber condoms – Part 9 determination of tensile properties

ISO 4074-10 Rubber condoms – Part 10 packaging and labelling condoms in consumer packages

ISO/R188 Accelerated ageing of vulcanised rubber (air-oven method)

USA pharmacopoeia.

3. DEFINITIONS

For the purposes of this specification the following definitions shall apply:

<FT:Calibri,SN>Acceptable: to the parties’ concluding the purchase contract, but in relation to the certification mark and to inspections carried out by the Bureau, accepted to the Zambia Bureau of Standards.

<FT:Calibri,SN>Bubble pack: A form of airtight package in which a small amount of air is retained when the package is sealed so that the integrity may be checked by its bubble like feel.

<FT:Calibri,SN>Condom: A sheath or covering intended to be worn on the penis during coition for the purpose of preventing conception or reducing the risk of transmission of disease, or both.

<FT:Calibri,SN>Defective: A condom that fails, in one or more respects, to comply with the relevant requirements of the specification.

<FT:Calibri,SN>Lot: Not less than 3200 condoms in packages and bulk containers, bearing the same expiry date, the same type of closed end having the same type of surface (i.e. smooth or textured from one manufacturer, submitted at any one time for inspection and testing.

<FT:Calibri,SN>Spermicidal:A drug or other agent that kills spermatozoa.

<FT:Calibri,SN>Standard test conditions: A temperature of 23 ± 2°C relative humidity of 50 ± 4%.

4. REQUIREMENT

4.1 Materials

4.1.1 General

Condoms shall be manufactured from good quality natural rubber latex, and shall be free from, embedded grit and discoloration. The condoms and any dressing applied to them shall not liberate substances that are known to be toxic or otherwise harmful to the skin or mucous membrane, under normal conditions of use. A dressing material or compounding material shall not have a deleterious effect on the condoms.

4.1.2 Spermicidal-treated condoms

When so required by the purchaser, the condoms shall be treated with a finite amount of a spermicidal agent (see. 5.2.2. (h). The spermicides comply with the requirements for addressing (see 4.1.11) and shall be registered, as a spermicidal agent, with the Medical Council of Zambia.

4.2    DESIGN AND DIMENSIONS

4.2.1 Design

   (a)   Open end. The open end of a condom shall terminate in an integral bead that has a cross section diameter, determined in accordance with 7.3, of less than 0.8mm and not more than 1.7mm.

   (b)   Closed end. Shall be either with or without a teat.

4.2.2    Dimensions

   (a)   Length. The length of a condom (excluding, when relevant, the teat), determinate in accordance with 7.3, shall at least be 175 mm.

   (b)   Width. The width of a condom, when laid flat and measured at any point not more than 85mm below the rim of the bead either be (49 ± 2) mm or (53 ± 2) mm

   (c)   Thickness. The thickness of the double wall of a condom (i.e. its overall thickness when laid fat), measured in accordance with 7.3, shall be not less than 0.06mm and not more than 0.16mm.

4.3 MASS

The mass of the condom (free from dressing), determined in accordance with 7.4 shall not exceed 1.7g in the case of a smooth-surface condom and 1.9g in the case of condom with a textured surface.

4.4 BURSTING VOLUME AND PRESSURE

When tested in accordance with ISO 4074-6 or as described 7.10 the bursting volume shall be not be less than 18 dm3 and bursting pressure shall not be less than 1.0k pa. The compliance level shall be AQL of 15.

NOTE:

A defective condom is a condom that fails the requirements for volume, or the requirement for pressure, or both requirements i.e. condom failing both requirements is counted as one defective condom.

4.5 PHYSICAL PROPERTIES

The tensile strength, tested in accordance with ISO 4074-9, and elongation at break of condoms, determined in accordance with 7.5 shall comply with the following requirements:

   (a)   Sample tested less than 12 months after manufacture: Tensile strength Elongation at Mpa, min break per cent min.

      (i)    Without ageing 20 650

      (ii)    After accelerated ageing in accordance with 7.6 17 600

   (b)   Samples tested at least 12 months after manufacturer.

4.6 FREEDOM FROM HOLES AND VISIBLE DEFECTS

A condom shall be free from visible defects and from holes that are detected when it is in accordance with 7.7 or ISO 4074-5.

4.7 COLOUR

Unless otherwise required, the choice of colour shall rest with the manufacturer.

4.8 BLEEDING

When tested in accordance with 7.8 a condom shall cause no colour transfer to the absorbent paper.

4.9 PH VALUE OF AQUEOUS EXTRACT

When a condom is tested in accordance with 7.9 the ph value of the aqueous extracts shall be in the range 6 to 8.

4.10. ANALYSIS OF SPERMICIDAL AGENT

When a spermicidal – treated is required and is tested in accordance with 7.10 the analytically determined identification of the spermicide shall agree with the information as specified in 5.2.2 (g/and the measured quantity of spermicide shall be less than the amount as specified in 5.2.2h).

2. PACKING AND MARKING

5.1. Packing

Each condom shall be packed individually in a sealed, lightproof envelope of the bubble type that will protect packed condom from damage during normal storage and handling, in accordance with ISO 4074-7 and ISO 4074-10 and that can be torn open easily without causing any damage to the condoms (e.g. by the formation of sharp edges).

Only condoms that have the same expiry date type of closed end (i.e. with or without a teat (type of surface (i.e. smooth or textured) and type of dressing (i.e. with or without spermicidal agent) shall be packed together in anyone of the smallest multiple packages in which they are supplied and in larger bulk containers.

2. Marketing

2.2.1 Envelopes

The following information shall appear in legible and indelible marking on a =each envelope:

The manufacture’s name or trademark or both.

2.2.2 Smallest multiple packages

The following information shall be given in legible and indelible marking, on (or, in the case of instructions for use, in) each of the smallest multiple packages:

   (a)   the manufacture’s name and address and trade name or trade mark;

   (b)   the expiry date (month and year), which shall not be later than 5 years from the date of manufacture;

   (c)   the words USE EACH CONDOM ONCE ONLY”

   (d)   the words “STORE IN A COOL DRY PLACE”

   (e)   the type of closed end and the quantity of condoms

   (f)   Instructions for use

   (g)   The spermicidal agent’s chemical name

   (h)   The amount of spermicidal agent present in each condom (expressed in milligrams); and

      (i)   The ZABS Certification Mark

<FT:Calibri,SN>Note on the use of the certification mark

The Zambia Bureau of Standards is the owner of the registered certification mark shown below, the independent assurance that the product complies with the requirements of this Zambian Standard.

18ZS-

This certification mark may be used by manufactures only under licence from the Bureau. Particulars of the conditions under which licences are granted may be obtained from the Director, Zambia Bureau of Standards, P.O. Box 50259, Lusaka, 15101, Zambia.

5.2.3 Bulk containers. Each bulk container in which condoms or smaller multiple packages are supplied shall bear the following information in legible and indelible marking:

   (a)   the manufacture’s name and address and trade name or trade mark;

   (b)   a description of the contents;

   (c)   the expiry date (month and year)

   (d)   the quantity of condoms; and

   (e)   the words “STORE IN A COOL DRY PLACE”

6. SAMPLING AND COMPLIANCE WITH SPECIFICATION

NOTE

This section applies to the sampling for inspection and testing before acceptance or rejection of single lots (consignments) in case where information about the implementation of quality or control or testing during manufacture is available to help in assessing the quality of the lot. It is also used as the procedure for adjudicating in cases of dispute.

6.1 Sampling

The following sampling produce shall be applied in determining whether a lot complies with the relevant requirements of the specification. The samples so drawn shall be deemed to represent the lot for the respective properties.

6.1.1 Sampling for inspection and testing for holes. After checking for compliance with 5.2. drawn at random from the lot, the number of condoms shown in column 2 of Table 1 relative to the appropriate lot size shown in column 1.

6.1.2 Samples for remaining tests. For each of the following remaining tests drawn at random, from the lot 10, condoms:

   (a)   dimensions and mass;

   (b)   tendril properties;

   (c)   bleeding;

   (d)   ph value of aqueous extract

TABLE 1
–Sample sizes and acceptance numbers

Lot size

Sample for inspection and testing freedom from holes

 

Sample size condoms

Acceptance number defectives

3200-10000

200

0

10001-35000

315

0

35001-150

500

0

15001-50000

800

0

Over 50000

1250

0

*Application to holes and tears only

3.2 Compliance with the specification

The lot shall be deemed to comply with the requirements of the specification if, on inspection and testing of the sample taken in accordance with 6.1:

   (a)   the total number of defectives found with tears or holes does not exceed the appropriate acceptance number given in column 3 of Table 1; and

   (b)    no defect is found in respect of any other property.

7. INSPECTION AND METHODS OF TEST

7.1 Conditioning

Unless otherwise specified in the method, condition all test specimens for at least 16 hours the standard test conditions (see 3.1) before testing them and conduct the test under these conditions.

7.2 Inspection

Inspect each condom in the sample taken in accordance with 6.1.1 for compliance with the requirements for marking (see 5.2) and for freedom from visible defects (see 4.6). Retain all condoms that are free from visible holes and tests for test given in 7.7.

7.3 Dimensions

7.3.1 Apparatus

   (a)   Calibrated rod. A rod diameter 20mm, having a hemispherical end and graduated in millimetres.

   (b)   steel rule, graduated in millimetres.

   (c)   Thickness gauge. A calibrated thickness gauge capable of determining a difference in thickness of 0.002 mm and having flat tips diameter approximately 5mm that exert in use a pressure of 20 ± 3kpa.

7.3.2 Test specimens. The 10 condoms in the sample drawn in accordance with 6.1.2.

7.3.3 Procedure

   (a)   Length. Uses the calibrated rod to measure the length (excluding, when relevant, the teat of a condom by inserting the hemispherical end of the rod into the condom.

   (b)   Width. Use the rule to check for compliance with 4.2.2 (b).

   (c)   Thickness of wall and diameter of bead. In the case of lubricated or powdered condoms remove the dressing by means of propan-2°1, then use the thickness gauge to measure on each specimen, the thickness of the double wall at a point approximately 80mm below the bead and the cross-section diameter of the bead.

7.4 Mass

<FT:Calibri,SN>7.4.1 Apparatus. A balance capable of determining mass to an accuracy 0.01g(or better).

7.4.2 Preparation of test specimens. Use the specimens that were used in the test given in 7.3 and in the case of condoms that were treated with propan -2°1, dry them to constant mass at temperature exceeding 37°C.

7.4.3 Procedure. Determine, to the nearest 0.01g the mass of each specimen.

7.5 TENSILE STRENGTH AND ELONGATION AT BREAK

7.5.1 Apparatus

The apparatus shall consist of:

   (a)   a cutting die consisting of two parallel knives (each having a cutting edge of length of at least 70mm) set 20mm apart in a press: and

   (b)   a tensile testing machine with a rate of travel of the moving jaw of 500mm/min and having, instead of normal clamps, 2 rollers each of diameter 15mm, one free to revolve on a bearing and the other rotated at a constant speed of about 7r/min.

7.5.2 Preparation of test specimens. After, in the case of condoms tested within 12 months of manufacture ageing 5 of the condoms in the sample (see 6.1.2(b) in accordance with 7.6, remove any dressing from the 10 condoms with propan –2ol.

Then, immediately immerse them in a suspension of talcum powder (of particle size not exceeding 1-m) in propan 2-01 and allow them to dry by hanging them open end upwards. From each of the condoms in the sample cut a test specimen as follows.

Lay the condom flat with its length at right angles to the cutting edges of the die, and from a smooth portion and with one stroke of the press, cut a specimen (in the form of a ring) from a region about 80mm away from the bead.

NOTE

To minimise errors in testing, take care to ensure that the ring specimen is cut at the right angles to the length of the condom. Discard and replace any specimen that has not been completely separated at the first attempt.

7.5.3 Procedure. Determine the mean single wall thickness of each test specimen then lay it flat and measure the distance between the two folded edges. Record twice this distance as the perimeter, P, of the specimen.

Place the ring over the roller of the tensile machine and stretch it until it breaks.

Record the maximum force registered before and the separation distance (between centres of the rollers) at break.

7.5.4 Calculations

   (a)   Calculate the strength and elongation at break of each specimen as follows:

Tensile strength, MPA=F/2wt

where F=the breaking load. N

w= the width of the test specimen, i.e. 20mm

t= the single wall thickness, mm

Elongation at break per cent K + 2D – P x 100/ P

Where K = length of test in specimen in contract with the rollers, mm (47mm with 15 mm diameter rollers).

P = original perimeter of specimen, mm

D = final distance between rollers, mm

   (b)   Disregarded the highest and lowest result obtained for each set of 5 or 10 (as relevant) specimens, and record then mean values of the remaining results as the tensile strength and elongation at break of the set.

7.6 AGING

Age the five condoms (in their envelopes) in accordance with ISO/R 188 but for only 12 hours, and then allow them to cool for at least 12 hours.

7.7 FREEDOM FROM HOLES

7.7.1 Apparatus

The apparatus shall consist of:

   (a)   a mount, which is suitable equipment for suspending a condom by its open end allowing it to be filled (after mounting) with water;

   (b)   platform, placed about 200mm below the mount to support a filled condom; and

   (c)   dry absorbent paper preferably coloured)

7.7.2 Test specimen. The test specimen shall be the condom retained in terms of 7.2.

7.7.3 Procedure. After, when applicable, rolling the condoms over a separate sheet of absorbent paper to remove surplus lubricant applied during manufacture, fit the open end of the condom under test on the mount, secure it (by means of the rubber ring) and pour into it 300ml of water at room temperature.

After about 1 minute inspect for leakage through the wall. If there is no sign of leakage, carefully remove the condom from the mount, and close the open end tightly by twisting the walls near the bead. Roll the water filled condom firmly at least twice over a sheet of the dry absorbent paper and inspect the paper for signs of leakage. Record a condom that shows any sign of leakage (in either stage of the test) as defective.

7.8 BLEEDING

7.8.2 Equipment. Dry, white absorbent paper.

7.8.3 Test specimens. The 10 condoms in the sample drawn in accordance with 6.1.2(c).

7.8.3 Procedure. Thoroughly wet each specimen (inside and out) with tap water but no attempt to remove any dressing material. Wrap each wet specimen (separately) in a piece of the absorbent paper that the largest possible surface area of the specimen is in contact with the paper, and place the assembly in a suitable air tight container that will prevent loss of moisture. After 16 hours remove from the container and remove absorbent paper and examine it visually, in natural daylight, for any indication of colour transfer.

7.9 DETERMINATION OF PH VALUE OF AQUEOUS EXTRACT

7.9.2 Apparatus. A ph metre.

7.9.3. Test specimens. The 10 condoms in the sample drawn in accordance with 6.1.2 (d).

7.9.4 Procedure. Immerse each specimen (separately) in 100 ml of distilled water for 48 hours, and then determine ph value of each extract.

7.10 ANALYSIS OF SPERMICIDAL AGENT

The identification of the spermicidal and its measured quantity shall be determined using the appropriate method described in the current edition of the US Pharmacopoeia.

7.11 DETERMINATION OF BURSTING VOLUME AND PRESSURE

7.11.1 Apparatus. Inflation apparatus, suitable for inflating the condom with clean, oil-free and moisture-free air at a specified rate, provide with equipment for measuring volume and pressure having the following feature:

   (a)   a pressure sensor configured such that there is no pressure differential between the condom and the pressure sensor;

   (b)   an apparatus for recording the volume of inflation air, configured such that there is no pressure differential between the measuring device and the condom, thereby ensuring that the volume of air is measured at the appropriate pressure within the condom and not at the line pressure which may be higher;

   (c)   a rod of suitable length having smooth sphere or hemisphere 25mm in diameter at its top hanging the unrolled condom when the condom is clamped the length of condom, excluding there reservoir remaining for inflation is (150 ± 3) mm.

   (d)   Pressure and volume measuring equipment capable of:

      (i)   a maximum permissible limit of error = 3% for volumes greater than 101, whatever method issued to measure volume;

      (ii)    measuring the pressure at bursting of the condom with a maximum permissible limit of error of 0.05kpa.

   (e)   a clamping device and clamping ring, having no sharp edges or protrusions and being of the recommended integral diameter 38 mm, recommended height 50 mm and the recommended material of constructional being transparent plastic; and

   (f)   an inflation cabinet having a facility for viewing the condom during inflation, and being of sufficient size to allow the condom to expand freely without touching any part of the cabinet.

7.11.2 Procedure. Carry out the test under controlled conditions of (25 ± 5 )°C and (50 ± 60)% relative humidity.

Move the condom inside the package is such that it is away from the area where the package is to be torn. Tear the package and remove the condom.

The person testing shall not in any circumstances use scissors or other sharp instruments to open the package. Unroll the condom ensuring that it is not excessively stretched in any direction.

NOTE

The condom may be unrolled directly onto the rod of the test equipment. Hang the condom on the rod and affix to the mount. Take care when placing the clamping ring on its mount to avoid damaging or stretching the condom. Inflate with air at rate of (0.4 to 0.5) dm3/s (24 to 30) dm3/min) figures check to ensure that the condom expands and that there are no obvious leaks.

If the condom exhibits any obvious leaks, or are detected during the inflation discontinue the test. The condom shall then be recorded as defective and bursting volume and pressure recorded as zero.

If the condom does not leak, measure and not the bursting volume in cubic decimeters rounded to the 1.0dm3and the bursting pressure, in kilopascals rounded to the nearest figure 1.0kpa.

APPENDIX A

NOTES TO PURCHASERS

The following requirement must be specified in tender invitations and in each order or contract:

   (a)   the type of closed end, i.e. with or without teat[(see 4.2.1 (b)]

   (b)   when relevant, the colour (see 4.70);

   (c)   when relevant, the type of spermicidal agent (see 4.12);

   (d)   when relevant, the type of dressing i.e. with or without a spermicidal agent (see 4.2 and 5.2.2(g) and (h).

APPENDIX B

NOTES ON STORAGE

Condon that comply with the requirements of the specification are packaged in a way that will protect them during normal storage and handling. However, such articles are diversely affected by heat and light should be stored in a cool place away from direct sunlight and from sources of direct heat such as boilers, steam pipes, heaters, etc, and protected from contact with petroleum – based products.

The information in the Appendices is additional to that in the specification and has been included purely for information and guidance.

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS 056: 2003

TOILET SOAP – SPECIFICATION

1. SCOPE

This Zambian Standard specifies the requirements and corresponding test method for toilet soap.

2. TERMINOLOGY

For the purpose of this Standard the following definitions apply:

2.1 Free caustic alkali

The free (uncombined) caustic alkali present in soap.

2.2 Matter insoluble in alcohol

Comprise most of alkaline salts, such as talc, carbonates, borates, silicates and phosphates as well as sulphate starch, which are insoluble in alcohol under the conditions of the test.

2.3 Free fatty acids

The free (uncombined) fatty acids present in soap and is expressed as per cent by mass, oleic acid.

2.4 Total fatty matter

It includes substances, soluble under the conditions of test 15 of ZS060: Methods of Sampling and Testing for Soaps, such as fatty and rosin acids present in a combined state as well as unsaponified and unsapoinfied matter.

2.5 Unsaponified matter

The neutral fat (unsaponified neutral glyceride) present in soap.

3. REQUIREMENTS

3.1 The soap shall be in table form and shall be of firm texture, thoroughly unsaponified and free from objectionable odour and shall possess good cleaning and lathering properties.

3.2 Toilet soap may contain perfume, colouring matter, preservatives, medicaments and supper fatty agents and such additional substances as are declared on the label. All the foregoing ingredients shall be non-injurious.

3.3 Toilet soap shall contain also the requirements specified in the table set out in appendix.

3.1.1 Calculation of results, toilet-liable to lose some moisture on keeping. The result of analysis in respect of items 1.4 and 6 of the table shall be recalculated in relation to the specified minimum fatty matter (see table item 8) by means of equation:

Recalculated results = Actual result x specified minimum total fatty matter content/Actual total fatty matter

4. PACKAGING AND LABELLING:

4.1 Packaging

The toilet soap table shall be wrapped in clean, undamaged wrappers or cartons.

The packing material shall be impregnated with antifungal agents.

4.2 Labelling

The packages shall be securely wrapped and marked with the following:

   (a)   the type of soap, brand name of the product and trade mark, if any;

   (b)   net content by mass;

   (c)   name and address of manufacture;

   (d)   boil No. or lot No. in code or otherwise, and date of manufacture; and

   (e)   the packages may also be marked with the ZS Certification Mark

NOTE

The ZS Certification Mark may be used by manufacturers; and from the Zambia Bureau of Standard (ZABS) particulars of conditions under the licences are granted may be obtained from ZABS.

19ZS

5. SAMPLING

5.1 For the purpose general precautions, scale of sampling and preparation of test samples, shall be as prescribed in ZS 060.

5.1.1    The determination of total fatty matter, free caustic alkali and unsaponified fatty matter shall be conducted on each on the individual samples separately.

5.1.2    The determination of all the remaining characteristics shall be conducted on the composite sample.

6. CRITERIA FOR CONFORMITY

6.1 For individual samples

For each of the characteristics, which have been, determine on the individual on the samples (5.1.1) they mean (x) and the range ® of the test results shall be calculated.

The lot shall be deemed as conforming to the expression (x) –0.6r) is greater than an equal to the minimum value given in the table and (x + 0.6) is less than or equal to the maximum value given in the table.

6.2 FOR COMPOSITE SAMPLE

For declaring the conformity of the lot to the requirements of other characteristics determined on the composite sample, the test results of each of the characteristics shall satisfy the relevant requirements in the table.

APPENDIX

TABLE
REQUIREMENTS AND TEST METHODS

SL. No.

Property

Requirement

Test Method as to ZS060

1.

Matter insoluble in alcohol (ethanol) per cent by mass maximum

1.0

4

2

Moisture and volatile matter percent by mass maximum

1.5

5

3

Matter insoluble in water percent by mass maximum

1.0

6

4

Free caustic alkali content, as sodium oxide (Na2O) percent by mass,

0.05

7

5

Chloride content as sodium chloride percent by mass, maximum

0.75

10

6

Unsaponified fatty matter, percent by mass maximum

0.1

13

7

Rosin acids content percent, by mass of total fatty matter maximum

3.0

14

8

Total fatty matter percent by mass, minimum

78.0

15

ZAMBIA BUREAU OF STANDARDS

ZAMBIAN STANDARD

ZS 435:2003

WHEAT FLOUR – SPECIFICATION

1. SCOPE

1.1.1 This standard prescribes requirements and methods of test for wheat flour for human consumption prepared from common wheat, triticum aestivum L.

1.2 This standard applies to whole-wheat flour, flour for bread, cakes and other bakery products.

2. DEFINITION OF PRODUCT

2.1 Wheat flour is the product prepared from grain of common wheat triticum aestivum 1, by grading or milling processes in which the bran and germ are partly removed and the remainder is comminuted to a suitable degree of fineness.

2.2 White bread flour (bakers flour) is a product, which is a pure sound yellowish sieve.

2.3 Cake flour is a product, which is a pure, sounds whitish wheaten flour and at least 95% of the product capable of passing through 212-micron wire mesh sieve.

2.4 Brown bread flour (Chapati flour) is a product, which is pure sound brownish wheaten flour and shall contain 11% bran when sieved through a 212-micron wire sieve.

2.5 Whole Wheat flour is a pure sound brownish wheaten meal.

2.6 Self-raising flouris the product made from a mixture of wheat flour, sodium bicarbonate and acid ingredients so that when made into a dough and baked, carbon dioxide is generated, which causes dough separation and development.

3. ESSENTIAL COMPOSITION AND QUALITY FACTORS

3.1 The wheat from which the flour is milled shall be of sound and marketable quantity, free from abnormal smell, pests and sand particles. It shall not contain impurities in excess of the following:

   (a)   matter other than basic cereals of unimpaired quality, of which: shrivelled grains, grains of other cereals, weeds, husks ergo, decayed grains, dead insects fragments of insects, 2% (m/m): and

   (b)   grains damaged by pests, discoloured grains and sprouted grain 1% (m/m).

3.2 Flour shall conform to the compositional requirements in the table set out in the Appendix.

3.3 Self raising flour. The ingredients sodium bicarbonate and acid calcium phosphate shall be added in such amounts that the available carbon dioxide shall not be less than 0.4% (m/m).

3.4 Food additives. The additional to flour of food additives such as vitamins improvers and minerals shall be such as not be a health hazard to the consumers and be in conformity with the legislation in operation in the country.

3.5 QUALITY FACTORS

3.5.1 The flour and any added ingredients shall be clean, safe, suitable and of good quality.

3.5.2 All processing of the wheat, including, drying, milling and other treatment of the wheat, intermediate milling products and milled flour shall be carried out in a manner that:

   (a)   minimises loss of nutritive value, particularly protein quality; and

   (b)   avoids undesirable changes in technological properties of the flour.

3.5.3 After milling and before packing and dispatch the flour shall be treated to destroy any insects or mites infestation, which might be present.

4. CONTAMINANTS

4.1 Wheat flour shall be free from heavy metals in amount, which may represent a hazard to health.

4.2 The flour shall be free from pharmacological active substances such as toxins derived from poisonous weeds, seeds or ergot.

4.3 The flour shall be manufactured in accordance with good manufacturing practices so as to eliminate or reduce as far as possible pesticide residues the use of which may be necessary during the production, storage or processing of the flour, or in the disinfection of the premises and materials used for the processing.

4.4 The amount of aflatoxins present if any shall not exceed 0.0125mg/kg.

5. HYGIENE

5.1 In order to conform with good manufacturing practice, the flour shall be free from objectionable matter. The premises in which milling is carried out shall be protected, as far as possible, against all infestation, insects mite and rodents.

5.2 The flour shall be free from pathogenic organisms. It shall be free from any substances originating from microorganism, which may represent hazard to health.

5.3 The product covered by the provisions of this standard shall be prepared in accordance with ZS 034: General Principles of Food Hygiene.

6. PACKAGING

6.1 The flour shall be packaged, transported and stored in containers, which will safe guard the hygienic, nutritional and technological qualities of the product.

6.2.    The packaging material shall be clean, strong, dry and impervious.

6.2.1 The packaging material shall not transfer to the flour any toxic substances, undesirable odour or taste.

6.3 Marks used of printing shall be non-toxic ink or paint. Under no conditions shall these marks be in contact with the product.

7. LABELLING

7.1. In addition to the provisions of the Zambia Standard ZS: 33 – General Guideline for labelling of prepacked foods the following specific provisions shall apply:

7.1.1 Containers shall bear the name and grade of the material, which shall be deemed to conform in essential composition to the requirement of section 3.2.

7.1.2 The label shall give any enrichment added.

7.1.3 The wording “store in a cool dry place” shall appear on the container in a conspicuous and appropriate place.

7.1.4 The statement “human food” shall appear on the bags.

7.1.5 The net mass shall be declared according to the metric systems ST (System international) units.

7.1.6 The name and address of the manufacturer or packer shall be declared.

7.1.7 The date of packing and date of minimum durability (preceded by the words best before) shall be declared by the day, month and year in uncode numerical sequence except that for products with a shelf life of more than three months, the month and year will suffice.

8. METHODS OF SAMPLING AND ANALYSIS

8.1 Sampling. The sampling procedure will be in accordance with the method recommended by the International Organisation for Standardisation (SI) ISO 2170-1980(e) – Cereals and pulses –sampling of milled products.

8.2 DETERMINATION OF GRANULARITY

8.2.1 Apparatus

Sieve shaker and nested set off sieves and pans about 20cm diameter numbers 20, 30, 40, 60, 100 or other similar sieves.

8.2.2 Procedure

Weigh accurately about 50 ± 0.1g of well-mixed, representative sample of grits (to obtain representative sample 100g pass successively through sample divider). Transfer sample to top sieve of set of sieves with pan. Assembled and fixed in shaker, and shake for 5 minutes. Weigh to 0.1 g grits particles remaining on and adhering to each of sieves, or caught in pan.

Calculate weight of each sieve fraction as percentage of sample weight.

Report percentage of each fraction to 1 decimal place.

8.3.  Determination of fibre contents

8.3.1 Reagents

Alcohol-industrial methylated spirit.

Diethyl ether.

Hydrochloric acid, 1 percent v/v dilute 10ml concentrated hydrochloric acid with water to 1 litre.

Light petroleum- boiling point 40-60°C.

Sodium hydroxide, 0.313M – The solution must be free or nearly free from sodium carbonate.

Sulphuric acid 0.1275 M.

8.3.2 Procedure

Weigh sample 2-3g of flour.

Transfer to a dry 600mi beaker, avoiding fibre contamination from paper or brush. Add 200ml boiling 0,127Mh 2SO4 and one-drop dilute antifoam (Excess antifoam may give high results; are used only if necessary to control foaming). Bumping chips or granules may also be added. Place the beaker on digestion apparatus with preadjusted hot plate and boil exactly 30 minutes, rotating the beaker periodically to keep solids from adhering to sides. Remove beaker and filter as follows:

Prepare a Hartley form of Buchner funeral fitted with a perforated plate by adjusting a piece of cut cotton cloth of filter paper to cover the holes in the place so as to serve as a support for a circular piece of suitable filter paper.

Filter contents of the beaker through Buchner funeral rinse the beaker with 50-70m boiling water and wash through butcher funnel. Repeat with three 50ml portions of water, and suck dry.

Remove the filter and residue by snapping bottom of Buchner against the top while covering the stem with thumb of forefinger and replace in the beaker. Add 200ml boiling 0.31ml boiling, 0.313 MNOaOH and boil exactly 30 minutes.

Remove the beaker and filter as above. Wash with 25ml boiling 0.127 MH2so4 three 50ml portions of water and 25ml alcohol. Remove filter and residue: transfer to aching dish.

<FT:Calibri,SN>Treatment of residue

Dry the filter paper and residue for hours at 130 ± 20°C. Cool in desiccator and weigh incinerate the weighed ashles paper and contents to an ash as a dull red heat. Cool in a cool desiccators and reweigh.

per cent Crude fibre in sample =C= (loss in weight on ignition – loss in weight in incinerator) x 100/wt sample.

8.4 Determination of fat acidity

8.4.1 Reagent

   (a)   Benzene alcohol phenolphthalein solution – 0.20%.

To one litre benzene add one litre alcohol and 0.4g phenolphthalein.

   (b)   Alcohol phenolphthalein solution 0,04% to one litre alcohol add 0,4g phenolphthalein.

   (c)   Potassium hydroxide standard solution – 0,0178N, carbonate free I ml = 1mg/koh.

8.4.2 Apparatus

   (a)   Fat extraction device-soxhlet other suitable type.

8.4.3 Procedure

Extract 10 ± 0,01g ground sample with petroleum ether. Ca 16 hr in extractor. Start extraction as soon as possible after grinding and never let ground sample remain overnight. Completely evaporate solvent from extraction on steam bath. Dissolve residue in extraction flask with 50ml benzene-alcohol phenolphthalein in solution and titrate with standard KOH solution to distinct pink or in case of yellow solution to orange-pink or in case of yellow solution to orange-pink. If emulsion forms during titration, dispel by adding second 50ml portion of benzene-alcohol phenolphthalein solution. End point should match colour of solution made by adding 2.5ml 0,01%Knno4 Solution to 50ml K2Cro7 solution of proper strength to match colour of original solution being titrated, (Add 05, %K2CR207 solution drowse to 50ml H20 until colour matches. Then add 2,5ml 0,01 KmnO4 solution.

Make blank titration of 50ml benzene – alcohol phenolphthalein solution and subtract this value from titration values of sample. If addition 50ml potion benzene-alcohol phenolphthalein solution was added, double blank titration. Report fat acidity as mg KOH required to neutralise free fatty acids from 100g grain (dry basis). Fat acidity = 10 x (titration-blank).

8.5 Determination of moisture content

Use ISO 712-1979 (E)-cereals and Cereal products-Determination of content (Routine Method).

8.6 Determination of ash

Use ISO 2171-1981 (E)-cereals pulses and deprived product – Determination of ash.

8.7 Determination of fat

Use the method in the Association of Official Analytical Chemists (AOAC 14:067 and 7056).

8.8. Determination of Protein

Use ISO 1871-1979(E) –Agricultural Food Products – General Directions for the Determination of nitrogen by the Kjeldahl Method.

8.9    Determination of flour colour as affected by grade

8.9.1    Apparatus

- Kent – Joes and Martin flour colour gander

- Measuring cylinder

-Beaker

-Glass rod

-Stop watch or stop clock

8.9.2    Method

   (a)   Switch on the instruments for about half an allow it to warm up with the cell holder in the raised position and the main dial set so that curser line (blank) is immediately over the read line. Move the galvanometer spot coincide. Operate the tapping key and rotate the adjust Zero until the galvanometer sport does not move from its zero position showing that both photo cells are receiving the same amount of light.

   (b)   Prepare a flour paste by mixing together in a beaker 30g of flour and 10ml of distilled water. Mix the flour with a glass rod into a paste for 45 seconds and pour into the clean glass cell, the later being held at an angle so that the working face is down wards thus obviating difficulties from air bubbles on reflecting surface.

   (c)   Insert the sample cell into the upper half of the cell holder of the instrument operate the galvanometer key and then adjust zero control to check that the instrument is still balanced. Then carefully depress the cell holder into the down position. Operate the galvanometer key and rotate the main dial again until the galvanometer spot does not move. Read the grade figure directly of the scale of the instrument.

   (d)   Raise the holder cell holder and remove the sample cell, reset the main dial line value. The instrument is then for the next test.

<FT:Calibri,SN>Precaution

Make sure that the time of the test from the commencement of the mixing of the flour paste to the actual reading of the result is between 90-120 seconds.

If the time is less than 90 seconds, it will usually be found that the grade figure recorded is on the low side while if a longer time is taken over the test, the grade value found will be on the high side.

ZS 435:2003

APPENDIX

TABLE
COMPOSITIONAL REQUIREMENTS OF FLOUR

Class of product

Moisture content max% (m/m)

Ash content max per cent (m/m)

Fat content Max per cent (m/m)

Fibre content max. per cent (m/m)

Protein content %(m/m)

Colour grade

Wheat Bread flour (bakers colour)

13

0.8

0.2

0.3

10.0min

6.5max and 2.5

Cake flour Brown bread flour

13.0

0.5

0.2

0.3

8.0 max

2.5max

Whole wheat

13.0

1.0

0.2

2.5

10.0 min

13.5 max

Flour

13.0

1.5

2.0

2.5

10.0 min

N/A not Accountable

Self-raising flour

13.0

0.8

2.0

0.3

10.0

 

 

SECOND SCHEDULE

[Paragraph 3]

Name of Commodities

Beer

Biscuits

Cattle feeds

Compound Fertilisers

Household and dishwashing liquid detergent

Lead-acid starter batteries

Pig Feeds

Poultry Feeds

Refined edible vegetable oil

Rubber condoms (single use)

Toilet soap

Wheat flour.

 

STANDARD (COMPULSORY STANDARDS) (DECLARATION) ORDER, 2011

[Section 7]

Arrangement of Paragraphs

Paragraph

   1. Title

   2. Declaration of compulsory standards

   3. Application of standards

      FIRST SCHEDULE

      SECOND SCHEDULE

SI 32 of 2011.

 

1. Title

This Order may be cited as the Standards (Compulsory Standards) (Declaration) Order, 2011.

 

2. Declaration of compulsory standards

The Standards set out in the First Schedule are hereby declared as compulsory standards.

 

3. Application of standards

The Standards set out in the First Schedule shall apply to the respective commodities listed in the Second Schedule.

 

FIRST SCHEDULE

[Paragraph 2]

COMPULSORY STANDARDS

ZAMBIA BUREAU OF STANDARDS

ZS 547 Part I:2011

LUBRICATING OILS – SPECIFICATION

 

PART I
AUTOMOTIVE GEAR OILS

1. Scope

1.1   This Zambian Standard specifies requirements for automotive and manual transmissions, transaxles and axles operating under a variety of conditions of speed, load and gear types.

1.2   The automotive gear oil acceptance criteria, in terms of quality and performance level, shall be primarily based on the AP1 service designation. These are based on the type of service in which the gear oil will be used.

2.  Note

   AGMA   American Gear Manufacturer’s Association

API      American Petroleum Institute

ASTM   American Society for Testing and Materials

CP      centi Poise

COC   Cleveland Open Cup

CSt    centi Stokes

SAE   Society of Automotive Engineers

ZS      Zambian Standards

3. Normative reference

In this Standard, reference has been made to the following standards:

ASTM D92/IP 36      Test method for flash and fire points by Cleveland Open Cup (COC)

ASTM D130/IP 154   Test method for detection of copper corrosion from petroleum products by the copper strip test.

ASTM D2270/IP 226   Standard practice for calculating viscosity index from kinematic viscosity at 40ºc and 100 ºc.

ASTD 2983   Test method for low-temperature viscosity of automatic fluid lubricants measured by the Brook Field Viscometer.

ASTM D97/IP 15    Pour point method

ZS 317   Road tank vehicles for petroleum based flammable liquids-specification.

ZS 385   The Petroleum Industry: Part 1 – Storage and distribution of petroleum products in above ground bulk installations –Code of Practice.

ZS 396    Sampling petroleum products: Part 1 – manual sampling of liquid hydrocarbons.

4. Definitions

For the purpose of this Standard, the following definitions apply:

4.1   Additive

A compound added to engine oil to enhance properties and performance.

4.2   ASTM method

The test method published by the American Society for Testing and Materials, in the United States of America.

4.3   ASTM reference sequence

The reference test sequence given in STP 315H, published by the American Society for Testing and Materials in the United States of America.

4.4   Automotive

Equipment associated with self-propelled machinery usually vehicles driven by internal combustion engines.

4.5   Base oils

Refined additive-free oils of varying viscosity grades, which are used in the manufacture of formulated lubricants.

4.6   Category

A designation such as API GL-1 or API GL-5 for a given level of performance in specific filed tests.

4.7   Classifications

The systematic arrangement into categories according to different levels of performance in specified field tests.

4.8   Gear oil

A liquid that reduces friction and wear between the moving parts within a power transmission system, serves as a coolant and may contains additives to enhance its performance and inhibit rusting, oxidation and foaming.

4.9   IP Method

The test method published by the Institute of Petroleum in the United Kingdom.

4.10   SAE service classification

The internal combustion engine service classification as defined in SAE JI83, published by the Society of Automotive Engineers in the United States of America.

5.  Requirements

5.1 General

5.1.1   The API service categories based on an open-ended alphanumeric gear lubricant designations (API GL1, API GL2, API GL3, API GL4 and API GL5) shall apply.

5.1.2   A marketer of automotive gear oil marketed in Zambia shall ensure that the automobile gear oil has a product data sheet which, apart from other proprietary information, shows all the details listed in Table 1 and 2 together with the corresponding properties.

6.  Packaging and marking

6.1 Packaging

The condition of selling or transporting oil containers shall be such as not to be detrimental to the quality of the oil during normal storage or transportation and shall comply with the provisions and requirements of the following standards:

ZS 371    Road tank vehicles for petroleum based flammable liquids – specification.

ZS 385    The Petroleum Industry: Part I storage and distribution of petroleum products in above ground installations – Code of Practice.

Marking

The following information shall appear in legible and indelible marking on an automotive gear oil containers apart from other proprietary information:

   (a)    product brand name;

   (b)    manufacturer’s name;

   (c)    SAE Viscosity grade;

   (d)    API service category;

   (e)    Intended application;

   (f)    Quantity contained in litres or kilogrammes as applicable; and

   (g)    Safety, health and environmental information.

7.  Sampling

   Sampling shall be done in accordance with the provisions given in ZS 396 and ASTM D4057.

Table 1: Requirements for automotive API GL-4 gear oils

SAE Viscosity Grade

SAE Grade

75W

80W

75W/90

80W/90

90

85W/140

140

Product Identity

Not applicable

Brand

Brand Name

Brand Name

Brand Name

Brand Name

Brand Name

Brand Name

Viscosity at 100ºC

ASTM D445/I71

4.1 Min

7.0 Min

13.5 Min

13.5 Min

13.5-24.0

13.5-24.0

24.0-41.0

Viscosity

ASTM

90 Min

90 Min

90 Min

90 Min

90 Min

90 Min

90 Min

Flash Point (COC),

ASTM D92/IP36

144 Min

190 Min

178 Min

200 Min

200 Min

200 Min

200 Min

Pour Point (ºC)

ASTM D97/IP 15

-24

-24

-24

-24

-24

-24

-24

Copper Corrosion

ASTM D130/IP

2C Max

2C Max

2C Max

2C Max

2C Max

2C Max

2C Max

Table 2: Requirements for automatic API GL-5 gear oils

TEST

TEST METHOD

REQUIREMENTS

SAE Viscosity Grade

SAE GRADE

75W

80W

75W/90

80W/90

90

85W/140

140

Product Identity

Not applicable

Brand name

Brand Name

Brand Name

Brand Name

Brand Name

Brand Name

Brand Name

Viscosity at

ASTM D445/I71

4.1 Min

7.0 Min

13.5 Min

13.5 Min

13.5-24.0

24.0

24.0-41.0

Viscosity Index

ASTM D2270/IP226

90 Min

90 Min

90 Min

90 Min

90 Min

90 Min

90 Min

Flash Point (COC), ºC

ASTM D92/IP36

200 Min

200 Min

200 Min

200 Min

184 Min

200 Min

200 Min

Pour Point (ºC)

ASTM D97/IP 15

-21

-21

-21

-21

-21

-21

-21

Viscosity of 150,000

ASTM D2983

-40

-26

-40

-26

-

-26

-

Copper Corrosion

ASTM D130/IP 154

2C Max

2C

2C

2C

2C

2C

2C

ZAMBIA BUREAU OF STANDARDS

ZS 547 Part 2: 2011

LUBRICATING OILS – SPECIFICATION

 

PART II
INDUSTRIAL GEAR OILS FOR OPEN GEARS

1.  Scope

1.1   This Zambian Standard specifies requirements for open gear lubricants to be used for various methods of application to the general industrial helical, herringbone, spur and bevel open gears.

1.2   The open gear lubricants acceptance criteria shall primarily be based on the performance criteria stipulated by the American Gear Manufacturers Association. Reference will also be made to other institutions such as the International Organisation for Standard and the American Society for Testing and Material.

1.3   The industrial gear oil shall be a mineral oil blended with additives to provide the requisite level of oxidation and thermal stability, rust and wear protection, demulsibility and foam inhibition for application intended.

1.4   This Zambian Standard applies only to semi enclosed and open gearing systems, where associated bearings are lubricated separately.

2.  Note

<BC:0,0,0,DC>AGMA American Gear Manufacturer’s Association
API American Petroleum Institute
ASTM American Society for Testing and Materials
COC Cleveland Open Cup
SAE    Society of Automotive Engineers
CSt centi Stokes
CP centi Poise
EP Extreme Pressure
ISO International Organisation for Standardisation
ISO VG International Organisation for Standardisation
Viscosity grade
PMCC Pensky Martens Closed Cup

3. Normative reference

In this Standard, reference has been made to the following standards:

<BC:0,0,0,DC> ASTM D88

Test method for flash and fire points by Cleveland Open Cup (COC).

ASSSTM D92/IP 36

Test method for flash and fire points by cleverland Open Cup (COC).

ASTM D93/IP 34

Test method for flash point of petroleum products by Pensky – Martens closed cup (PMCC).

ASTM D130/IP 154

Test method for detection of copper corrosion form Petroleum Products by the copper strip tarnish test.

ASTD D445/IP 71

Test method for Kinematic viscosity of transparent and opaque mineral oil in the presence of water.

ASTM D892

Test method for forming characteristics of lubricating oils.

ASTM D943

Test method for oxidation characteristics of inhibited mineral oils.

ASTM D2270/IP 226

Practice for calculating viscosity index from kinematic viscosity at 40ºC to 100ºC.

ASTM D2711

Test method for demulsibility characteristics of extreme pressure lubricating oils.

ASTM D2893

Test method for oxidation characteristics of extreme pressure lubricating oils.

ASTM D4057

Standard practice for manual sampling of petroleum and petroleum products.

ZS 317

Road tank vehicles for petroleum based flammable liquids-specification.

ZS 385

The Petroleum Industry: Part 1 – Storage and distribution of petroleum products in above ground bulk installations –Code of Practice.

ZS 396

Sampling petroleum products: Part 1 – manual sampling of liquid hydrocarbons.

4. Definitions

For the purpose of this Standard, the following definitions apply:

Additive

A compound added to engine oil to enhance properties and performance.

ASTM method

The test method published by the American Society for Testing and Materials, in the United States of America.

ASTM reference sequence

The reference test sequence given in STP 315H, published by the American Society for Testing and Materials in the United States of America.

Base oils

Refined additive-free oils of varying viscosity grades, which are used in the manufacture of formulated lubricants.

FZG

Foschungstellie fur Zahnrader und Getriebau (Research Institute for Gears and Gear Design, Germany).

Gear oil

A liquid that reduces friction and wear between the moving parts within a power transmission system, serves as a coolant and may contains additives to enhance its performance and inhibit rusting, oxidation and foaming.

AGMA Lubricant Number

Numbering as defined in AGMA 251.02, published by the American Gear Manufacturers Association.

R and O Gear Oils

Petroleum-based oils with rust and oxidation inhibitors (R and O).

4.9. EP Gear Oils

   Gear oils that contain additives which prevent sliding metal surfaces from seizing under extreme pressure conditions.

4.10. IP method

   The test method published by the Institute of Petroleum, United Kingdom.

5.  Requirements

5.1 General

5.1.1 AGMA Lubricant based on an open-ended alphanumeric gear lubricant designations (AGMA ` to AGMA 13, inclusive for R and O Gear Oils and AGMA IEP to AGMA 13EP for EP Gear Oils) shall apply.

5.1.2   A marketer shall ensure that licensed open gear oils satisfied all bench testing performance requirements as stipulated in Table 1 to 4 of this standard and in selecting a particular lubricant, the user must take into account recommendations of the equipment manufacturer.

5.1.3   A manufacturer in the food and drug industry who uses lubricants recommended in this standard in food and drug industry applications shall ensure that accidental contact of the lubricant, with the products being manufactured in avoided.

5.2. Licensed Service Category

   A marketer of open gear oil marketed in Zambia shall ensure that open oil has a product data sheet which, apart from other proprietary information, shows all the details in Tables 1, 2, 3 and 4 together with the corresponding properties.

6.  Packaging and marking

6.1 Packaging

The condition of selling or transporting oil containers shall not be detrimental to the quality of the oil during normal storage or transportation and shall comply with the provisions and requirements of the following standards:

ZS 371    Road tank vehicles for petroleum based flammable liquids –specification.

ZS 385    The Petroleum Industry: Part I storage and distribution of petroleum products in above ground bulk installations –Code of Practice.

6.2 Marking

The following information shall appear in legible and indelible marking on an open gear oil containers apart from other proprietary information:

   (a)    product brand name;

   (a)   manufacturer’s name;

   (b)   ISO viscosity grade, or AGMA lubricant number or ASTM equivalent grade;

   (c)   Intended application;

   (d)   Quantity contained in litres or kilogrammes as applicable; and

   (e)   Safety, health and environmental information.

7.  Sampling

   Sampling shall be done in accordance with the provisions given in ZS 396 and ASTM D4057.

ZS 547 Part II:2011

Table 1 – AGMA Viscosity Grades for Open Gear Lubricants

AGMA Lubricant Number

ASTM Equivalent Grade

CorrespondingISO Viscosity

Viscosity Ranges in cSt @ 37.8 Deg C

R and O Gear Oils

EP Gear Oils

 

4

4EP

S700

150

135 to 165

5

5 EP

S1000

220

198 to 242

6

6 EP

S1500

320

288 to 352

7

7 EP

S2150

460

414 to 506

8

8 EP

S3150

680

612 to 748

9

9 EP

S7000

1500

1350 to 1650

10

10 EP

S15000

-

2880 to 3520

11

11 EP

S21500

-

4140 to 5060

12

12 EP

S31500

-

6120 to 7480

13

13 EP

S15000

-

25600 to 38400

Table 2 – Specification for R and O Gear Oils

Property

Test Procedure

Criteria for Acceptance

Viscosity

ASTM D 88

Must be as specified in Table 1

Viscosity Index

ASTM D2270/IP/226

*90 min

Oxidation stability

ASTM D 94 number of

Hours to reach a neutralisation

 

2.0mg KOH

   

AGMA Grade Hours (Mins

   

1 and 21 500

   

3 and 4750

   

5, 6, 7, and 8500

Rust Protection

ASTM D 665/IP/135

AGMA Lubricant Nos. 4 to 8 – no rust after 24 hours with synthetic sea water

Corrosion Protection

ASTM D 130/IP154

*#1 strip after 3 hours at 121 Deg ºC

Foam Suspension

ASTM D 892

*Must be within the limits specified in Table 4

Demulsibility

ASTM D2711

*Must be within the limits specified in Table 4

Cleanliness

None abrasives

Must be free from grit and

*Applicable to AGMA Lubricant Nos 4 to 8 only

Table 3 – Specification for EP Gear Oils

<FT:Calibri,SN>Property 58Test Procedure Criteria for Acceptance
Viscosity ASTM D 88 Must be as specified in Table 1
Viscosity Index ASTM D2270/IP/226 *90 min
Oxidation stability ASTM D 943 number of Hours to reach a neutralisation
2.0mg KOH
AGMA Grade Hours (Mins
1 and 21 500
3 and 4750
5, 6, 7, and 8500
Rust Protection ASTM D 665/IP/135 AGMA Lubricant Nos. 4 to 8 – no rust after 24 hours with synthetic sea water
Corrosion Protection ASTM D 130/IP154 *#1 strip after 3 hours at 121 Deg ºC
Foam Suspension ASTM D 892 *Must be within the limits specified in Table 4
Demulsibility ASTM D2711 *Must be within the limits specified in Table 4
Cleanliness None abrasives Must be free from grit and
     
     
     
Property Test Procedure Criteria for Acceptance
Viscosity ASTM D 88 Must be as specified in Table 1
Viscosity Index ASTM D2270 *90 min
Oxidation stability ASTM D 2893 *increase in Kinematic viscosity of oil sample @ 99 ºC degrees should not exceed 10 percent.
Rust Protection ASTM D 665 No rust after 24 hours with distilled water
Corrosion Protection ASTM D 130 *#1 strip after 3 hours at 99 degrees(ºC)
Foam Suspension ASTM D 892 *Must be within the limits specified in Table 4
Demulsibility ASTM D2711 *Must be within the limits specified in Table 4
EP Property Timken Test An oil which passes either a 20Kg Timken OK load or 9 stages on the FZG machine is considered acceptable.
Additive Solubility None Must be filterable to 100 microns (wet or dry) without loss of EP additive

*Applicable to AGMA Lubricant Nos. 4EP to 8EP only.

Table 4 – Test Procedure and Limits

1.0. Test Limits – ASTM D892 Foam Test

   
   

Max Volume of Form (ml) After

 
       
 

Temperature

5 Minutes Blow

10 Minutes Rest

Sequence I

24ºC

75

10

Sequence II

93ºC

75

10

Sequence III

24ºC

75

10

2.0 Test Limits – ASTM D2711 Demulsibility

Max percent water in the oil after 5-hour test

0.50%

Max cuff after centrifuging

2.0 ml

Min total free water collected during entire test

30 ml

3.0 Test Limits – ASTM D2711 Demulsibility Test (Modified for EP oils para 3.2.,ASTM D2711-69

 

AGMA Grades

       

Max percent water in the oil after 5 – hour test

2 EP to 6 EP

7 EP to 8 EP

 

Max cuff after centrifuging

1.0 m%

1.00%

 

Min total free water collected during entire

2.0 ml

4.0 ml

 

Test (Start with 90 ml of water)

60 ml

50 ml

 

ZAMBIA BUREAU OF STANDARDS

ZS 547 Part III: 2011

LUBRICATING OILS – SPECIFICATION

 

Part III
INDUSTRIAL GEAR OILS FOR ENCLOSED GEARS

1.  Scope

1.1   This Zambian Standard specifies requirements for mineral gear oils suitable for enclosed gear operating at various speeds and shock loadings.

1.2   The industrial gear oil shall be a mineral oil blended with additives to provide the requisite level of oxidation and thermal stability, rust and wear protection, demulsibility and foam inhibition for the intended application.

1.3   Industrial gear oil acceptance criteria in terms of quality and performance level shall primarily be based on the performance criteria stipulated by original equipment manufacturers such as David Brown and by institutions such as AGMA, ISO, Croft and US Steel.

2.  NOTE

<FC:0,0,0,DC><BC:0,0,0,DC> AGMA

American Gear Manufacturer’s Association

API

American Petroleum Institute

ASTM

American Society for Testing and Materials

DIN

Deutsches Institute fur Normung (German Standards Institute)

SAE

Society of Automotive Engineers

API

American Petroleum Institute

ISO

International Organisation for Standardisation

SABS

South African Bureau of Standards

eSt

centi Stokes

mgKOH/g

milligrammes of potassium hydroxide per gramme of oil

<FC:0,0,0,DC><BC:0,0,0,DC>3.    Normative references

In this Standard, reference has been made to the following standards:

<BC:0,0,0,DC>ASTM D92/IP 36

Test method for flash and fire points by Cleveland Open Cup (COC)

ASTM D445/IP 71

Test method for Kinetic viscosity of transparent and opaque liquids (the calculation of dynamic viscosity).

ASTM D2270/IP 226

Practice for calculating viscosity index from kinematic viscosity at 40ºc and 100 ºc.

ASTD D97/1P/15

Test method for pour of Petroleum Product.

ASTM D 664

Total acid number of petroleum products by potentiometric titration.

ASTM D665/IP 135

Test method for rust preventing characteristics of inhibited mineral oil in the presence of water.

ASTM 943

Test method for oxidation characteristics of inhibited mineral oils

ASTM D2270/IP 226

Practice for calculating viscosity index from Kinematic viscosity at 40ºc and 100 ºc.

ASTM D 2893

Test method for oxidation characteristics of extreme pressure lubricating oils

ASTM D4057

Standard practice for manual sampling of petroleum and petroleum products

DIN 51354/IP334

Load carrying capacity test for oils – FZG Gear machine

ZS 317

Road tank vehicles for petroleum based flammable liquids-specification.

ZS 385

The Petroleum Industry: Part 1 – Storage and distribution of petroleum products in above ground bulk installations –Code of Practice.

ZS 396

Sampling petroleum products: Part 1 – manual sampling of liquid hydrocarbons.

4. Definitions

For the purpose of this Standard, the following definitions apply:

4.1    Additive

Material added to engine oil to enhance properties and performance.

4. 2     ASTM method

The test method published by the American Society for Testing and Materials.

4.3    ASTM reference sequence

The reference test sequence given in STP 315H, published by the American Society for Testing and Materials.

Base oils

Refined additive-free oils of varying viscosity grades, used in the manufacture of formulated lubricants.

4.5 Compound Gear Oil

Oil marked ‘Comp’ and compounded with 3% to 10% fatty or synthetic fatty oils.

4.6 Gear oil

A liquid that reduces friction and wear between the moving parts within a power transmission system, serves as a coolant and may contains additives to enhance its performance and inhibit rusting, oxidation and foaming.

4.7    Extreme Pressure Additive

Lubricant additive that prevents sliding metal surfaces from seizing under extreme pressure conditions.

4.7   FZG

Foschungstelle fur Zahnrader und Getriebau (Research Institute for Gear and Gear Design Germany).

4.9 IP Method

The test method published by the Institute of Petroleum in the United Kingdom

5. Requirements

5.1 General

5.1.1    Industrial Gear oils shall comply with the requirements detailed in Table 1 and Table 2.

5.1.2   An industrial gear oil shall not contain any lead additives.

5.1.3   A marketer shall ensure that all industrial gear oils marketed in Zambia has a product data sheet which, apart from other proprietary information, contains all the details listed in Table 1 and Table 2 together with the corresponding properties.

6.  Packaging and marking

6.1    Packaging

The condition of selling or transporting oil containers shall be such as not to be detrimental to the quality of the oil during normal storage or transportation and shall comply with the provisions and requirements of the following standards:

ZS 371    Road tank vehicles for petroleum based flammable liquids –specification.

ZS 385    The Petroleum Industry: Part I storage and distribution of petroleum products in above ground bulk installations –Code of Practice.

6.2    Marking

   All industrial gear oil containers shall bear apart from other proprietary information the following details.

   (a)    product brand name;

   (b)    manufacturer’s name;

    (c)    quantity contained in litres; and

    (d)    Safety, health and environmental information.

7.  Sampling

Sampling shall be done in accordance with the provisions given in ZS 396 and ASTM D4057.

ZS 547 Part III: 2011

Table 1: Minimum requirements for EP industrial gear oil

TEST

TEST METHOD

REQUIREMENTS

ISO VG

Not Applicable

68

100

150

220

320

460

680

1000

AGMA

Not Applicable

2 EP

3 EP

4EP

7EP

7EP

7EP

8EP

8AEP

CROFT Designation

Not Applicable

B

C

D

E

F

G

-

-

David Brown Number

Not Applicable

2

3

4

5

6

7

8

9

Product Identity

Not Applicable

Brand name

Brand name

Brand name

Brand name

Brand name

Brand name

Brand name

Brand name

Viscosity at 40ºc, eST

ASTM D445/IP 71

61.2-74.8

90-110

135-165

198-242

288-352

414-506

612-748

900-1100

Viscosity Index


(min)

ASTM D 2270/IP 226

90

90

90

90

90

90

90

90

Pour Point, ºc (Max)

ASTM D97/IP 15

27

24

22

20

18

9

6

3

Flash Point (COC), ºc (min)

ASTM (COC) ºC (min)

200

200

200

200

200

200

200

200

Total Acid Number, KOH/g(max)

ASTM D 664/IP 177

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5mg

FZG failure load stage (min)

ASTM D 51354/IP 334

>12

>12

>12

>12

>12

>12

>12

>12

Rust Prevention

ASTM D665/IP 135

Pass

Pass

Pass

Pass

Pass

Pass

Pass

Pass

Foaming characteristic Sequence I (max)

ASTM D 892/IP 146

10/0

10/0

10/0

10/0

10/0

10/0

10/0

10/0

Sequence II (max)

50/0

50/0

50/0

50/0

50/0

50/0

50/0

50/0

50/0

Sequence III (max)

10/0

10/0

10/0

10/0

10/0

10/0

10/0

10/0

10/0

Oxidation

ASTM

Increase in Kinematic viscosity of oil sample at 95 ºC should not exceed stability D2893 10%

Table 2: Minimum requirements for general industrial, gear oils-rust and oxidation oils

TEST

TEST METHOD

REQUIREMENTS

ISO VG

Not Applicable

68

100

150

220

320

460

680

1000

AGMA Designation

Not Applicable

2

3

4

5

6

7 COMP1

8 COMP1

8A COMP1

David Brown Number

Not Applicable

2M

3M

4M

5M

6M

7M

8M

9M

Product Identity

Not Applicable

Brand name

Brand name

Brand name

Brand name

Brand name

Brand name

Brand name

Brand name

Viscosity at 40ºc, eST

ASTM D445/IP 71

61.2-74.8

90-110

135-165

198-242

288-352

414-506

612-748

900-1100

Viscosity Index (min)

ASTM D 2270/IP 226

90

90

90

90

90

90

90

90

Pour Point, ºc (Max)

ASTM D97/IP 15

27

24

22

20

18

9

6

3

Flash Point , ºc (min) (COC)

ASTM D 92 IP 54

200

200

200

200

200

200

200

200

Total Acid Number, mgKOH/g(max)

ASTM D 664/IP 177

1.5

1.5

1.5

1.5

1.5

1.5

1.5

1.5mg

Foaming characteristic Sequence I (max)

ASTM D 892/IP 146

10/0

10/0

10/0

10/0

10/0

10/0

10/0

10/0

Sequence II (max)

50/0

50/0

50/0

50/0

50/0

50/0

50/0

50/0

50/0

Sequence III (max)

10/0

10/0

10/0

10/0

10/0

10/0

10/0

10/0

10/0

Oxidation

ASTM D2893

Increase in Kinematic viscosity of oil sample at 95 ºC should not exceed stability 10% stability

Oxidation stability

ASTM D943

Hours to reach a neutralisation number of 2.0
ISO VGHours (Min)
46, 681,500
100,150750
200,320500

Note: Oils marked ‘Comp’ are compounded with 3% to 10% fatty or synthetic fatty oils.

 

SECOND SCHEDULE

[Paragraph 3]

1.ZS 547 PART 1   Lubricating oils-automotive gear oils

2.ZS 547 PART 2   Lubricating oils-industrial gear oils for open gears

3.ZS 547 PART 3   Lubricating oils –industrial gear oils for enclosed gears.

 

STANDARDS (COMPULSORY STANDARDS) (FEES) REGULATIONS, 2012

[Section 37]

Arrangement of Regulations

Regulation

   1. Title

   2. Fees

      SCHEDULE

SI 49 of 2012.

 

1. Title

These Regulations may be cited as the Standards (Compulsory Standards) (Fees) Regulations, 2012.

 

2. Fees

The fees set out in the Schedule are payable by an importer or manufacturer of a product to which a compulsory standard applies.

 

SCHEDULE

[Regulation 2]

CERTIFICATION FEES FOR COMPULSORY STANDARDS

A. IMPORT FEES

Item

Consignment(s*)CIF Value (ZMK)

Fee units

1. Application fee

 

1,528 (per application)

2. Inspection of an imported consignment

 

3,611

3. Certification of a consignment and imported certificate annual

All values

0.5% of FOB

4. Application for annual import certificate

All values

25,556

B. DOMESTIC FEES

Item

Annual Ex-Factory Income (,000,000,000 ZMK)

Fee units

1. Application fee

....................

1,528 (per application)

2. Inspection of a factory establishment

....................

4,166 per inspector days

3. Annual product certification

Up to 100


101 – 500
Greater than 500

0.15% of ex-factory income with a minimum of 5,556

0.075% of ex-factory income
0.05% of ex-factory income

4. Inspection fee – road tanker

....................

4,722 (per road tanker)

5. Inspection fee – pre-fitted road


speed limiter

....................

1,944 (per pre-fitted road limiter)

6. Inspection fee - timber

....................

139 (per m)

C. TESTING FEES

Product Type

Tests

Fee Units

1. Meat, Poultry, Fish,Vegetables, Fruits,Oils, Fats, Grains, Dairy Products, Animal Feed, Non-Alcoholic Beverages, Water

Physical

Chemical

Residual anti-biotics, pesticides, Fungicides, hormones and vitamins

Microbiological

1,944 per sample

3,387 per sample

1,985 per Parameter


3,389 per sample

2. Bakery products

Physical
Chemical

Residual anti-biotics, pesticides, Fungicides, hormones and vitamins
Microbiological

1,944 per sample
3,387 per sample

1,985 per Parameter

3,387 per sample

3. Alcoholic Beverages

Physical
Chemical

Residual anti-biotics, pesticides, Fungicides, hormones and vitamins
Microbiological

1,944 per sample
4,612 per sample

1,985 per parameter

3,387 per sample

4. Leather, Textiles, Wood, Paper, Rubber, Plastics and related products

Physical
Chemical

7,778 per sample
3,256 per sample

5. Refined petroleum products

Physical
Chemical
Hydrocarbons

3,256 per sample
3,256 per sample
1,985 per parameter

6. Basic chemicals, fertilizers, nitrogen compounds, paints, vanishes, soaps, Detergents, cleaning and polishing preparations, toilet preparations, and related products

Physical
Chemical

3,167 per sample
3,167 per sample

7. Cement, lime, plaster, articles of concrete basic iron, steel, ferro-alloys, bars, wires, tubes, pipes, hollow profile and related fittings of steel; copper and other non-ferrous alloys; cast metal products, computer, electronic and optical products, electrical equipment

Physical


Chemical

13,889 per sample


13,889 per sample

 

STANDARD (COMPULSORY STANDARDS) (CHALK) (DECLARATION) ORDER, 2013

[Section 7]

Arrangement of Paragraphs

   Paragraph

   1. Title

   2. Declaration of compulsory standards

      SCHEDULE

SI 44 of 2013.

 

1. Title

This Order may be cited as the Standards (Compulsory Standards) (Chalk) (Declaration) Order, 2013.

 

2. Declaration of compulsory standards

The standards set out in the Schedule apply to school chalk and are declared as compulsory standards.

 

SCHEDULE

[Paragraph 2]

ZAMBIA BUREAU OF STANDARDS

Zambian Standard

SCHOOL CHALK — Specification

ZS 071:2012

SCOPE,

This Zambian Standard specifies the materials, size, mass, free moisture and breaking strength of moulded white and coloured chalks primarily intended for writing on chalkboards.

REQUIREMENTS

2. 1 Materials

Chalk shall be made from calcined gypsum and to this may be added other materials for pigmentation or other manufacturing processes. Chalk shall not contain, in quantities which may cause harm to the health of a person, silica, aluminium, iron, phosphorous, sulphur, manganese, copper, titanium, sodium oxide, potassium oxide, fluorine, arsenic or strontium. Chalk shall be of homogenous mass, free from grease, grit, sandy abrasives and not leave more than 50 percent of residue when passed a 250 jam sieve.

2. 2 Finish

2.2.1 Chalk shall beof smooth uniform shapeand size,circular in cross- section, tapered at one end and free from external blow-holes.

2.2.2 Chalkshallproducefreely, without scratching or damaging chalkboards, visible and distinct marks that can easily be erased with a dry eraser.

2.2.3 Chalk shall, when tested, comply with the requirements in table 1.

TABLE 1: REQUIREMENTS FOR SCHOOL CHALK

SL No.

Characteristics

Requirements

(i)

Calcium sulphate (as CaSO4. 1/2H2O) minimum percent by mass

80

(ii)

Maximum free moisture percent by mass

15

(iii)

Length of stick (millimetres)

80+3

(iv)

Diameter at thicker end (millimetres)

11+1

(v)

Diameter tapered end (milimetres)

9+1

(vi)

Minimum mass per 100 sticks (grammes)

500

(vii)

Minimum transverse breaking strength, (kilogrammes)

0.9

3. PACKING

Chalk shall be tightly packed in suitable paperboard boxes which prevent damage of chalk during transportation. A box of chalk shall contain one hundred pieces of chalk, unless otherwise agreed between a purchaser and a supplier.

4.1A box of chalk shall be marked on the outside with the following:

   (a)   the name of the product;

   (b)   the colour of the chalk;

   (c)   the number of pieces of chalk in the box;

   (d)   the manufacturer’s name or trade-mark; and

   (e)   an identification mark or code for tracing records from the lot of manufacture.

 

STANDARDS (COMPULSORY STANDARDS) (DECLARATION) ORDER, 2013

[Section 7]

Arrangement of Paragraphs

   Paragraph

   1. Title

   2. Declaration of compulsory standards

   3. Application of standards

      SCHEDULES

SI 59 of 2013.

 

1. Title

This Order may be cited as the Standards (Compulsory Standards) (Declaration) Order, 2013.

 

2. Declaration of compulsory standards

The standards set out in the First Schedule are declared as compulsory standards.

 

3. Application of standards

The standards set out in the First Schedule shall apply to the respective commodities listed in the Second Schedule.

 

FIRST SCHEDULE

[Paragraph 2]

COMPULSORY STANDARDS

ZAMBIA BUREAU OF STANDARDS

Zambian Standard 688

 

PART 1
GENERAL

ELECTRIC CABLES WITH EXTRUDEDSOLID DI-ELECTRIC INSULATIONFOR FIXED INSTALLATIONS

(300/500 V, 600/1000 TO 1 900/3 300 V) – SPECIFICATION

1. Scope

   1.1 This Part of the Zambian standard specifies the requirements for packing and marking, and informative Annexes for single-core and multicore extruded solid di-electric insulated cables of rated operating voltage (U0/U) in the range 300/500 V, 600/1 000 V and 1 900/3 300 V, for use in fixed installations, as covered by Zambian standard ZS 688-2 to ZS 688-6.

   1.2 Specific requirements are given for the types cables in common use which are–

   (a)   single-core and multicore cables, armoured and unarmoured;

   (b)   multicore flat cables with and without an earth continuity conductor;

   (c)   multicore round cables with aluminium/PVC laminate and an earth continuity conductor;

   (d)   cables with concentric conductors;

   (e)   cables with split concentric neutral and earth conductors;

   (f)   panel/cubicle cables, excluding flexible cables and cords; and

   (g)   insulated earth conductors. 

   1.3 This specification also covers cables that reduce the overall risk associated with fires.

2. Terms and definitions

For the purposes of this Part of ZS 688, the following definitions shall apply:

2.1 Acceptable

Acceptable to the authority administering this standard or to the parties concluding the purchase contract, as relevant.

2.2 Armour

A layer of wires applied to a cable to provide mechanical protection or earth continuity, or both.

2.3 Bedding

A layer of extruded compound applied to a cable to form a circular base beneath the armour in order to prevent damage to the insulation by the armour or to form a base for the sheath.

2.4 Cable

One or more cores with or without an overall protective covering.

2.5 Concentric conductor

A conductor in the form of a single layer of wires that are laid helically around one or more central cores.

2.6 Core

A single insulated conductor without protective covering.

2.7 Di-electric

The covering of a conductor that is intended to insulate the conductor electrically.

2.8 Di-electric of lay

The lateral direction of inclination to the axis (either left hand or right hand) of the receding helix formed by a wire or a core in a cable.

2.9 Filler

The material that fills the interstices of the cores of a multicore cable.

2.10 Fire retardant cable

A cable modified in construction or composition, or both, and contains properties which are less affected by fire.

2.11Flame propagation

Spreading a flame along a cable or cables under defined fire conditions.

2.12 Halogen emission

The release of halogen gas from cable material under defined fire conditions.

2.13 Lay ratio

The ratio of the axial length of a complete turn of the helix formed by an individual core in a multicore cable to the pitch circle diameter of the helix formed by the same core.

2.14   Operating voltage is the voltage designation of cables U0/U (Um) as follows:

U0- is the rated power frequency voltage between conductor and earth for which the cable is designed;

U – is the rated power frequency voltage between conductors for which the cables is designed;

and

Um– is the maximum value of the highest system voltage for which the equipment may be used.

2.15 Routine test

A test conducted on the manufacturer’s works on all cable lengths during manufacture after the manufacture of the cables.

2.16 Sample test

A test conducted on a regular basis on the manufacturer’s works or on representative samples taken by the manufacturer, or as requested by the purchaser at the time of enquiry or order.

2.17 Sheath

An extruded protective covering applied to a cable.

2.18 Turned core

A core found in a shaped conductor cable that has, at any point along the length of the cable, deviated from its intended angular orientation.

2.19 Type test

A test conducted before a type of cable covered by this standard is supplied on a general commercial basis, in order to demonstrate that the cable has the necessary performance characteristics for the intended application. The test, when successfully completed, need not be repeated unless changes are made in the cable materials or design that might change the performance characteristics of the cable.

ABBREVIATIONS

2.20 ECC

Earth Continuity Conductor

3. Packing and marking

   3.1   Packing

Cables shall be packed on drum, reels or in coils.

   3.1.1   Drums and reels

The moisture content of the wood of a wooden drum or reel shall not exceed 20 %. Where wooden drums or reels are required to be resistant to biological attack, the wood shall be impregnated (by pressure or in a hot or cold open tank) in accordance with ZS 771 with a class C preservative or with chromatid copper arsenate.

   3.1.2   Cable ends

Each end of the cable shall, before being secured to the drum or reel, be sealed by an acceptable method. The outer end shall be secured to the drum or reel, and the inner end shall be protected in an acceptable manner against mechanical damage.

   3.2   Marking

   3.2.1   Marking of cables

The information listed in the following paragraphs shall appear in legible and indelible marking on the external surface of each finished cable:

   (a)   the manufacturer’s name, trade name or trade mark;

   (b)   the operating voltage (U) for which the cable has been designed, given in volts or kilovolts(e.g. 500 V, 1 000 V or 3.3 kV), in two lines on opposite sides of the cable where the cable overall diameter exceed 15 mm;

   (c)   when applicable, information on the special properties of the cables in accordance with column 3 of table 1 (Optional additional marking can be done in accordance with column 2); and

   (d)   where required, a marking that indicates the cross-sectional area and the number of cores.

The letters and numerals shall be upright characters of maximum height of 13 mm and minimum height of 3 mm. In the case of cables that have an overall diameter of less than 6 mm, the height area of the characters may be less than 3 mm provided that the legend is acceptably legible. The gap between the end of one legend and the beginning of the next shall not exceed 150 mm.

Table 1 — MARKING OF CABLES

Property

Marking

Colour of strips

General purpose

No stripe

Reduced smoke emission

LS

No stripe

Reduced halogen emission

LH

No stripe

No halogen emission

NHN

No stripe

Reduced flame propagation

FR

Red

Reduced halogen emission and reduced propagation

LHFR

Blue

No halogen, reduced smoke emission and reduced propagation

NHLSER

White

   3.2.2   Marking of coils

Each coil package shall bear the following information in legible and indelible marking:

   (a)   the manufacturer’s trade name or trade mark or both;

   (b)   the rated voltage, the cross-sectional area of phase conductor(s), and the number of cores; and

   (c)   the length of cable.

   3.2.3   Marking of drums or reels

Each drum or reel shall bear the following information in legible and indelible marking:

   (a)   the information required in 3.2.2;

   (b)   a brief cable description;

   (c)   the gross mass;

   (d)   an identifying serial number;

   (e)   unless the manufacturer guarantees that the drum or reel may be laid flat without damage to the cable, the words “NOT TO BE LAID FLAT” (in capital letters), or a suitable pictogram;

   (f)   unless the manufacturer guarantees that the drum or reel may be rolled in either direction without damage to the cable, an arrow or the words “ROLL THIS WAY” (in capital letters, to indicate the direction in which the drum or reel is to be rolled in order to prevent the cable from unwinding); and

   (g)   if the wood of the drum or reel has been treated, a capital letter “T” of approximate height 50 mm surrounded by a circle of approximate outside diameter 65 mm.

ANNEX A

(Informative)

NOTES TO PURCHASERS

   A.1   Before the purchaser orders cables produced to this specification, it is suggested that the following points be considered:

   A.1.1   Identification of cores

The identification of cores, particularly in power cables, should preferably be done by colour coding.

Identification by numbers is also acceptable. The neutral must always be black or carry the number -0-, or both. Particular care should be taken to select the correct colours when a three-core or four-core cable intended for use on single-phase circuits is being ordered.

   A.1.2   Current rating

The current rating of the cable and the applicable rating factors for a particular installation should be ascertained from the cable manufacturer. This information is also given in ZS 772.

   A.1.3   Type of cable

Careful consideration should be given to the type of cable to be used for a particular installation. Alternatives such as copper or aluminium conductors, conventional PVC insulation and sheathing flame-retardant, low smoke emission, halogen-free cables, armoured or unarmoured cables, should be considered.

   A.2   it is recommended that the following requirements be specified in invitations to tender and in each order or contract:

   (a)   the maximum permissible operating voltage;

   (b)   the conditions of service of the cable;

   (c)   the conductor material (copper, tinned copper or aluminium) and the type of conductor;

   (d)   the type of insulation material;

   (e)   colour coding or numbering of cores;

   (f)   the type of bedding material;

   (g)   whether the cable is to be armoured;

   (h)   if the cable is to be armoured, the material of the armour wires;

   (i)   in the case of a cable with steel wire armour, whether an earth continuity conductor (ECC) is required;

   (j)   the type of material of the sheath;

   (k)   in the case of a cable with a metallic sheath, whether the metal is to be lead or lead alloy of type (see Annex B of EN 12548:1999);

   (l)   whether fire retardant properties are required;

   (m)   in the case of cables packed on wooden drums, whether the wood of the drum is to be resistant to biological attack; and

   (n)   whether the number of cores and the cross-sectional area are to be indicated on the cable.

   A.3ZS IEC 60332-3 denotes four optional categories, namely A, B, C and D. Current research indicates that cables that satisfy the requirements for Category C, comply with the flame propagation requirements for steel wire armoured cables in accordance with both national and international standards.

ANNEX B

(Informative)

QUALITY EVALUATION OF EXTRUDED SOLID DI-ELECTRIC INSULATED CABLES

When a purchaser requires ongoing verification of the quality of extruded solid di-electric cables, it is suggested that, the purchaser should, instead of concentrating solely on evaluation of the final product, also direct attention to the manufacturer’s quality system and consider Zambian condition ZS 150 9001 which makes provision for an integrated quality system.

ANNEX C

(Informative)

INSTALLATION OF EXTRUDED SOLID DI-ELECTRIC INSULATED CABLES

   C.1Information on the installation of extruded solid dielectric insulated cables

Information on the installation of extruded solid dielectric insulated cables is given in ZS 777-2 and ZS 777-8.

   C.2Minimum installation bending radii

Although cables that comply with this specification are designed to have a certain flexibility, it is necessary that bending (and any subsequent straightening) be done slowly and carefully. The radii of bending given in table C.1 (measured on the inside of the bent cable) represent recommended minimum values and should be exceeded whenever possible.

Table C.1 — RECOMMENDED MINIMUM INSTALLATION BENDING RADII

Construction of cable

Cable diameter D, mm

Minimum installation bending radius

Exceeding

Not exceeding

Insulated only

10

3 D

Insulated only

10

25

4D

Insulated only

25

40

6 D

Insulated only

40

8 D

Sheathed only

Armoured

10 D

Lead sheathed

15 D

   C.3Voltage test for cables after installation

After installation, the cable may, if so required, be subjected to the appropriate test voltage given in table C.2. The test voltage (either ac or dc) should be applied between conductors and between each conductor and the metallic protection or earthed surroundings of the cable, as appropriate. it should be increased to the full appropriate value, and maintained at this value for 15 min.

Table C.2 — Test Voltages after Installation

Cable operating voltage

Where test voltage is to be applied

Test voltage V

<

de

300 / 500

Betweenconductors or conductors and earth

1 000

1 500

600/ 1 000

Between conductors or Conductors and earth

2 000

3 000

1 900 3 300

Between conductors

6 000

9 000

 

Between conductors and earth

3 500

5 000

 

PART 2
WIRING CABLES

ELECTRIC CABLES WITH EXTRUDEDSOLID II-ELECTRICINSULATIONFOR FIXED INSTALLATIONS

(300/500 V, 600/1000 V AND 1 900/3 300 V) -SPECIFICATION

1. Scope

1.1 This Part of the Zambian Standard specifies the requirements for construction, materials, dimensions and electric properties of unarmoured single-core and multicore extruded solid dielectric insulated cables with rated operating voltages (Uo/U) of 300/500 V and 600/1 000 Vand a conductor cross-sectional area of 16 mm2 for use in fixed installations.

1.2 Specific types of cables covered by this Part are the following:

   (a)   insulated wires (600/1 000 V);

   (b)   multicore flat and circular sheathed cables (300/500 V);

   (c)   single-core unsheathed panel/cubicle cables (300/500 V); and

   (d)   multicore round cables with aluminium/PVC laminate and an earth continuity conductor (300/500 V).

2. Normative references

In this standard, reference has been made to the following standards:

ZS 756-1 Materials of insulated electric cables and flexible cords – Part 1: Conductors;

ZS 756-2 Materials of insulated electric cables and flexible cords – Part 2: Polyvinyl chloride (PVC);

ZS 688-1 Electric cables with extruded solid dielectric insulation for fixed installations (300/ 500 V to 1 900/3 300 V) – Part 1: General;

ZS 772 The wiring of premises – Part 1: Low-voltage installations;

ZS IEC 60811-1-1, Common test methods for insulating and sheathing materials of electric cables – Part 1: Methods for general application – Section 1: Measurement of thickness andoverall dimensions – Tests for determining the mechanical properties;

ZS 764 Alternating current spark test on electric cables and cords;

ZS 765 Dielectric resistance of electric cables; and

ZS 769-3 Test methods for cross-linked polyethylene (XP).

NOTE

All standards are subject to revision and, since any reference to a standard is treated as a reference to the latest edition of that standard, parties to agreements based on this Part of ZS 688 are encouraged to take steps to ensure the use of the most recent editions of the standards indicated. Information on currently valid national and international standards can be obtained from the Zambia Bureau of Standards.

3. Definitions

For the purposes of this Part of the Zambian standard ZS 688, the definitions providedin Zambian standard ZS 688-1 shall apply.

4. General requirements

4.1   Cable Operating Voltage

The maximum permissible operating voltage of a cable shall be either 300/500 V or 600/1 000

V with the ( Um) for the 600/1000V (1.2 kV).

4.2 Materials and Construction

4.2.1   Conductors

A conductor shall be of plain or tinned annealed copper, as required, and shall comply with the requirements of ZS 756-1.

4.2.2    Insulation

4.2.2.1 Material

The insulation shall be extruded PVC complying with the requirements for insulation grade PVC of ZS 765-2.

4.2.2.2 Thickness and insulation resistance

4.2.2.2.1Unless otherwise stated in the relevant specific requirements given in clause 5, the nominal thickness and the insulation resistance of the insulating material shall comply with the requirements given in table 7, as appropriate to the cross-sectional area of the conductor and operating voltage.

4.2.2.2.2 When the thickness of the insulation is determined in accordance with ZS IEC 60811-1-1, the average thickness shall be at least equal to the nominal value, and the minimum thickness at any point may be less than the nominal value, except that the difference shall not exceed 0.1 mm + 10 % of the nominal value.

4.2.2.3 Spark resistance of insulation

All core insulation shall be spark tested using the method given in Zambian standard ZS 764 at an ac rms test voltage of 5 000 V in the case of 300/500 V cables, or at 6 000 V in the case of 600/1 000 V cables, without breakdown of the dielectric. Alternatively a dc test voltage 1.5 times the appropriate ac rms test voltage may be used.

4.2.3   Core identification

4.2.3.1 Identification

Cores shall be identified durably and distinctly by colouring as specified in table 1.

4.2.3.2   Earthing cores

Where an earthing core is not bare it shall be coloured green and yellow, and the combination of the colours shall be such that one colour covers not less than 30 % and not more than 70 % of the surface of the core, and the other covers the remainder of the surface. There shall be no green or yellow coloured core in a two-core cable or in any non-earthing type cable.

NOTE: The combination of green/yellow is reserved exclusively for the identification of the earthing core.

Table 1 – CORE IDENTIFICATION

Numbers of phase cores

Colours (s)of phase cores

Colour of neutral core

Colour of earthing core (if present and not bare

Colour of special purpose core (if present)

1

Any, except green

1

Red

Black

Green / yellow

Orange

2

Red and yellow

Black

Green / yellow

Orange

3

Red, yellow and blue

Black

Green / yellow

Orange

4 or more

Any ase colour except green and orange with with serial numbers (numerals or words)

     

4.2.4   Assembly of cores

4.2.4.1 General

The cores of a multicore cable shall be compactly laid up with an acceptable lay and in the correct sequence of their identification colours or numbers.

4.2.4.2 Fillers

Fillers may be applied integrally with the bedding or the sheath, as applicable, and shall be used in the interstices of the cable where necessary to give the completed cable a compact circular cross-section. Filler materials shall be such as to be acceptable for the specific type of cable.

4.2.4.3 Binder

A binder may be applied over the laid-up cores and the material shall be such as to be acceptable for the specific type of cable.

4.2.5   Sheaths

4.2.5.1 General

Sheaths shall consist of a continuous extrudate that closely fits but does not adhere to the underlying core or assembled cores. The surface of the extrudate shall have a smooth finish and its profile shall be uniform and appropriate to the type of cable.

4.2.5.2 Material

The sheath shall consist of an extruded layer of PVC of type S1 to S4 of ZS 756-2.

4.2.5.3 Thickness

4.2.5.3.1 Unless otherwise stated in the relevant specific requirements given in paragraph 5, the nominal thickness of the sheath shall be as stated in table 2.

4.2.5.3.2 When the average thickness of the sheath is determined in accordance with ZSIEC 60811-1-1, nominal value provided that the difference does not exceed 0.1 mm + 15 % of the nominal value.

Table 2 —THICKNESSOF SHEATH

Nominal diameter under sheath mm

Thickness of sheath mm

Unarmoured cable Nominal

Minimum


<<10>


1.6


1.26


>10 <<15


1.8


1.43


>15 <<20>


1.8


1.43


>20 <<25


2.0


1.60


>25 <<30


2.0


1.60

>30 <<35

2.2

1.77

4.3Electrical Requirements for Finished Cables

4.3.1Conductor resistance

The dc resistance of each conductor shall not exceed the appropriate maximum value given in ZS 756-1.

4.3.2Voltage withstand

When a cable is factory tested in accordance with ZS 769-3, each core of the cable shall withstand, for 10 min without breakdown of the dielectric, a test voltage of the appropriate value given in column 3 or 4 of table 3. Alternatively, the test may be conducted for 5 minutes at a test voltage of the appropriate value stated in column 5 or 6 of table 3.

Table 3 — TEST VOLTAGES

Cables

Alternating current rms test voltage V


Rated voltage V


Type or cross- sectional area


10 minute test


5 minute test

   

Between conductors

Between any conductor

Between conductor and earth

Between any conductors and earth

300/500

Single core cable or panel / cubicle cable

1 200

1 800

300/500

Multicore cable

1 500

1 500

2 250

2 250

600/1 000

Cables of cross sectional areanot exceeding 16 mm2

2 000

2 000

3 000

3 000

4.3.3   Di-electric resistance

When a cable is tested in accordance with ZS 765, the insulation resistance of the cable shall be at least equal to the value given in the appropriate columns of tables 5, 6 and 7.

5. Specific requirements for types of cable in common use

5.1   Insulated Wire (600/1 000 V)

5.1.1   Construction

The conductor shall be circular stranded, annealed copper complying with the requirements of Zambian standard ZS 756-1, class 2. The insulation shall be coloured as stated in table 1 and shall meet the requirements of PVC type D1 or D2 of ZS 756-2.

5.1.2 Requirements

The thickness and insulation resistance of the PVC insulation shall comply the stipulations of columns 5, 6 and 7 in table 7.

5.2 Multicore Flat and Circular Sheathed Cables (300/500 V)

5.2.1   Construction

Each core of a multicore cable shall consist of a circular solid or stranded annealed copper conductor.

The insulation shall be coloured as stated in table 1 and shall meet the requirements of PVC type D1 or D2 of ZS 756-2.

The cores shall be adjacent in a circular or flat arrangement and shall be sheathed. The sheath shall completely surround the cores, shall be close fitting but shall not adhere to the cores. An uninsulated annealed copper earth continuity conductor, as stated in column 6 of table 5, may be included between the cores.

5.2.2   Requirements

Each cable shall be manufactured in compliance with the relevant requirements given in table 5.

5.3 Single-Core Unsheathed Panel / Cubicle Cables (300/500 V)

5.3.1   Construction

A single-core cable shall consist of a circular solid annealed copper conductor which shall be manufactured in compliance with the requirements of table 6. The insulation shall be coloured as per table 1 and shall meet the requirements of PVC type D1 of ZS 756-2.

5.3.2   Requirements

Each cable shall be manufactured in compliance with the relevant requirements given in table 6.

5.4 Circular Sheathed Multicore Cables With Bare Earth Continuity Conductors and Aluminium/ PVC Laminate (300/500v)

5.4.1 Cables shall have 2, 3 or 4 cores, coloured as stated in table 1.

5.4.2 Cables shall have solid or stranded conductors as stated in table 5.

5.4.3 Insulation thickness and insulation resistance shall be manufactured in compliance with columns 2, 3 and 4 of table 7.

5.4.4   Aluminium laminate shall consist of longitudinally applied aluminium tape of minimum thickness 0.1 mm, covered by a sheath.

5.4.5   Earth continuity conductors shall be tinned annealed copper and shall comply with the requirements given in table 5.

5.4.6   Earth continuity conductors for a four-core cable shall be manufactured in compliance with the requirements set out intable 5 for a three-core cable.

5.4.7   The sheath shall consist of extruded PVC that complies with type S1 of ZS 756-2.

5.4.8   The thickness of the sheath shall be at least 0.8 mm and shall be bonded to the aluminium laminate.

6. Inspection and methods of test

6.1 General

For convenience, the properties to be tested, the test category, the test methods and the sub- clause giving the requirements are listed in table 4:

Table 4 —LIST OF TESTS TO BE CONDUCTED

Component(s) Test Property

Test Category

Test method given in Requirement subclause
Conductor Construction

S

ZS 756-1 4.2.1
PVC Insulation Physical properties of material S ZS 756-2 4.2.2
  Thickness S ZS IEC 60811-1-1 4.2.2.2
  Spark test R ZS 764  
  Core identification R, S Visual examination 4.2.3
  Assembly of cores R Visual examination 4.2.4
PVC Sheath Physical properties of material S ZS 756-2 4.2.5.2
  Thickness S ZSIEC 60811-1-1 4.2.5.3
Finished cable Marking R Visual examination 4.2 of ZS 688-1
  Conductor resistance R ZS 756-1 4.3.1
  Voltage withstand R ZS 769-3 4.3.2
  Dielectricresistance S ZS 765 4.3.3
         
NOTE1: In column 3 of this table, a code letter is given that identifies the tests as suitable for use as routine tests (R) or sample tests (S), but compliance with the requirements of the specification may only be fully determined from the results of tests carried out on samples of completed cable(s), using all the test methods given and a sampling procedure agreed upon. During production control, a manufacturer may use any tests that he deems necessary to ensure compliance with the specification but, in the case of a dispute, only the appropriate standard test methods may be used.

NOTE 2: In the administration of the standardisation mark scheme, the frequency of testing required and the tests to be used are the subject of a separate agreement between the Authority administering this standard and the permit holder.

6.2   Conditions of Test

6.2.1   All tests are to be carried out at ambient temperature and pressure, unless otherwise stated in the test method.

6.2.2   Unless otherwise required in the test method, the frequency of the alternating test voltage used shall be approximately 50 Hz, and the waveform shall be substantially sinusoidal.

Table 5 – REQUIREMENTS FOR MULTICORESHEATHEDCABLES (300/500 V)

Number and cross- sectional area of the conductors mm2<FT:Calibri,SN>

Nominal radial thickness of Insulation mm

Nominal radial thickness of sheathb mm

Mean overall dimensions mm (flat cables)<FT:Calibri,SN>

Earth continuity conductor cross-section al Area mm2, min.

Insulation resistance at 23 °C M .km, min.

     

Lower limit

Upper limit

   

2 x a1.0

0.6

0.9

4.0 x 7.2

4.7 x 8.6

1.0a

10

2 x a1.5

0.7

0.9

4.4 x 8.2

5.4 x 9.6

1.0a

10

2 x a2.5

0.8

1

5.2 x 9.8

6.2 x 11.5

1.5a

10

2 x 4.0

0.8

1.1

5.6 x10.5

7.2 x 13.0

1.5a

10

2 x 6.0

0.8

1.1

6.4 x 12.5

8.0 x 15.0

2.5a

10

2 x 10.0

0.9

1.2

7.8 x 15.5

9.6 x 19.0

4

10

2 x 16.0

0.9

1.3

9.0 x 18.0

11.0 x 22.0

6

10

3 x a1.0

0.6

0.9

4.0 x 9.6

4.7 x 11.0

1.0a

10

3 x a1.5

0.7

0.9

4.4 10.5

5.4 x 12.5

1.0a

10

3 x a2.5

0.8

1

5.2 12.5

6.2 x 14.5

1.5a

10

3 x 4.0

0.8

1.1

5.6 x 14.5

7.4 x 18.0

1.5a

10

3 x 6.0

0.8

1.1

6.4 x16.5

8.0 x 20.0

2.5a

10

3 x 10.0

0.9

1.2

7.8 x 21.0

9.6 x 25.5

4.0a

10

   (a)   may be a solid or stranded conductor

   (b)   Sheath thickness for 4 core cables to be same as for 3 core cables

Table 6 – REQUIREMENTS FOR SINGLE CORE UNSHEATHEDPANEL/CUBICLE CABLES (300/500 V)A

Cross- sectional area conductor mm2<FT:Calibri,SN>

Diameter of wire in conductor mm

Approximate diameter of conductor mm

Thickness of insulation mm

Conductor resistance at 20 °C /km, max

Insulation resistance at 23 °C M km, min.

     

Nominal

Min.b<FT:Calibri,SN>

   

Calculated

Nominal

         

0.196

0.5c

0.5

0.5

0.4

89.6

10

0.312

0.63c

0.63

0.5

0.4

56.4

10

0.396

0.71

0.71

0.55

0.45

44.4

10

0.504

0.8

0.8

0.55

0.45

35

10

0.636

0.9

0.9

0.55

0.45

27.6

10

0.785

1

1

0.55

0.45

22.4

10

0.985

1.12

1.12

0.55

0.45

17.9

10

1.227

1.25

1.25

0.55

0.45

14.3

10

1.539

1.4

1.4

0.55

0.45

11.4

10

2.011

1.6

1.6

0.55

0.45

8.75

10

aIn terms of the provisions of ZS 778-1, none of these cables may be used for the wiring of premises.

b This minimum is the nominal less 0.1 mm.

cThese cables are suitable for use in pre-wired and nominally sealed subassemblies and in harnesses

Table 7 — THICKNESSAND INSULATIONRESISTANCEOF PVC INSULATIONOF TYPES D1, D2, D3, D4, D5 ANDD6

Cross- sectional area conductor mm2

Voltage rating
300 / 500 V600 / 1 000 V

Thickness of insulation mm

 

Insulation resistancea at 23 °C M ·km, min

Thickness of insulation mm

 

Insulation resistancea at 23 °C M ·km, min

Nominal

Min

Nominal

Min.

1.0

0.6

0.44

20

0.8

0.62

25

1.5

0.7

0.53

22

0.8

0.62

24

2.5

0.8

0.62

20

0.8

0.62

20

4.0

0.8

0.62

16

1.0

0.80

19

6.0

0.8

0.62

14

1.0

0.80

17

10.0

0.9

0.71

12

1.0

0.80

14

16.0

0.9

0.71

10

1.0

0.80

11

             

a Based on a minimum volume resistivity of 2,0 x 1011 Ù.m at 23 °C and the nominal thickness of the dielectric.

 

PART 3
PVC DISTRIBUTION CABLES

ELECTRIC CABLES WITH EXTRUDEDSOLID DI-ELECTRIC INSULATIONFOR FIXED INSTALLATIONS

(300/500 V TO 1 900/3 300 V) –SPECIFICATION

1. Scope

   1.1   This Part of the Zambian standard ZS 688 specifies the requirements for construction, materials, dimensions and electric properties of single-core and multicore extruded PVC insulated cables of rated operating voltages (U0/ U) 600/1 000 V and 1 900/3 300 V, for use in fixed installations.

   1. 2   Specific types of cables covered by this Part are the following:

   (a)   single and multicore PVC insulated armoured and unarmoured circular cables with protective covering(s); and

   (b)   PVC Insulated earth conductors.

2. Normative references

In this standard, reference has been made to the following standards:

ZS EN 12548, Lead and lead alloys – Lead alloy ingots for electric cable sheathing and for sleeves.

ZS 756-1, Materials of insulated electric cables and flexible cords – Part 1: Conductors.

ZS 756-2, Materials of insulated electric cables and flexible cords – Part 2: Polyvinyl chloride (PVC).

ZS 756-6, Materials of insulated electric cables and flexible cords – Part 6: Armour.

ZS IEC 61034-2, Measurement of smoke density of cables burning under defined conditions – Part 2:

Test procedure and requirements.

ZS IEC 60811-1-1, Common test methods for insulating and sheathing materials of electric cables –Part 1: Methods for general application – Section 1: Measurement of thickness and overall dimensions – Tests for determining the mechanical properties.

ZS 764, Alternating current spark test on electric cables and cords. ZS 765, Dielectric resistance of electric cables ZS 767, ZS 688-1, Electric cables with extruded solid dielectric insulation for fixed installations (300/500 V to 1 900/3 300 V) – Part 1: General.

ZS 767 Acid gas evolved during combustion of cable materials.

ZS 768 Resistance of cables and cords to flame propagation – Bunched cables and cords.

ZS 769-2, Test methods for impregnated paper-insulated electric cables – Part 2: Tests on metallic sheaths.

ZS 769-3, Test methods for cross-linked polyethylene (XLPE) insulated electric cables

– Part 3: Tests on finished cable.

Note

All standards are subject to revision and, since any reference to a standard is deemed to be a reference to the latest edition of that standard, parties to agreements based on this part of ZS 688 are encouraged to take steps to ensure the use of the most recent editions of the standards indicated below. Information on currently valid national and international standards can be obtained from the Zambia Bureau of Standards.

3. Definitions

For the purposes of this Part ofthe Zambia Standard ZS 688, the definitions provided in ZS 688-1shall apply.

4. General requirements

4.1 Cable Operating Voltage

The maximum permissible operating voltage of a cable shall be 600/1 000 V (1.2kV) and 1 900/3 300 V (3.6kV)

4.2 Materials and Construction

4.2.1   Conductors

Conductors shall be manufactured out of plain or tinned annealed copper, or aluminium, as required, and they shall comply with the requirements of ZS 756-1.

4.2.2   Insulation

4.2.2.1   Material

The insulation shall be manufactured out of extruded PVC complying with the requirements for insulation grade PVC of ZS 756-2.

4. 2.2.2   Thickness and insulation resistance

4. 2.2.2.1   The insulation resistance of the insulating material shall meet the requirements stated in table 9, as appropriate to the cross-sectional area of the conductor and operating voltage.

4. 2.2.2.2   When the thickness of the insulation is determined in accordance with ZS IEC 60811-1-1, the average thickness shall at least be equal to the nominal value given in table 9, and the minimum thickness at any point may be less than the nominal value provided that the difference does not exceed 0.1 mm + 10 % of the nominal value.

4. 2.2.3   Spark testing of insulation

Core insulation be continuously spark tested, using the method given in Zambian standard ZS 764 at the appropriate spark test voltage stated in table 1, without breakdown of the dielectric.

Table 1 — SPARK TEST VOLTAGE

Cross-sectional area of the conductor mm2

Alternating current rms test voltage Va

Above

Up to and including

Up to and including cables

1 900/3 300 V cables

16

6 000

12 000

16

240

10 000

12 000

240

12 000

12 000

earth continuity conductor Alternatively, a dc spark test voltage 1,5 times the appropriate ac rms value may be used.

4.2.3   Core identification

4.2.3.1 Identification

Cores shall be identified durably and distinctly by colouring or numbering the insulation as follows:

   (a)   colour coding: where colour coding is used, the cores shall be insulated in the colours stated in table 2.

   (b)   numbering: where numbers are used, the marking shall be in a contrasting colour to that of the insulation, and the interval between any two adjacent numbers or words on the same core shall not exceed 75 mm.

Table 2 — CORE COLOURCODING

Number of phase cores

Colour(s)of phase cores

Colour of neutral core core

Colour of earthing (if present)

1

Red

Black

Green / yellow

2

Red and yellow

Black

Green / yellow

3

Red, yellow and blue

Black

Green / yellow

4 or more

Any base colour except green, with serial numbers (numerals or words)

Numbered as for phase cores

Green / yellow

NOTE:Control cables may have uniquely coloured or numbered cores or both.

4.2.3.2 Colour application

Colour shall be applied—

   (a)   throughout the thickness of the insulation; or

   (b)   on the entire surface of the insulation in a durable manner.

4.2.3.3 Earthing cores

An earthing core shall be coloured green and yellow, and the combination of the colours shall be such that one of the colours covers not less than 30 % and not more than 70 % of the surface of the core, and the other covers the remainder of the surface. There shall be no green/yellow coloured core in a two-core cable or in any non-earthing type cable.

NOTE: The combination of green and yellow is reserved exclusively for the identification of the earthing core.

   4.2.4   Assembly of cores

   4.2.4.1   General

   (a)   The cores of a multicore cable shall be compactly laid up with an acceptable lay and in the correct sequence of their identification colours or numbers.

   (b)   There shall be no turned cores in an assembly of shaped cores.

4.2.4.2 Fillers

Fillers may be applied integrally with the bedding or the sheath, as applicable, and shall be used in the interstices of the cable where necessary to give the completed cable a compact circular cross-section. Filler materials shall be acceptable for the specific type of cable.

4.2.4.3 Binder

A binder may be applied over the laid-up cores, and the material shall be acceptable for the specific type of cable.

4.2.4.4 Concentric conductors

4.2.4.4.1 A concentric conductor shall consist of a single layer of annealed copper wires, which may be tinned, and are applied helically around the laid-up cores with an acceptable lay.

4.2.4.4.2 The concentric conductor shall be separated from the laid-up cores by a separator consisting of a covering of an acceptable material. The separator shall be extruded and may include a binder. It shall be possible to strip the separator from the cores without tearing the dielectric.

4.2.4.4.3 There shall be no sunken or protruding wires and the space between adjacent wires shall not exceed 4 mm. An equalizing member shall be applied. The equalizing member shall consist of one or more annealed copper tapes or wires applied in contact with the concentric conductors and having a suitably short lay. The nominal cross-sectional area of the equalizing member shall be at least 5 % of the area of the concentric conductor to which it is applied and shall be regarded as part of the conducting area.

4.2.4.5 Cross-sectional area of concentric conductors

4.2.4.5.1 The nominal cross-sectional area of a concentric earth continuity conductor (ECC) shall conform to the appropriate value given in table 3.

4.2.4.4.2 The nominal cross-sectional area of a concentric neutral conductor shall—

   (a)   in the case of single-core cables, be at least equal to that of the phase conductor; or

   (b)   in the case of multicore cables, be in accordance with table 3.

Table 3 — SIZES OF CONCENTRICECCS AND NEUTRALCONDUCTORS IN MULTICORECABLES

Cross-sectional area of the Phase conductor 2


mm2

Areas of ECCs and neutral conductors2 mm2

Copper phase conductors

Aluminium phase conductors

ECC

Neutral

ECC

Neutral

1.5

1.0

1.5

2.5

1.5

2.5

4

2.5

4

6

4

6

10

6

10

16

10

16

6

10

25

16

16

6

10

35

16

16

6

10

50

25

25

16

16

70

35

35

25

25

95

50

50

35

35

120

70

70

35

35

150

70

70

50

50

185

95

95

70

70

240

120

120

70

70

300

150

150

95

95

400

185

185

120

120

4.2.5Protective coverings

4.2.5.1 General

Non-metallic coverings shall consist of a continuous extrudate that closely fits but does not adhere to the underlying core or laid-up cores or armour. The surface of the extrudate shall have a smooth finish and its profile shall be uniform and appropriate to the type of cable.

4.2.5.2 Lead or lead alloy sheath

4.2.5.2.1Material

Where a metallic sheath is required it shall be of lead or of lead alloy of type E (see annex B of EN 12548:1999), as required, and when it is tested in accordance with Zambian standard ZS 769-2, the composition shall be as given in the appropriate columns of table 4. Its malleability shall be such that, when the sheath is tested in accordance with Zambian standard ZS 769-2 (belling of sheath), the sheath does not split or crack when the internal diameter of the expanded section reaches 150 % of the original internal diameter.

4.2.5.2.2 Construction:

   (a)   a heat barrier shall be applied over the core assembly before the metallic sheath is applied, and shall consist of one of the following:

   (i)   a layer of tape (cotton, proofed cloth, crêpe paper or compatible synthetic material) applied helically and of total thickness at least 0.3 mm; or   

      (ii)   an under sheath of extruded PVC of nominal thickness at least 1.0 mm.

   (b)   the metallic sheath shall be in the form of a continuous tube that is impervious to moisture, reasonably close fitting and free from defects.

Table 4 — COMPOSITION OF METALLICSHEATH

Element

Content%

 
   

Lead

 

Min.

Max.

Min.

Max.

Antimony

0.15

0.25

0.20

Tin

0.35

0.45

0.10

Copper

0.06

0.06

Bismuth

0.05

0.05

Tellurium

0.005

0.010

Silver

0.005

0.010

Zinc

0.002

0.002

Total other elements+

0.01

0.01

Lead

Remainder

Remainder

99.7

4.2.5.2.3   Thickness

When the thickness of the sheath is determined in accordance with Zambian standard ZS IEC 60811-1-1, it shall be at least equal to the value obtained from the following formula:

t = 0.033 D + 0.7 mm (minimum 1.2 mm)

where -

t is the thickness of sheath, in millimeters; and

D is the calculated diameter over the core or over the laid-up and filled cores, in millimeters. NOTE: Round off the calculated values of the thickness t to the nearest 0.1 mm.

4.2.5.3 Bedding of armoured cable

4.2.5.3.1 Material

Bedding shall consist of a smooth surfaced circular layer of PVC, which shall be either type B or type B1 of Zambian standard ZS 756-2. The bedding shall not adhere to the underlying cores or binder.

4.2.5.3.2 Thickness

   (a)   the nominal and minimum thickness of the bedding shall be as stated in columns 2 and 3 oftable 10 or 11; and

   (b)   when the average thickness of the bedding is determined in accordance with Zambian Sandard ZS IEC 60811-1-1, it shall be at least equal to the nominal value, and the minimum thickness at any point may be less than the nominal value provided that the difference does not exceed 0.1 mm + 15 % of the nominal value.

   4.2.5.4   Armour

When so required, the cable shall be armoured, and the armouring shall meet the following requirements:

   (a)   material: armour shall consist of round wire of galvanized steel or aluminium, as required, and shall comply with Zambian standard ZS 756-6.

   (b)   armouring: the nominal diameter of armour wire shall be as given in table 10 or 11, as relevant. Armour wire shall be applied with an acceptable lay, without any appreciable space between adjacent wires, and there shall be no crossed, riding or protruding wire. Joints in the wire shall be made to an acceptable standard of workmanship without sharp edges or protruding points, and multiple joints shall be acceptably staggered.

   (c)   type of armour wire:

      (i)   for single-core cables, the armour shall be of non-magnetic wire; and

      (ii)   for multicore cables the armour shall be of galvanized steel wire, except as allowed in paragraph (d).<FC:0,112,192>

   (d)   earth continuity conductor: when an improved conductivity in the earth continuity circuit of steel wire armoured multicore cables is required, an appropriate number of steel armour wires may be replaced by tinned hard-drawn copper wires of the same nominal diameter. The copper wires shall comply with the relevant requirements of Zambian Standard ZS 756-1.

The following requirements shall apply:

      (i)   the copper wires shall be of diameter equal to that of the armour, and of number asstated in table 5, appropriate to the cross-sectional area of the conductor; and

      (ii)   the copper wires shall be grouped together and shall not be distributed amongst the armour wires. Where eight or more armour wires are replaced by copper wires, the copper wires shall be arranged in two diametrically opposed groups to allow for a more even distribution of the clamping forces when a mechanical gland is used to terminate the cable.

Table 5 — EARTH CONTINUITYCONDUCTORIN WIRE ARMOUR

Nominal diameter of armour wire mm

Cross-sectional area of the earth conductor mm2

 

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

 

0.9

2

3

4

7

10

17

26

41

57

           

1.25

2

2

3

4

5

9

14

21

30

40

57

1.6

2

2

2

2

3

6

9

13

18

25

35

49

61

76

95

2.0

             

9

12

16

23

31

39

49

61

2.5

               

8

10

15

20

25

31

39

3.15

                   

9

13

16

20

25

Material

Cross-sectional area of the Phase conductor mm2

Copper

1.5

2.5

4

6

10

16

25

50

70

95

120

185

240

300

400

             

35

     

150

       

Aluminium

16

50

70

95

150

185

300

400

         

25

     

120

 

240

       
         

35

                   

4.2.5.5 PVC Outer Sheath

4.2.5.5.1   Material

The sheath shall consist of an extruded layer of PVC, which shall be type S2 ofZambian standardZS 756-2.

   4.2.5.5.2   Thickness

   (a)   the nominal thickness of the sheath shall be as statedin table 6; and

   (b)   when the average thickness of the sheath is determined in accordance with Zambian standard ZS IEC 60811-1-1, it shall be at least equal to the nominal value, and the minimum thickness at any point may be less than the nominal value provided that the difference does not exceed:

      (i)   0.1 mm + 15 % of the nominal value in the case of an unarmoured cable; or   

      (ii)   0.2 mm + 20 % of the nominal value in the case of an armoured cable

Table 6 — THICKNESSOF OUTER SHEATH

4

Nominal diameter under sheat mm

Thickness of sheath mm

   

Unarmoured cable

Armoured cable

       

Without lead sheath

With lead sheath

   

Nominal

Min.

Nominal

Min.

Nominal

Min.

 

<< 10

1.6

1.26

1.4

0.92

1.6

1.08

>10

<< 15

1.8

1.43

1.5

1.00

1.6

1.08

>15

<< 20

1.8

1.43

1.6

1.08

1.6

1.08

>20

<< 25

2.0

1.60

1.7

1.16

1.8

1.24

>25

<< 30

2.0

1.60

1.8

1.24

2.0

1.40

>30

<< 35

2.2

1.77

2.0

1.40

2.2

1.56

>35

<< 40

2.2

1.77

2.2

1.56

2.4

1.72

>40

<< 45

2.4

1.94

2.4

1.72

2.6

1.88

>45

<< 50

2.6

2.11

2.4

1.72

2.8

2.04

>50

<< 55

2.8

2.28

2.6

1.88

3.0

2.20

>55

<< 60

3.0

2.45

2.8

2.04

3.0

2.20

 

>60

3.4

2.79

3.0

2.20

3.0

2.20

4.3Electrical Requirements for Finished Cables

4.3.1Conductor resistance

The dc resistance of each conductor shall not exceed the appropriate maximum value given in Zambian standard ZS 756-1

4.3.2Voltage withstand

When a cable is factory tested in accordance with Zambian standardZS 769-3, each core of the cable shall withstand, for 10 minutes without breakdown of the dielectric, a test voltage of the appropriate value given in column 3 or 4 of table 7. Alternatively, the test may be conducted for 5 minutes at a test voltage of the appropriate value stated in column 5 or 6 of the table.

Table 7 — TEST VOLTAGES

Cables

Alternating current rms test voltage Vat 50Hz

Rated voltage V

Type or cross-sectional area

10 minute test

 

5 minute test

   

Betweenconductors

Between any conductor and earth

Between conductors Between any conductor and earth

600 / 1 000

2

 

2 000

3 0003 000

600 / 1 000

Cables of cross sectional area 25 mm2and above

 

3 000

4 5004 500

1 900/3300

Cables of all sizes

6 700

3 900

10 0005 800

4.3.3Di-electric resistance

When a cable is tested in accordance with Zambian Standard ZS 765, the insulation resistance of the cable shall be at least equal to the value given in the appropriate columns of table 9.

4.4Additional Requirements for Fire Retardant Cable

4.4.1Reduced flame propagation

When a cable that is required to have reduced flame propagation properties is tested in accordance with Zambian Standard ZS 768, the height of the charred or affected portion above the bottom edge of the burner shall not exceed 2.5 m (see also B.3 of annex B of ZS 688-1).

4.4.2Reduced smoke emission

When a cable that is required to have reduced smoke emission properties is tested in accordance with Zambian Standard ZS IEC 61034-2, the light transmittance shall exceed the following values throughout the test:

Number of specimens of cable tested

Light transmittance

4

50 %

3

60 %

2

60 %

1

70 %

4.4.3Reduced halogen emission

When a cable that is required to have reduced halogen emission properties is tested in accordance with Zambian standardZS 767, the evolution of halogen gas from the bedding and sheathing obtained from the finished cable shall not exceed 150 mg/g (15 % (m/m)).

5. Inspection and methods of test

5.1General

For convenience, the properties to be tested, the test category, the test methods and the sub-clause giving the requirements are listed in table 8:

Table 8 — LIST OF TESTS TO BE CONDUCTED

5

Component(s)

Test property

Test category

Test method given in

Requirement subclause

Conductor

Construction

S

ZS 756-1

4.2.1

PVC Insulation

Physical

     
 

properties

S

ZS 756-2

4.2.2.1

 

Thickness

S

ZS IEC 60811-1-1

4.2.2.2

 

Spark test

R

ZS 764

4.2.2.3

 

Core identification

R,S

Visual examination

4.2.3

 

Assembly of cores

R

Visual examination

4.2.4

PVC Bedding

Physical

S

ZS 756-2

4.2.5.3

 

properties

     
 

Thickness

S

ZS IEC 60811-1-1

4.2.5.3

 

Halogen

T

ZS 767

4.4.3

Lead sheath

Construction

S

ZS 769-2

4.2.5.2

 

Belling

S

ZS 769-2

4.2.5.2

 

Thickness

S

ZS IEC 60811-1-1

4.2.5.2 (c)

Armour

Amour

     
 

Wire diameter

S

ZS 756-6

4.2.5.4

 

Mass of Zinc

     
 

coating

S

ZS 756-6

 
 

Adhesion of Zinc

     
 

coating

S

ZS 756-6

 
 

Tensile strength

S

ZS 756-6

 
 

Elongation at break

S

ZS 756-6

 

PVC Outer

Physical

     

Sheath

properties

S

ZS 756-2

4.2.5.5

 

Thickness

S

ZS IEC 60811-1-1

4.2.5.5

 

Halogen

T

ZS 767

4.4.3

Finished cable

Marking

R

Visual examination

ZS 688-1: 4.2.1

 

Conductor

     
 

resistance

R

ZS 756-1

4.3.1

 

Voltage withstand

R

ZS 769-3

4.3.2

 

Dielectric resistance

S

ZS 765

4.3.3

 

Fire propagation

T

ZS 768

4.4.1

 

Smoke emission

T

ZS IEC 61034-2

4.4.2

Note 1: In column 3 of this table, a code letter is given that identifies the tests as suitable for use as routine tests (R), sample tests (S) or type tests (T), but compliance with the requirements of the specification may only be fully determined from the results of tests carried out on samples of completed cable(s), using all the test methods given and a sampling procedure agreed upon During production control, a manufacturer may use any tests considered necessary to ensure compliance with the specification but, in the case of a dispute, only the appropriate standard test methods may be used.

Note 2: In the administration of the standardization mark scheme, the frequency of testing required and the tests to be used are the subject of a separate agreement between the Authority administering this standard and the permit holder.

5.2Conditions of Test

5.2.1   All tests are to be carried out at ambient temperature and pressure, unless otherwise stated in the test method.

5.2.2   Unless otherwise required in the test method, the frequency of the alternating test voltage used shall be approximately 50 Hz, and the waveform shall be substantially sinusoidal.

Table 9 — THICKNESSAND INSULATIONRESISTANCEOF PVC INSULATIONOF TYPES D1, D2, D3, D4, D5 ANDD6

Cross- sectional area of the conductor mm2

Voltage rating

600/I 000 V

   

1900/3 300 V

Thickness of insulation mm

Insulation resistanceaat 23 °C MU-km, man

Thickness of insulation mm

Insulation resistanceaat 23 °C MU-km, min.

Nominal

Min.

Nominal

Min.

1.0

0.8

0.62

25

1.5

0.8

0.62

24

2.5

0.8

0.62

20

4

1.0

0.80

19

6

1.0

0.80

17

10

1.0

0.80

14

2.2

1.88

25

16

1.0

0.80

11

2.2

1.88

21

25

1.2

0.98

11

2.2

1.88

18

35

1.2

0.98

9

2.2

1.88

16

50

1.4

1.16

9

2.2

1.88

14

70

1.4

1.16

8

2.2

1.88

12

90

1.6

1.34

8

2.2

1.88

10

120

1.6

1.34

7

2.2

1.88

9

150

1.8

1.52

7

2.2

1.88

8

185

2.0

1.70

7

2.2

1.88

8

240

2.2

1.88

7

2.2

1.88

7

280

2.3

1.97

7

2.3

1.97

7

300

2.4

2.06

7

2.4

2.06

7

380

2.5

2.15

6

2.5

2.15

6

400

2.6

2.24

6

2.6

2.24

6

480

2.7

2.33

6

2.7

2.33

6

500

2.8

2.42

6

2.8

2.42

6

600

2.8

2.42

5

2.8

2.42

5

630

2.8

2.42

5

2.8

2.42

5

740

2.8

2.42

5

2.8

2.42

5

800

2.8

2.42

5

2.8

2.42

5

900

2.9

2.51

4

2.9

2.51

4

1000

3.0

2.60

4

3.0

2.60

4

1200

3.2

2.78

4

3.2

2.78

4

a Based on a minimum volume resistivity of 2.0 x 1011 U.m at 23 °C and the nominal thickness of the dielectric.

NOTE : For insulated earth conductors exceeding 16 mm2 the nominal thickness shall be at least 1.0 mm and the minimum thickness shall be 0.8 mm.

Table 10 — BEDDING THICKNESSAND ARMOUR WIRE DIAMETEROF CABLES WITHOUT LEAD SHEATH

Nominal diameter over core or laid up cores mm

Thickness of extruded bedding mm

Nominal a
diameter of armour wire

   

Nominal

Min.

mm

 

<< 10

0.8

0.58

b0.9

>10

<< 15

0.8

0.58

b0.9

>15

<< 20

1.2

0.92

c1.60

>20

<< 25

1.2

0.92

1.60

>25

<< 35

1.4

1.09

2.0

>35

<< 55

1.6

1.26

2.5

>45

<< 60

1.6

1.26

2.5

 

>60

1.6

1.26

3.15

aLarger diameter wires may be used if agreed with the purchaser.

bArmour wires may be of diameter 0.9 mm or 1.25 mm.

cArmour wires may be of diameter 1.25 mm or 1.60 mm.

Table 11— BEDDING THICKNESSAND ARMOUR WIRE DIAMETEROF CABLES WITH LEAD SHEATH

Nominal diameter over core or laid up cores mm

Thickness of extruded bedding mm

Nominal diameter of armour wirea

Nominal

Min.

mm

<< 20

1.4

1.09

1.6

>20 << 25

1.6

1.26

2.0

>25 << 30

2.0

1.60

2.0

>30 << 40

2.2

1.77

2.0

>40 << 45

2.4

1.94

2.5

>45 << 50

2.4

1.94

2.5

>50 << 60

2.6

2.11

3.15

>60

2.6

2.11

3.15

aLarger diameter wires may be used if agreed with the purchaser.

 

PART 4
XLPE DISTRIBUTION CABLES

ELECTRIC CABLES WITH EXTRUDEDSOLID DI-ELECTRIC INSULATIONFOR FIXED INSTALLATIONS

(300/500V TO 1900/3 300 V—SPECIFICATION

1. Scope

1.1   This Part of the Zambian Standard ZS 688 specifies the requirements for construction, materials, dimensions and electric properties of multicore extruded XLPE insulated cables of rated operating voltages (U0/ U) 600/1 000 V and 1 900/3 300 V, for use in fixed installations.

1. 2 Specific types of cables covered by this Part are multicore XLPE insulated armoured and unarmoured circular cables with protective covering(s).

2. Normative references

In this standard, reference has been made to the following standards:

ZS 756-1, Materials of insulated electric cables and flexible cords – Part 1: Conductors; ZS 756-2, Materials of insulated electric cables and flexible cords – Part 2: Polyvinyl chloride (PVC);

ZS 756-3, Materials of insulated electric cables and flexible cords – Part 3: Elastomers; ZS 756-4, Materials of insulated electric cables and flexible cords – Part 4: Cross-linked polyethylene (XLPE);

ZS 756-5, Materials of insulated electric cables and flexible cords – Part 5: Halogen- free, flame-retardant materials;

ZS 756-6, Materials of insulated electric cables and flexible cords – Part 6: Armour; and

ZS 756-7, Materials of insulated electric cables and flexible cords – Part 7: Polyethylene (PE). ZS 771, The preservative treatment of timber.

NOTE:

All standards are subject to revision and, since any reference to a standard is treated as a reference to the latest edition of that standard, parties to agreements based on this part of ZS 688 are encouraged to take steps to ensure the use of the most recent editions of the standards indicated. Information on currently valid national and international standards can be obtained from the Zambia Bureau of Standards.

3. Definitions

For the purposes of this Part of Zambian standard ZS 688 the definitions given in Zambian Standard ZS 688-1 shall apply.

4. Requirements

4.1   Cable Operating Voltage

The maximum permissible operating voltage of a cable shall be 600/1 000 V or 1 900/3 300 V.

4.2 Materials and Construction

4.2.1   Conductors

Conductors shall be manufactured from annealed copper, or aluminium, as required, and shall comply with the requirements of Zambian standardZS 756-1.

4.2.2   Insulation

4.2.2.1 Material

The insulation shall be of extruded XLPE of the type A or B of ZS 756-4, as required, and shall comply with the requirements of Zambian standard ZS 756-4.

4.2.2.2 Thickness and insulation resistance

4.2.2.2.1The insulation resistance of the insulating material shall comply with the requirements stated in table 9, as appropriate to the cross-sectional area of the conductor and operating voltage.

4.2.2.2.2When the thickness of the insulation is determined in accordance with Zambian standard ZS IEC 60811-1-1, the average thickness shall be at least equal to the nominal value stated in table 9, and the minimum thickness at any point may be less than the nominal value provided that the difference does not exceed 0.1 mm + 10 % of the nominal value.

4.2.2.3 Spark testing of insulation

Core insulation shall be continuously spark tested, using the method given in SABS SM 524 at the appropriate spark test voltage stated in table 1, without breakdown of the dielectric.

Table 1— SPARK TEST VOLTAGE

Cross-sectional area of the conductormm2

Alternating current rms test voltage Vs

Above

Up to and including

600/1 000 V cables

1 900/3 300 V cables

6 000

12 000

16

16

10 000

12 000

240

240

12 000

12 000

’Alternatively, a dc spark test voltage 1.5 times the appropriate ac rms value may be used.

4.2.3Core identification

4.2.3.1 Identification

Cores shall be identified durably and distinctly by the colouring or numbering of the insulation.

   (a)   Colour coding: Where colour coding is used, the cores shall be insulated in the colours in table 2.

   (b)   Numbering: Where numbers are used, the marking shall be in a contrasting colour to that of the insulation, and the interval between any two adjacent numbers or words on the same core shall not exceed 75 mm.

Table 2 — CORE INSULATIONCOLOURCODING

Number of phase cores

Colour(s)of phase cores

Colour of neutral core

Colour of earthing core(if present and not bare)

1

Red

Black

Green / yellow

2

Red and yellow

Black

Green/yellow

3

Red, yellow and blue

Black

Green/yellow

4   or more

Any base colour except green, with serial numbers (numerals or words)

Numbered as for phase cores

Green/yellow

Note Control cables may have uniquely coloured or numbered cores or both.

4.2.3.2 Colour application

Colour shall be applied —

   (a)   throughout the thickness of the insulation; or

   (b)   in a durable manner on the entire surface of the insulation.

4.2.3.3 Earthing cores

Where an earthing core is not bare, it shall be coloured green and yellow, and the combination of the colours shall be such that one colour shall cover not less than 30 % and not more than 70 % of the surface of the core, and the other cover the remainder of the surface. There shall be no green and yellow coloured core in a two-core cable or in any non-earthing type cable.

NOTE

The combination of green / yellow is reserved exclusively for the identification of the earthing core.

4.2.4Assembly of cores

4.2.4.1 General

4.2.4.1.1The cores shall be compactly laid up with an acceptable lay and in the correct sequence of their identification colours or numbers.

4.2.4.1.2There shall be no turned cores in an assembly of shaped cores.

4.2.4.2 Fillers

Fillers may be applied integrally with the bedding or the sheath, as applicable, and shall be used in the interstices of the cable where necessary to give the completed cable a compact circular cross-section. Filler materials shall be acceptable for the specific type of cable.

4.2.4.3 Binder

A binder may be applied over the laid-up cores, and the material shall be acceptable for the specific type of cable.

4.2.4.4 Concentric conductors

4.2.4.4.1A concentric conductor shall consist of a single layer of annealed copper wires, which may be tinned, and applied helically around the laid-up cores with an acceptable lay.

4.2.4.4.2The concentric conductor shall be separated from the laid-up cores by a separator consisting of a covering of an acceptable material. The separator shall be extruded and may include a binder. It shall be possible to strip the separator from the cores without tearing the dielectric.

4.2.4.4.3There shall be no sunken or protruding wires and the space between adjacent wires shall not exceed 4 mm. An equalising member shall be applied. The equalising member shall consist of one or more annealed copper tapes or wires applied in contact with the concentric conductors and having a suitably short lay. The nominal cross-sectional area of the equalising member shall be at least 5 % of the area of the concentric conductor to which it is applied and shall be regarded as part of the conducting area.

4.2.4.5 Cross-sectional area of concentric conductors

4.2.4.5.1The nominal cross-sectional area of a concentric earth continuity conductor (ECC) shall conform to the appropriate value given in table 3.

4.2.4.5.2The nominal cross-sectional area of a concentric neutral conductor shall -

   (a)   in the case of single-core cables, be at least equal to that of the phase conductor; or

   (b)   in the case of multicore cables, be in accordance with table 3.

Table 3 – CROSS-SECTIONAL AREA OF THE CONCENTRICECCS AND NEUTRAL CONDUCTORS IN MULTICORECABLES

Cross-sectional area of the phase conductor mm2

mm2

 

Copper phase conductors

Aluminium phase conductors

 

ecc (copper)

Neutral (copper)

ecc (copper)

Neutral (copper)

1.5

1.0

1.5

 

1.5

2.5

4

2.5

4

6

4

6

 

6

10

16

10

16

6

10

25

16

16

6

10

35

16

16

6

10

50

25

25

16

16

70

35

35

25

25

95

50

50

35

35

120

70

70

35

35

150

70

70

50

50

185

95

95

70

70

240

120

120

70

70

300

150

150

95

95

400

185

185

120

120

4.2.5Protective coverings

4.2.5.1 General

Non-metallic coverings shall consist of a continuous extrudate that closely fits but does not adhere to the underlying core or laid-up cores or armour. The surface of the extrudate shall have a smooth finish and its profile shall be uniform and appropriate to the type of cable.

4.2.5.2 Lead or lead alloy sheath

4.2.5.2.1 Material

Where a metallic sheath is required it shall be of lead or of lead alloy of type E (see annex B of EN 12548:1999), as required, and when it is tested in accordance with SABS SM 1281-2, the composition shall be as given in the appropriate columns of table 4. Its malleability shall be such that, when the sheath is tested in accordance with SABS SM 1281-2, the sheath does not split or crack when the internal diameter of the expanded section reaches 150 % of the original internal diameter.

4.2.5.2.2 Construction:

   (a)   a heat barrier shall be applied over the core assembly before the metallic sheath is applied, and shall consist of one of the following:

      (i)    a layer of tape (cotton, proofed cloth, crêpe paper or compatible synthetic material) applied helically and of total thickness of at least 0.3 mm; or

      (ii)    a bedding in accordance with 4.2.5.3, except that the nominal thickness shall be 1.0 mm.

   (b)   the metallic sheath shall be in the form of a continuous tube that is impervious to moisture, reasonably close fitting and free from defects.

Table 4 – COMPOSITION OF METALLICSHEATH

Element

Content%

 

Lead alloy Ea

Lead

 

Max.

Min.

Max.

Antimony

0.15

0.25

0.20

Tin

0.35

0.45

0.10

Copper

0.06

0.06

Bismuth

0.05

0.05

Tellurium

0.005

0.010

Silver

0.005

0.010

Zinc

0.002

0.002

Total other elementsb

0.01

0.01

Lead

Remain

Remain

99.7

 

aLead alloy E is recommended for installations subject to vibration.

bAll elements other than those specified in the table.

   4.2.5.2.2 Thickness

When the thickness of the sheath is determined in accordance with Zambian Standard ZS IEC 60811-1-1, it shall be at least equal to the value obtained from the following formula:

t = 0.033 D + 0.7 mm (minimum 1.2 mm)

where—

t is the thickness of sheath, in millimeters; and

D is the calculated diameter over the core or over the laid-up and filled cores, in millimeters

NOTE: Round off the calculated values of the thickness to the nearest 0.1 mm.

4.2.5.3 Bedding of armoured cable

4.2.5.3.1 Material

Bedding shall consist of a smooth surfaced, circular layer of PVC type B1 of Zambian StandardZS 756-2. A full cover separating tape shall be applied over the cores under the bedding. The bedding shall not adhere to the underlying cores or binder.

4.2.5.3.2 Thickness

   (a)   Unless otherwise stated, the nominal and minimum thickness of the bedding shall be as given in columns 2 and 3 of table 10 or 11, as appropriate.

   (b)   When the average thickness of the bedding is determined in accordance with ZS IEC 60811-1-1, it shall be at least equal to the nominal value, and the minimum thickness at any point may be less than the nominal value provided that the difference does not exceed 0.1 mm + 15 % of the nominal value.

4.2.5.4 Armour

When so required, the cable shall be armoured, and the armouring shall comply with the following:

   (a)   material: Armour shall consist of round wire of galvanized steel, which shall comply with Zambian Standard ZS 756-6;

   (b)   armouring: the nominal diameter of armour wire shall be as given in column 4 of table 10 or 11, as relevant. Armour wire shall be applied with an acceptable lay, without any appreciable space between adjacent wires, and there shall be no crossed, riding or protruding wire. Joints in the wire shall be made in an acceptable workmanlike manner without sharp edges or protruding points, and multiple joints shall be acceptably staggered.

   (c)   earth continuity conductor: When an improved conductivity in the earth continuity circuit of steel wire armoured multicore cables is required, an appropriate number of steel wires may be replaced by tinned hard-drawn copper wires of the same nominal diameter. The copper wires shall comply with the relevant requirements of Zambian StandardZS 756-1.

The following requirements shall apply:

      (i)   the copper wires shall be of diameter equal to that of the armour, and of number as given in table 5, appropriate to the cross-sectional area of the conductor; and   

      (ii)   the copper wires shall be grouped together and shall not be distributed amongst the armour wires. Where eight or more armour wires are replaced by copper wires, the copper wires shall be arranged in two diametrically opposed groups to allow for a more even distribution of the clamping forces when a mechanical gland is used to terminate the cable.

Table 5 — EARTH CONTINUITYCONDUCTORIN WIRE ARMOUR

Nominal diameter of armour wire mm

Cross-sectional area of the earth conductor mm2

 

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

 

Number ofearth continuity conductor wires

0.9

2

3

4

7

10

17

26

41

57

           

1.25

2

2

3

4

5

9

14

21

30

40

57

1.6

2

2

2

2

3

6

9

13

18

25

35

49

61

76

95

2.0

             

9

12

16

23

31

39

49

61

2.5

               

8

10

15

20

25

31

39

3.15

                   

9

13

16

20

25

Material

Cross-sectional area of the Phase conductor mm2

Copper

1.5

2.5

4

6

10

16

25

50

70

95

120

185

240

300

400

             

35

     

150

       

Aluminium

       

16

 

50

70

95

150

185

300

400

   
         

25

     

120

 

240

       
         

35

                   

4.2.5.5 Outer Sheath

4.2.5.5.1Material:

The sheath shall consist of either PVC type S2 of Zambian StandardZS 756-2 or polyethylene type PS1 or PS2 of ZS 756-7.

4.2.5.5.2 Thickness:

   (a)   the nominal thickness of the sheath shall be as given in table 6; and

   (b)   when the average thickness of the sheath is determined in accordance with Zambian Standard ZS IEC 60811—1, it shall be at least equal to the nominal value, and the minimum thickness at any point may be less than the nominal value provided that the difference does not exceed:

      (i)   0.1 mm + 15 % of the nominal value in the case of an unarmoured cable; or

      (ii)   0.2 mm + 20 % of the nominal value in the case of an armoured cable

Table 6 — THICKNESSOF OUTER SHEATH

Nominal
diameter

Thickness of sheath mm

under sheat

           

mm

 

Unarmoured cable

 

Armoured cable

 
       

Without lead sheath

With lead sheath

   

Nominal

Min.

Nominal

Min.

Nominal

Min.

 

<< 10

1.6

1.26

1.4

0.92

1.6

1.08

>10

<< 15

1.8

1.43

1.5

1.00

1.6

1.08

>15

<< 20

1.8

1.43

1.6

1.08

1.6

1.08

>20

<< 25

2.0

1.60

1.7

1.16

1.8

1.24

>25

<< 30

2.0

1.60

1.8

1.24

2.0

1.40

>30

<< 35

2.2

1.77

2.0

1.40

2.2

1.56

>35

<< 40

2.2

1.77

2.2

1.56

2.4

1.72

>40

<< 45

2.4

1.94

2.4

1.72

2.6

1.88

>45

<< 50

2.6

2.11

2.4

1.72

2.8

2.04

>50

<< 55

2.8

2.28

2.6

1.88

3.0

2.20

>55

<< 60

3.0

2.45

2.8

2.04

3.0

2.20

 

>60

3.4

2.79

3.0

2.20

3.0

2.20

   4.3Electrical Requirements for Finished Cables

   4.3.1Conductor resistance

The dc resistance of each conductor shall not exceed the appropriate maximum value given in Zambian standard ZS 756-1.

   4.3.2Voltage withstand

When a cable is factory tested in accordance with Zambian standard ZS 769, each core of the cable shall withstand, for 10 min without breakdown of the dielectric, a test voltage of the appropriate value given in column 3 or 4 of table 7. Alternatively, the test may be conducted for 5 min at a test voltage of the appropriate value given in column 5 or 6 of the table.

Table 7 — Test Voltages

Cables

Alternating current rms test voltage V

Rated

Type or cross-

10 minute test

5 minute test

voltage V

sectional area

Between conductors

Between any conductor and earth

Between conductors

Between any conductor and earth

600 / 1 000

Cables of cross sectional areanot exceeding 16 mm2

2 000

2 000

3 000

3 000

600 / 1 000

Cables of cross sectional area 25 mm2and above

3 000

3 000

4 500

4 500

1 900 / 3 300

Cables of all sizes

6 700

3 900

10 000

5 800

   4.3.3Di-electric resistance

When a cable is tested in accordance with Zambian StandardZS 765, the insulation resistance of the cable shall be at least 100 MÙ km at 23 ºC.

   4.4Additional Requirements for Fire Retardant Cables

   4.4.1Reduced flame propagation

When a cable that is required to have reduced flame propagation properties is tested in accordance with Zambian Standard ZS 768, the height of the charred or affected portion above the bottom edge of the burner shall not exceed 2.5 m. (See also B.3 of ZS 688-1).

4. 4.2Reduced smoke emission

When a cable that is required to have reduced smoke emission properties is tested in accordance with Zambian standard ZS 767, the light transmittance shall exceed the following values throughout the test:

Number of specimens of cable testedLight Transmittance

450 %

360 %

260 %

170 %

4.4.3Reduced halogen emission

When a cable that is required to have reduced halogen emission properties is tested in accordance with Zambian standardZS 767, the evolution of halogen gas from the bedding and sheathing obtained from the finished cable shall not exceed 150 mg/g (15 % (m/m)).

4.5Compatibility of Compounds

Cable materials that are intended to be in contact with one another shall be compatible. Where the cable construction is such that PVC and other compounds are used in the same cable, the compounds shall be separated by a compatible barrier tape, or the PVC compound shall be so modified as to prevent any plasticizer migration. Plasticizer migration can lead to reduction or loss of desired properties of the other components.

5. Specific requirements for types of cable in common use

   5.1 Aluminium Laminate Sheathed Cables (1 900/3 300 V)

   5.1.1   Cables shall have 2 or 3 cores, coloured as stated in table 2, with a bare earth continuity conductor. The earth continuity conductor shall be tinned annealed copper and shall comply with the requirements given in table 3.

   5.1.2   Aluminium laminate shall consist of longitudinally applied aluminium tape of minimum thickness 0.1 mm, covered by the outer sheath (see (c)). The aluminium tape shall be laminated with a material suitable for bonding with the outer sheath, and shall be in close contact with the bare earth.

   5.1.3   The sheath shall consist of UV stabilized polyethylene type PS1 or PS2 of Zambian standard ZS 756-7, and shall be bonded to the aluminium laminate.

6. Inspection and methods of test

   6.1General

For convenience, the properties to be tested, the test category, the test methods and the sub-clause giving the requirements are listed in table 8:

Table 8 — LIST OF TESTS TO BE CONDUCTED

Component(s)

Test property

Test category

Test method given in

Requirement subclause

Conductor insulation

Construction

S

ZS 756-1

4.2.1

 

Physical

     
 

properties

S

ZS 756-2

4.2.2.1

 

Thickness

S

ZS IEC 60811-1-1

4.2.2.2

 

Spark test

R

ZS 764

4.2.2.3

 

Core identification

R,S

Visual examination

4.2.3

 

Assembly of cores

R

Visual examination

4.2.4

Bedding

Physical properties

S

ZS 756-2

4.2.5.3

 

Thickness

S

ZS IEC 60811-1-1

4.2.5.3

 

Halogen

T

ZS 767

4.4.3

Lead sheath

Construction

S

ZS 769-2

4.2.5.2

 

Belling

S

ZS 769-2

4.2.5.2

 

Thickness

S

ZS IEC 60811-1-1

4.2.5.2 (c)

Armour

Amour

     
 

Wire diameter

S

ZS 756-6

4.2.5.4

 

Mass of Zinc

     
 

coating

S

ZS 756-6

 
 

Adhesion of Zinc

     
 

coating

S

ZS 756-6

 
 

Tensile strength

S

ZS 756-6

 
 

Elongation at break

S

ZS 756-6

 
 

Physical

     

Sheath

properties

S

ZS 756-2

4.2.5.5

 

Thickness

S

ZS IEC 60811-1-1

4.2.5.5

 

Halogen gas

T

ZS 767

4.4.3

Finished cable

Marking

R

Visual examination

SABS1507-1 4.2.1

 

Conductor resistance

R

ZS 756-1

4.3.1

 

Voltage withstand

R

ZS 769-3

4.3.2

 

Dielectric resistance

S

ZS 765

4.3.3

 

Fire propagation

T

ZS 768

4.4.1

 

Smoke emission

T

ZS 767

4.4.2

NOTE 1: In column 3 of this table, a code letter is given that identifies the tests as suitable for use as routine tests (R), sample tests (S) or type tests (T), but compliance with the requirements of the specification may only be fully determined from the results of tests carried out on samples of completed cable(s), using all the test methods given and a sampling procedure agreed upon. During production control, a manufacturer may use any tests considered necessary to ensure compliance with the specification but, in the case of a dispute, only the appropriate standard test methods may be used.

NOTE2: In the administration of the standardization mark scheme, the frequency of testing required and the tests to be used are the subject of a separate agreement between the Authority administering this standard and the permit holder.

   6.2Conditions of Test

   6.2.1   All tests are to be carried out at ambient temperature and pressure, unless otherwise stated in the test method.

   6.2.2   Unless otherwise required in the test method, the frequency of the alternating test voltage used shall be approximately 50 Hz, and the waveform shall be substantially sinusoidal.

Table 9 — THICKNESS OF XLPE INSULATION

Cross-sectional area of the conductor mm2

Voltage rating

 

1 900/3 300 V

 

Thickness of insulation mm

 

Min.

Nominal

Min.

1.0

0.7

0.53

1.5

0.7

0.53

2.5

0.7

0.53

4

0.7

0.53

6

0.7

0.53

10

0.7

0.53

2.0

1.70

16

0.7

0.53

2.0

1.70

25

0.9

0.71

2.0

1.70

35

0.9

0.71

2.0

1.70

50

1.0

0.80

2.0

1.70

70

1.1

0.89

2.0

1.70

95

1.1

0.89

2.0

1.70

120

1.2

0.98

2.0

1.70

150

1.4

1.16

2.0

1.70

185

1.6

1.34

2.0

1.70

240

1.7

1.43

2.0

1.70

280

1.8

1.52

2.0

1.70

300

1.8

1.52

2.0

1.70

380

2.0

1.70

2.0

1.70

400

2.0

1.70

2.0

1.70

480

2.2

1.88

2.2

1.88

500

2.2

1.88

2.2

1.88

600

2.4

2.06

2.4

2.06

630

2.4

2.06

2.4

2.06

740

2.5

2.15

2.5

2.15

800

2.6

2.24

2.6

2.24

960

2.7

2.33

2.7

2.33

1000

2.8

2.42

2.9

2.42

1200

2.9

2.51

2.9

2.51

Table 10 — BEDDING THICKNESSAND ARMOUR WIRE DIAMETEROF CABLES WITHOUTLEAD SHEATH

Nominal diameter over core or laid up cores mm

Thickness of extruded bedding m m

Nominal adiameter of armour wire mm


b

 

Nominal

Min.

 

<< 10

0.8

0.58

0.9

>10 << 15

0.8

0.58

b0.9

>15 << 20

1.2

0.92

c1.60

>20 << 25

1.2

0.92

1.60

>25 << 35

1.4

1.09

2.0

>35 << 55

1.6

1.26

2.5

>45 << 60

1.6

1.26

2.5

>60

1.6

1.26

3.15

aLarger diameter wires m bArmour wires may be of cArmour wires may be

b Armour wires may be of diameter 0.9 mm or 1.25 mm.

c Armour wires may be of diameter 1.25 mm or 1.60 mm.

Table 11 — BEDDING THICKNESSAND ARMOUR WIRE DIAMETEROF CABLES WITH LEAD SHEATH

Nominal diameter over core or laid up cores
mm
Thickness ofextruded bedding mm Nominal diameter of armour wirea
mm
Nominal Min.

<< 20

1.4

1.09

1.6

>20 << 25

1.6

1.26

2.0

>25 << 30

2.0

1.60

2.0

>30 << 40

2.2

1.77

2.0

>40 << 45

2.4

1.94

2.5

>45 << 50

2.4

1.94

2.5

>50 << 60

2.6

2.11

3.15

>60

2.6

2.11

3.15

a Larger diameter wires may be used if agreed with the purchaser

 

PART 5
HALOGEN-FREE DISTRIBUTION CABLES SPECIFICATION

ELECTRIC CABLES WITH EXTRUDEDSOLID DI-ELECTRICINSULATIONFOR FIXED INSTALLATIONS

(300/500 V TO 1 900/3 300 V)

1. Scope

1.1   This Part of Zambian Standard ZS 688 covers the requirements for construction, materials, dimensions and electric properties of single-core and multicore halogen-free cables of rated operating voltages (U /U) 600/1 000 V to 1 900/3 300 V, for use in fixed installations.

1.2 Specific types of cables covered by this Part of Zambian standard ZS 688 are single and multicore insulated armoured and unarmoured circular cables with protective covering(s). The cables are also flame retardant, and emit no halogen gases and little smoke under exposure to fire.

2. Normative references

In this standard, reference has been made to the following standards:

ZS EN 12548 Lead and lead alloys – Lead alloy ingots for electric cable sheathing and for sleeves;

ZS 756-1 Materials of insulated electric cables and flexible cords – Part 1: Conductors; ZS 756-4 Materials of insulated electric cables and flexible cords – Part 4: Cross-linked polyethylene (XLPE);

ZS 756-5 Materials of insulated electric cables and flexible cords – Part 5: Halogen-free flame retardant materials;

ZS 756-6 Materials of insulated electric cables and flexible cords - Part 6: Armour;

ZS 688-1 Electric cables with extruded solid dielectric insulation for fixed installations (300/500 V to 1 900/3 300 V) – Part 1: General;

ZS IEC 60811-1-1 Common test methods for insulating and sheathing materials of electric and optical cables – Part 1-1: Methods for general application – Measurement of thickness and overall dimensions – Tests for determining the mechanical properties;

ZS IEC 61034-2 Measurement of smoke density of cables burning under fire conditions – Part 2: Test procedure and requirements;

ZS 764 Alternating current spark test on electric cables and cords; ZS 765 Dielectric resistance of electric cables;

ZS 767 Acid gas evolved during combustion of cable materials;

ZS 768 Resistance of cables and cords to flame propagation – Bunched cables and cords;

ZS 769-2 test methods for impregnated paper-insulated electric cables – Part 2: Tests on metallic sheaths; and

ZS 769-3 test methods for cross-linked polyethylene (XLPE) insulated electric cables – Part 3: Tests on finished cable.

NOTE

All standards are subject to revision and, since any reference to a standard is treated as a reference to the latest edition of that standard, parties to agreements based on this Part of Zambian standard ZS 688 are encouraged to take steps to ensure the use of the most recent editions of the standards indicated. Information on currently valid national and international standards can be obtained from the Zambia Bureau of Standards.

3. Definitions

For the purposes of this Part of Zambian standard ZS 688 the definitions given in Zambian standard ZS 688-1 shall apply.

4. Requirements

4.1Cable Operating Voltage

The maximum permissible operating voltage of a cable shall be 600/1 000 V or 1 900/3 300 V.

4.2 Materials and Construction

4.2.1   Conductors

Conductors shall be of plain annealed copper, or aluminium, as required, and they shall comply with the requirements of Zambian standard ZS 756-1.

4.2.2   Insulation

4.2.2.1 Material

The insulation shall be of extruded material (XLPE, HFDI or HFD2) complying with the requirements of Zambian standardZS 756-4 or ZS 756-5 (see table 12).

4.2.2.2 Thickness and insulation resistance

4.2.2.2.1The insulation resistance of the insulating material shall comply with the requirements stated in table 9, as appropriate to the type of material, cross-sectional area of the conductor and operating voltage.

4.2.2.2.2When the thickness of the insulation is determined in accordance with Zambian Standard ZS IEC 60811-1-1, the average thickness shall be at least equal to the nominal value stated in table 9, and the minimum thickness at any point may be less than the nominal value provided that the difference does not exceed 0.1 mm + 10 % of the nominal value.

4.2.2.2 Spark testing of insulation

Core insulation shall have been continuously spark tested, using the method stated in Zambian Standard ZS 764 at the appropriate spark test voltage stated in table 1, without breakdown of the dielectric.

Table 1 — SPARK TEST VOLTAGE

Cross-sectional area ofthe conductor mm2

Alternating current rms test voltage V

Above

Up to and including

600/1 000V cables

1 900/3 300 V cables

16

6 000

12 000

16

240

10 000

12 000

240

12 000

12 000

Alternatively, a dc spark test voltage 1.5 times the appropriate ac rms value may be used.

 

Core Identification

4. 2.3.1 Identification

Cores shall be identified durably and distinctly by the colouring or numbering of the insulation as follows:

   (a)   colour coding: where colour coding is used, the cores shall be insulated in the colours stated in table 2; and

   (b)   Numbering: where numbers are used, the marking shall be in a contrasting colour to that of the insulation, and the interval between any two adjacent numbers or words on the same core shall not exceed 75 mm.

Table 2 — CORE INSULATIONCOLOURCODING

Number of phase cores Colour(s) of phase cores Colour of neutral core Colour of earthing (if present)
1 Red Black Green / yellow
2 Red and yellow Black Green / yellow
3 Red, yellow and blue Black Green / yellow
4 or more Any base colour except green, with serial numbers (numerals or words) Numbered as for phase cores Green / yellow
Note: Control cables may have uniquely coloured or numbered cores or both.

4.2.3.2 Colour application

Colour shall be applied —

   (a)   throughout the thickness of the insulation; or

   (b)      in a durable manner on the entire surface of the insulation.

4. 2.3.3Earthing cores

An earthing core shall be coloured green and yellow, and the combination of the colours shall be such that one colour covers not less than 30 % and not more than 70 % of the surface of the core, and the other covers the remainder of the surface. There shall be no green and yellow coloured core in a two-core cable or in any non-earthing type cable.

NOTE:

The combination of green/yellow is reserved exclusively for the identification of the earthing core.

   4. 2.4Assembly of Cores

4. 2.4.1 General

4. 2.4.1.1The cores of a multicore cable shall be compactly laid up with an acceptable lay and in the correct sequence of their identification colours or numbers.

4. 2.4.1.2There shall be no turned cores in an assembly of shaped cores.

4. 2.4.2 Fillers

Fillers may be applied integrally with the bedding or the sheath, as applicable, and shall be used in the interstices of the cable where necessary to give the completed cable a compact circular cross-section. Filler materials shall be acceptable for the specific type of cable.

4. 2.4.3 Binder

A binder may be applied over the laid-up cores, and the material shall be acceptable for the specific type of cable.

4. 2.4.4 Concentric conductors

4. 2.4.4.1A concentric conductor shall consist of a single layer of annealed copper wires, which may be tinned, and applied helically around the laid-up cores with an acceptable lay.

4. 2.4.4.2The concentric conductor shall be separated from the laid-up cores by a separator consisting of a covering of material acceptable for the specific type of cable. The separator shall be extruded and may include a binder. It shall be possible to strip the separator from the cores without tearing the dielectric.

4. 2.4.4.3There shall be no sunken or protruding wires and the space between adjacent wires shall not exceed 4 mm. An equalising member shall be applied. The equalising member shall consist of one or more annealed copper tapes or wires applied in contact with the concentric conductors and having a suitable short lay. The nominal cross-sectional area of the equalising member shall be at least 5 % of the area of the concentric conductor to which it is applied and shall be regarded as part of the conducting area.

4. 2.4.5Cross-sectional area of concentric conductors

4. 2.4.5.1The nominal cross-sectional area of a concentric earth continuity conductor (ECC) shall conform to the appropriate value given in table 3.

4. 2.4.5.2The nominal cross-sectional area of a concentric neutral conductor shall,

   (a)   in the case of single-core cables, be at least equal to that of the phase conductor, or

   (b)   in the case of multicore cables, be in accordance with table 3.

Table 3 — SIZES OF CONCENTRICECCS AND NEUTRAL CONDUCTORS IN MULTICORECABLES

Cross-sectional area of the Phase conductor mm2

Areas of ECCs and neutral conductors mm2

Copper phase conductors

Aluminium phase conductors

ECC Copper

Neutral Copper

ECC Copper

Neutral Copper

1.5

1.0

1.5

2.5

1.5

2.5

4

2.5

4

6

4

6

10

6

10

16

10

16

6

10

25

16

16

6

10

35

16

16

6

10

50

25

25

16

16

70

35

35

25

25

95

50

50

35

35

120

70

70

35

35

150

70

70

50

50

185

95

95

70

70

240

120

120

70

70

300

150

150

95

95

400

185

185

120

120

 

Protective Coverings

4. 2.5.1 General

Non-metallic coverings shall consist of a continuous extrudate that closely fits but does not adhere to the underlying core or laid-up cores or armour. The surface of the extrudate shall have a smooth finish and its profile shall be uniform and appropriate to the type of cable.

4. 2.5.2 Lead or lead alloy sheath

4. 2.5.2.1Material: Where a metallic sheath is required it shall be of lead or of lead alloy of type E (see annex B of ZS EN 12548:1999), as required, and when it is tested in accordance with ZS 769-2 the composition shall be as given in the appropriate columns of table 4. Its malleability shall be such that, when the sheath is tested in accordance with Zambian Standard ZS 769-2 the sheath does not split or crack when the internal diameter of the expanded clause reaches 150 % of the original internal diameter.

4. 2.5.2.2Construction:

   (a)   A heat barrier shall be applied over the core assembly before the metallic sheath is applied, and shall consist of one of the following:

   (1) a layer of tape (cotton, proofed cloth, crêpe paper or compatible synthetic material) applied helically and of total thickness at least 0.3 mm; or

   (2) a bedding of extruded halogen free material of nominal thickness at least 1.0 mm.

   (b)   The metallic sheath shall be in the form of a continuous tube that is impervious to moisture, reasonably close fitting and free from defects.

Table 4 — COMPOSITION OF METALLICSHEATH

Element

Content%

Type of material

Lead alloy E*

Lead

 

Min.

Max.

Min.

Max.

Antimony

0.15

0.25

0.20

Tin

0.35

0.45

0.10

Copper

0.06

0.06

Bismuth

0.05

0.05

Tellurium

0.005

0.010

Silver

0.005

0.010

Zinc

0.002

0.002

Total other elementsb

0.01

0.01

Lead

Remainder

Remainder

99.7

4. 2.5.2.3Thickness:

When the thickness of the sheath is determined in accordance with Zambian Standard ZS IEC 60811-1-1, it shall be at least equal to the value obtained from the following formula:

t = 0.033 D + 0.7 mm (minimum 1.2 mm)

where —

tis the thickness of sheath, in millimeters; and

D   is the calculated diameter over the core or over the laid-up and filled cores, in millimeters.

NOTE Round off the calculated values of the thickness t to the nearest 0.1 mm

4. 2.5.3 Bedding of armoured cable

4. 2.5.3.1Material: Bedding shall consist of a smooth surfaced circular layer of material that complies with the requirements of ZS 756-5 (see table 12). The bedding shall not adhere to the underlying cores or binder.

4. 2.5.3.2 Thickness:

   (a)   the nominal and minimum thickness of the bedding shall be as given in table 10 or 11, as relevant; and

   (b)   when the average thickness of the bedding is determined in accordance with ZS IEC

60811-1-1, it shall be at least equal to the nominal value, and the minimum thickness at any point may be less than the nominal value, except provided that the difference shall not exceed 0.1 mm + 15 % of the nominal value.

4. 2.5.4 Armour

When so required, the cable shall be armoured, and the armouring shall comply with the following:

   (a)   Material: Armour shall consist of round wire of galvanized steel or aluminium, as required, and shall comply with ZS 756-6.

   (b)   Armouring: The nominal diameter of armour wire shall be as given in table 10 or 11, as relevant. Armour wire shall be applied with an acceptable lay, without any appreciable space between adjacent wires, and there shall be no crossed, riding or protruding wire. Joints in the wire shall be made to an acceptable standard of workmanship without sharp edges or protruding points, and multiple joints shall be acceptably staggered.

   (c)    Type of armour wire:

      (i)   For single-core cables, the armour shall be of non-magnetic wire.

      (ii)   For multicore cables the armour shall be of galvanized steel wire, except as allowed for in paragraph(d).<FC:0,112,192>

   (d)   Earth continuity conductor: When an improved conductivity in the earth continuity circuit of steel wire armoured multicore cables is required, an appropriate number of steel wires may be replaced by tinned hard-drawn copper wires of the same nominal diameter. The copper wires shall comply with the relevant requirements of ZS 756-

   1. 

The following requirements shall apply:

      (i)   The copper wires shall be of diameter equal to that of the armour, and of number as given in table 5, appropriate to the cross-sectional area of the conductor.

      (ii)   The copper wires shall be grouped together and shall not be distributed amongst the armour wires. Where eight or more armour wires are replaced by copper wires, the copper wires shall be arranged in two diametrically opposed groups to allow for a more even distribution of the clamping forces when a mechanical gland is used to terminate the cable.

Table 5 — EARTH CONTINUITYCONDUCTORIN WIRE ARMOUR

Nominal diameter of armour wire mm

Cross-sectional area of the earth conductormm2

 

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

 

0.9

2

3

4

7

10

17

26

41

57

           

1.25

2

2

3

4

5

9

14

21

30

40

57

1.6

2

2

2

2

3

6

9

13

18

25

35

49

61

76

95

2.0

             

9

12

16

23

31

39

49

61

2.5

               

8

10

15

20

25

31

39

3.15

                   

9

13

16

20

25

Material

     

Cross-sectional area of the Phase conductor

   
               

2


mm2

           

Copper

1.5

2.5

4

6

10

16

25

50

70

95

120

185

240

300

400

             

35

     

150

       

Aluminium

16

50

70

95

150

185

300

400

         

25

     

120

 

240

       
         

35

                   

4.2.5.5 Outer sheath

4. 2.5.5.1Material: The sheath shall consist of an extruded layer of material that complies with the requirements of Zambian Standard ZS 756-5 (see table 12).

4. 2.5.5.2 Thickness:

   (a)   the nominal and minimum thickness of the sheath shall be as given in table 6; and

   (b)   when the average thickness of the sheath is determined in accordance with ZS IEC

60811-1-1, it shall be at least equal to the nominal value, and the minimum thickness at any point may be less than the nominal value except that the difference shall not exceed either of the following:

      (i)   0.1 mm + 15 % of the nominal value in the case of an unarmoured cable; or

      (ii)   0.2 mm + 20 % of the nominal value in the case of an armoured cable.

Table 6 — THICKNESSOFOUTER SHEATH

Nominal diameter under sheat mm

Thickness of sheath mm

 

Armoured cable

 

With lead sheath

  Min.
Nominal

Min.

Nominal

Min.

<<

10

1.6

1.26

1.4

0.92

1.6

1.08

>10

<< 15

1.8

1.43

1.5

1.00

1.6

1.08

>15

<< 20

1.8

1.43

1.6

1.08

1.6

1.08

>20

<< 25

2.0

1.60

1.7

1.16

1.8

1.24

>25

<< 30

2.0

1.60

1.8

1.24

2.0

1.40

>30

<< 35

2.2

1.77

2.0

1.40

2.2

1.56

>35

<< 40

2.2

1.77

2.2

1.56

2.4

1.72

>40

<< 45

2.4

1.94

2.4

1.72

2.6

1.88

>45

<< 50

2.6

2.11

2.4

1.72

2.8

2.04

>50

<< 55

2.8

2.28

2.6

1.88

3.0

2.20

>55

<< 60

3.0

2.45

2.8

2.04

3.0

2.20

 

>60

3.4

2.79

3.0

2.20

3.0

2.20

 

Electrical Requirements for Finished Cables

4. 3.1 Conductor Resistance

The d.c. resistance of each conductor shall not exceed the appropriate maximum value given in ZS 756-1.

4. 3.2 Voltage Withstand

When a cable is factory tested in accordance with ZS 769-3 each core of the cable shall withstand, for 10 min without breakdown of the dielectric, a test voltage of the appropriate value given in column 3 or 4 of table 7. Alternatively, the test may be conducted for 5 min at a test voltage of the appropriate value given in column 5 or 6 of the table.

Table 7 — TEST VOLTAGES

Cables

 

Alternating current rms test voltage V

 

Rated voltage V

Type or cross-sectional area

10 minute test

5 minute test

 

Between any conductor and earth

Between conductors

Between any conductor and earth

600/ 1 000

Cables of cross sectional areanot exceeding 16 mm2

2 000

2 000

3 000

 

3 000

600 / 1 000

Cables of cross sectional area 25 mm2and above

3 000

3 000

4 500

 

4 500

1 900 / 3 300

Cables of all sizes

6 700

3 900

10 000

 

5 800

Di-Electric Resistance

When a cable is tested in accordance with Zambian Standard ZS 765, the insulation resistance of the cable shall be at least equal to the value given in the appropriate columns of table 9.

4. 4 Other Requirements for Finished Cables

4. 4.1 Reduced Flame Propagation

When a cable that is required to have reduced flame propagation properties is tested in accordance with Zambian Standard ZS 768, the height of the charred or affected portion above the bottom edge of the burner shall not exceed 2.5 m. (See also B.3 of ZS 688-1).

4. 4.2 Reduced Smoke Emission

When a cable that is required to have reduced smoke emission properties is tested in accordance with ZS IEC 61034-2, the light transmittance shall exceed the following values throughout the test:

Number of specimens of cable testedLight transmittance

4 50 %

3 60 %

2 60 %

1 70 %

4.4.3 Halogen Emission

When the cable that is tested in accordance with ZS 767, the evolution of halogen gas from the insulation, filling, bedding and sheathing obtained from the finished cable shall not lead to a pH value lower than 3.5 and conductivity higher than 100 ìs/cm

5. Inspection and methods of test

5.1   General

For convenience, the properties to be tested, the test category, the test methods and the sub-clause giving the requirements are listed in table 8:

Table 8 — LIST OF TESTS TO BE CONDUCTED

Component(s)

Test property

Test category

Test method given in

Requirement subclause

Conductor

Construction

S

ZS 756-1

4.2.1

 

Physical

     
 

properties

S

ZS 756-4 and ZS

 
     

756-5

4.2.2.1

 

Thickness

S

ZS IEC 60811-1-1

4.2.2.2

 

Spark test

R

ZS 764

4.2.2.3

 

Core identification

R,S

Visual examination

4.2.3

insulation

Assembly of cores

R

Visual examination

4.2.4

Bedding

Physical

     
 

properties

S

ZS 756-5

4.2.5.3

 

Thickness

S

ZS IEC 60811-1-1

4.2.5.3

 

Halogen gas

T

ZS 767

4.4.3

Filler and binder

Halogen gas

T

ZS 767

4.4.3

 

Composition

S

ZS 769-2

4.2.5.2

 

Belling

S

ZS 769-2

4.2.5.2

Lead sheath

Thickness

S

ZS IEC 60811-1-1

4.2.5.2 (c)

Armour

Amour

     
 

Wire diameter

S

ZS 756-6

4.2.5.4

 

Mass of Zinc

     
 

coating

S

ZS 756-6

 
 

Adhesion of Zinc

     
 

coating

S

ZS 756-6

 
 

Tensile strength

S

ZS 756-6

 
 

Elongation at break

S

ZS 756-6

 

outer Sheath

Physical

     
 

properties

S

ZS 756-2

4.2.5.5

 

Thickness

S

ZS IEC 60811-1-1

4.2.5.5

 

Halogen

T

ZS 767

4.4.3

Finished cable

Marking

R

Visual examination

ZS 688-1: 4.2.1

 

Conductor

     
 

resistance

R

ZS 756-1

4.3.1

 

Voltage withstand

R

ZS 769-3

4.3.2

 

Dielectric resistance

S

ZS 765

4.3.3

 

Fire propagation

T

ZS 768

4.4.1

 

Smoke emission

T

ZS IEC 61034-2

4.4.2

Note 1 In column 3 of this table, a code letter is given that identifies the tests as suitable for use as routine tests (R), sample tests (S) or type tests (T), but compliance with the requirements of the specification may only be fully determined from the results of tests carried out on samples of completed cable(s), using all the test methods given and a sampling procedure agreed upon. During production control, a manufacturer may use any tests considered necessary to ensure compliance with the specification but, in the case of a dispute, only the appropriate standard test methods may be used.


Note 2 In the administration of the standardisation mark scheme, the frequency of testing required and the tests to be used are the subject of a separate agreement between the Authority administering this standard and the permit holder.

5.2 Conditions of Test

5. 2.1 All tests are to be carried out at ambient temperature and pressure, unless otherwise stated in the test method.

5.2.2 Unless otherwise required in the test method, the frequency of the alternating test voltage used shall be approximately 50 Hz, and the waveform shall be substantially sinusoidal.

Table 9 — THICKNESSAND INSULATIONRESISTANCE

Cross-

XLPE and HFD1

HFD2

sectional

 

Voltage rating

       

Voltage rating

area of the

600/1000V

1 900/3300V

600/1000 V

1900/3300 V

conductor mm2

Thickness of insulation mm

Thickness of Insulation mm

Thickness of insulation mm

Insulation resistance at 23°C

Thickness of insulation mm

Insulation resistancea at 23 °C

 

Nom

Min.

Nom.

Min.

Nom

Min.

MU-km,


min.

Nom

Min.

MU-km,


Min.

1.0

0.7

0.53

0.9

0.71

15

1.5

0.7

0.53

0.9

0.71

13

2.5

0.7

0.53

1.0

0.80

12

4

0.7

0.53

1.1

0.89

11

6

0.7

0.53

1.1

0.89

9

6

0.7

0.53

1.1

0.89

9

10

0.7

0.53

2.0

1.70

1.2

0.98

8

2.2

1.88

13

16

0.7

0.53

2.0

1.70

1.2

0.98

7

2.2

1.88

11

25

0.9

0.71

2.0

1.70

1.3

1.07

6

2.2

1.88

9

35

0.9

0.71

2.0

1.70

1.3

1.07

5

2.2

1.88

8

50

1.0

0.80

2.0

1.70

1.4

1.16

5

2.2

1.88

7

70

1.1

0.89

2.0

1.70

1.4

1.16

4

2.2

1.88

6

95

1.1

0.89

2.0

1.70

1.6

1.34

4

2.2

1.88

5

120

1.2

0.98

2.0

1.70

1.6

1.34

4

2.2

1.88

4

150

1.4

1.16

2.0

1.70

1.8

1.52

4

2.2

1.88

4

185

1.6

1.34

2.0

1.70

2.0

1.70

4

2.2

1.88

4

240

1.7

1.43

2.0

1.70

2.2

1.88

4

2.2

1.88

4

280

1.8

1.52

2.0

1.70

2.3

1.97

4

2.3

1.97

4

300

1.8

1.52

2.0

1.70

2.4

2.06

4

2.4

2.06

4

380

2.0

1.70

2.0

1.70

2.5

2.15

3

2.5

2.15

3

400

2.0

1.70

2.0

1.70

2.6

2.24

3

2.6

2.24

3

480

2.2

1.88

2.2

1.88

2.7

2.33

3

2.7

2.33

3

500

2.2

1.88

2.2

1.88

2.8

2.42

3

2.8

2.42

3

600

2.4

2.06

2.4

2.06

2.8

2.42

3

2.8

2.42

3

630

2.4

2.06

2.4

2.06

2.8

2.42

3

2.8

2.42

3

740

2.5

2.15

2.5

2.15

2.8

2.42

3

2.8

2.42

3

800

2.6

2.24

2.6

2.24

2.8

2.42

3

2.8

2.42

3

960

2.7

2.33

2.7

2.33

2.9

2.51

3

2.9

2.51

3

1000

2.8

2.42

2.8

2.42

3.0

2.60

3

3.0

2.60

3

1200

2.9

2.51

2.9

2.51

3.2

2.78

3

3.2

2.78

3

Table 10 — BEDDING AND WIRE ARMOUR OF CABLES WITHOUTLEAD SHEATH

Nominal diameter over core or laid up cores mm

Thickness ofextruded bedding mm

Nominal adiameter of armour wire


mm

Nominal

Min.

<< 10

0.8

0.58

0.9b

>10 << 15

0.8

0.58

0.9b

>15 << 20

1.2

0.92

1.60c

>20 << 25

1.2

0.92

1.60

>25 << 35

1.4

1.09

2.0

>35 << 55

1.6

1.26

2.5

>45 << 60

1.6

1.26

2.5

>60

1.6

1.26

3.15

Table 11 – BEDDING AND WIRE ARMOUR OF CABLES WITH LEAD SHEATH

Nominal diameter over core or laid up cores mm

Thickness of extruded bedding mm

Nominal adiameter of armour wire


mm

Nominal

Min.

<< 10

0.8

0.58

0.9b

>10 << 15

0.8

0.58

0.9b

>15 << 20

1.2

0.92

1.60c

>20 << 25

1.2

0.92

1.60

>25 << 35

1.4

1.09

2.0

>35 << 55

1.6

1.26

2.5

>45 << 60

1.6

1.26

2.5

>60

1.6

1.26

3.15

Table 12 — PERMISSIBLE MATERIALS

[See ZS 756-4 and ZS 756-5]

Insulation

Bedding

Sheath

Max conductor operating temperature

XLPE

HFB1

HFS1 / HFS2

90ºC

HFD1

HFB1

HFS1 / HFS2

90ºC

HFD2

HFB / HFB1

HFS1 / HFS2

70ºC

 

SECOND SCHEDULE

[Paragraph 3]

1.

ZS 688 Part 1

General Cables

2.

ZS 688 Part 2

Wiring Cables

3.

ZS 688 Part 3

PVC Distribution Cables

4.

ZS 688 Part 4

XLPE DistributionCables

5.

ZS 688 Part 5

Halogen-free Distribution Cables

 

STANDARDS (COMPULSORY STANDARDS) (DECLARATION) ORDER, 2017

[Section 7]

Arrangement of Paragraphs

   Paragraph

   1. Title

   2. Declaration of compulsory standards

   3. Application of standards

      FIRST SCHEDULE

      SECOND SCHEDULE

SI 68 of 2017.

 

1. Title

This Order may be cited as the Standards (Compulsory Standards) (Declaration) Order, 2017.

 

2. Declaration of compulsory standards

The Standards set out in the First Schedule are declared as compulsory standards.

 

3. Application of standards

The Standards set out in the First Schedule apply to the commodities listed in the Second Schedule.

 

FIRST SCHEDULE

[Paragraph 3]

ZAMBIAN STANDARD ZS 063

PETROLEUM JELLY - SPECIFICATION

1.   SCOPE

   This Zambian Standard specifies requirements and methods of sampling and testing for snow-white, white and yellow petroleum jellies for the cosmetic industry.

2.   TERMINOLOGY

   For the purpose of this Standard, the following definitions apply—

   "snow-white petroleum jelly" means a completely decolourised petroleum jelly;

   "white petroleum jelly" means a partially decolourised jelly; and

   "yellow petroleum jelly" means a purified, semi-solid mixture of hydrocarbons obtained from petroleum.

3.   REQUIREMENTS

   3.1. Appearance

      Petroleum jelly shall be an unctuous mass transparent in thin layers and possessing a slight fluorescence only, even after being melted.

   3.2. Taste

      Petroleum jelly shall be tasteless.

   3.3. Odour

      Petroleum jelly shall be odourless at room temperature and there shall be no objectionable odour when it is heated in boiling water for 30 minutes.

   3.4. Solubility

      Petroleum jelly shall be insoluble in water and in ethyl alcohol (90 per cent), but shall be soluble in petroleum ether and in chloroform.

   3.5. Added colouring matter

      When 5g of yellow or white petroleum jelly is boiled with 10ml of alcohol (90 per cent), the alcohol shall not be coloured.

   3.6. Requirements

      Petroleum jelly covered by this specification shall comply with the requirements given in Table 1 for colour and Table 2 for other requirements.

TABLE 1—COLOUR REQUIREMENTS FOR PETROLEUM JELLY

Type

Lovibond Colour Composition

National Petroleum Association Colour Number

2-in cell

½ -in cell

Snow-white

Not darker than 2 yellow

 

White

Not darker than 35 yellow 2 red

Not darker than 35 yellow 4 red

1½ max

Yellow

   

1.   PACKAGING AND LABELLING

   1.1. Packaging

      (a)   Petroleum jelly shall be packed in clean, dry containers of adequate strength and closure to prevent damage, breakage or contamination during transportation and to allow for re-closing.

      (b)   The container shall be filled to not more than one per cent above the declared net mass of the contents.

   1.2. Labelling

      The following information shall appear clearly on each container of petroleum jelly or on a label fixed to the container—

      (i)   the name "Petroleum jelly";

      (ii)   the grade "cosmetic";

      (iii)   the colour;

      (iv)   the manufacturer’s name and registered trade mark brand; and

      (v)   the net mass of the contents.

TABLE 2—REQUIREMENTS FOR PETROLEUM JELLY

Sl. No.

Property

Requirement

Method of test (Ref. ZS 143)

1.

Kinematic viscosity at 93°C, cst<BC:0,0,0,DC>1

7.4 to 17.02

2

2.

Melting point, °C

38 to 56

3

3.

Specific gravity at 60°C

0.815 to 0.880

4

4.

Saponifiable matter

Nil

5

5.

Sulphated ash, per cent by mass, max

0.10

6

6.

Free acids and alkalis

To pass the test

7

7.

Organic acids

To Pass the test

8

8.

Sulphur and sulphides

To pass the test

9

9.

Arsenic (as As<BC:0,0,0,DC>2O<BC:0,0,0,DC>3) parts per million, max

2

10

10.

Absorbance, max at wavelength—

 

13

280-289nm

0.25

290-299nm

0.20

300-359nm

0.14

360-400nm

0.04

11.

Heavy metals (as Pb), parts per million, max

20

11

12.

Iodine value (Wigs), max

1.5

12

 

Melt the material completely and examine visually in sunlight. There shall be no fluorescence

 

100 to 275, as agreed between the purchaser and the supplier

13.

FluorescenceDone only when demanded.*

   

14.

Consistence

   

1.   SAMPLING AND COMPLIANCE WITH THE SPECIFICATION

   1.1. Sampling

      Sampling of the product shall be carried out in accordance with Annex A.

   1.2. Number of tests

      Tests for all the requirements given in clause 3 shall be conducted on the composite sample.

   1.3. Criteria for conformity

      A lot shall be declared as conforming to this specification if the composite sample satisfies all the requirements (see clause 3).

 

ANNEX A
SAMPLING PROCEDURE

A. 1. General Requirements

   A.1.1. In drawing, preparing, storing and handling test samples the following precautions and directions shall be observed.

   A.1.2. Samples shall not be taken in an exposed place.

   A.1.3. The sampling instrument shall be clean and dry.

   A.1.4. Precaution shall be taken to protect the samples, the material being sampled, the sampling instrument and the containers for samples from contamination.

   A.1.5. To draw a representative sample, the contents of each container selected for sampling shall be mixed as thoroughly as possible by suitable means.

   A.1.6. The sample containers shall be of a size that they are almost completely filled by the sample.

   A.1.7. Each sample container shall be sealed air-tight with a suitable stopper after filling, and marked with full details of sampling, the date of sampling and the year of manufacture of the material.

A. 2. Scale of Sampling

A.2.1.    Lot

All the cartons in a single consignment of the material drawn from a single batch of manufacture shall constitute a lot. If a consignment is declared to consist of different batches of manufacture, the batches shall be marked separately and the groups of cartons in each batch shall constitute separate lots.

Samples shall be tested from each lot for ascertaining conformity of the material to the requirements of the specification.

A.2.2.    The number of cartons (n) to be chosen from the lot shall depend on the size of the lot (N) and shall be in accordance with column 1 and 2 of Table A. 1.

   A.2.3. The cartons and containers to be selected for sampling shall be chosen at random from the lot and for this purpose random number tables shall be used. In case the tables are not available, the following procedure shall be adopted—

Starting from any container, count them as 1, 2, 3 etc. up to r and so on, in a systematic manner, where r is the integral part of N/n. Every rth container thus counted shall be withdrawn from the lot.

TABLE A. 1—SCALE OF SAMPLING

1

2

3

Lot Size

Number of Cartons to be Selected

Percentage of Containers to be Selected from Each Carton

N

N

 

3 to 50

3

10

51 to 200

4

10

201 to 400

5

10

401 to 650

6

10

651 to 1000

7

10

A. 3. Test Samples and Reference Sample

A.3.1. Preparation of Test Samples

Draw with an appropriate sampling instrument, the material from different parts of each carton selected (See Table A. 1.). The total quantity of the material drawn from each carton shall be sufficient to conduct the test for all the characteristics given under 3 and shall not be less than 200g.

Thoroughly mix all portions of the material drawn from the same carton. Out of these portions, equal quantity shall be taken from each of the selected cartons and shall be well mixed together so as to form a composite sample weighing at least 0.5 kg. This composite sample shall be divided into three equal parts, one for the purchaser, and another for the supplier and the third for reference.

A.3.2. Reference Sample

The reference sample shall consist of the composite sample marked for this purpose and shall bear the seals of the purchaser and the supplier. It shall be kept at a place agreed to between the purchaser and the supplier and shall be used in case of dispute between the two.

Zambian Standard ZS 065

PURE GLYCERINE - SPECIFICATION

1. SCOPE

   This Zambian Standard specifies the requirements for pure glycerine.

2.    REQUIREMENTS

   2.1. General

      Pure glycerine covered by this specification shall, in addition to requirements given in sub-clauses 2.2. to 2.6., comply with the requirements given in Table 1, when tested in accordance with the corresponding methods referred to in column 4 of Table 1.

   2.2. Description

      Zambian Standard pure glycerine shall be a clear odourless viscous liquid consisting essentially of glycerol.

   2.3. Appearance

      The material shall be free from visible foreign matter.

   2.4. Odour

      The material shall be free from odour when tested by the method described in ZS 144: Part 13.

   2.5. Taste

      The material shall taste sweet followed by a sensation of warmth.

TABLE 1—REQUIREMENTS FOR PURE GLYCERINE

SI. No.

Property

Requirements

Methods of Test (Ref. to ZS 144 part)

1.

Alkalinity or acidity, maximum miliequivalent per 100g

0.064

4

2.

Arsenic contents, as As mg/kg, maximum

2.0

6

3.

Chloride limit

No turbidity

7

4.

Glycerol content per cent by mass, minimum

99.0

3

5.

Lead content as Pb, mg/kg, maximum

1.0

10

6.

Total heavy metals content, as Pb, mg/kg, maximum

5.0

9

7.

Organic chloride limit

Turbidity produced shall not be greater than that produced by the control

8

8.

Relative density (20°C/20°C), range

1.258 - 1.263

14

9.

Saponification equivalent, maximum miliequivalent per 100g

0.64

12

10.

Sugars

Nil

15

11.

Sulphated ash, per cent by mass, maximum

0.010

5

12.

Test for reducing substances

The colour produced shall not be darker than that produced by the standard dextrose solution

11

3.   SAMPLING AND SAMPLE SIZES

   3.1. General

      Sampling and sample's sizes shall be as given in ZS 144: Parts 1 and 2.

   3.2. Reference sample

      The reference sample shall consist of the composite sample marked for this purpose and shall bear the seals of the purchaser and the supplier. It shall be kept at a place agreed to between the purchaser and the supplier and be used in case of a dispute between the two.

4.   TESTS AND CRITERIA FOR CONFORMITY

   4.1. Tests

      Tests for all the requirements given in clause 2 shall be conducted on the composite sample.

   4.2. Criteria for conformity

      A lot shall be declared as conforming to this specification if the composite sample satisfies all the requirements in clause 2.

5.   PACKAGING

   The product shall be packaged in suitable containers that will prevent contamination of the product.

6.   LABELLING

   The label on the container shall bear the following information—

   (i)   the name of the product, that is, "Pure Glycerine";

   (ii)   the name and address of the manufacturer;

   (iii)   the brand name if any;

   (iv)   the lot or batch number; and

   (v)   the net volume.

Zambian Standard ZS 190

DRINKING WATER - SPECIFICATION

1.   SCOPE

   This Zambian Standard prescribes requirements for potable drinking water suitable for human consumption.

2.   DEFINITIONS

   For the purpose of this Zambian Standard, the definitions given in ZS 191 shall apply.

3.   NON-INJURIOUS CONSTITUENTS OF DRINKING WATER

   3.1. General

      Parameters that do not pose a risk to human health are addressed under clause 4.

   3.2. Requirements

      (a)   General physical and chemical characteristics

         Drinking water shall comply with the general physical and chemical requirements as given in Table 1.

TABLE 1—GENERAL PHYSICAL CHARACTERISTICS OF DRINKING WATER

Parameters

Requirement

Method of test

Odour

Unobjectionable to most consumers

ZS 312 Part 1

Colour (True colour units or TCU)

15 (max)

ZS ISO 7887

Taste

Unobjectionable to most consumers

ZS ASTM 2106B

Ph

6.5 - 8.0

ZS ISO 10523

Hardness (total) as calcium carbonate CaCO<BC:0,0,0,DC>3 (mg/litre)

500 (max)

ZS ASTM D1126

Dissolved solids (total) mg/l

1,000 (max)

ZS 312 Part 19

Turbidity (NTU)

5 (max)

ZS ISO 7027

Conductivity (µs/cm)

1,500 (max)

ZS ISO 7888

   (a)   Non-toxic chemical substances

      Drinking water shall comply with the following specifications for non-toxic chemical substances as given in Table 2.

TABLE 2—NON-TOXIC CHEMICAL SUBSTANCES IN DRINKING WATER

Substance

Requirements (mg/litre)

Method of test

Calcium (Ca)

200 max

ZS ISO 6058

Chloride (Cl)

250 (max)

ZS ISO 9297

Chlorine residue

0.2 - 0.5

ZS ISO 7393 Part 1

Copper (Cu)

1.0 (max)

ZS ISO 8288

Iron (Fe)

0.3 (max)

ZS ISO 11885

Magnesium (Mg)

150 (max)

ZS ISO 7980

Sulphate (SO<BC:0,0,0,DC>24)

400 (max)

ZS ISO 312 Part 3

Zinc (Zn)

3 (max)

ZS ISO 8288

Phenolic compounds (as phenol)

0.002 (max)

ZS ISO 6439

Detergents (alkyl benzene sulphate)

1.0 (max)

ZS ISO 312 Part 20

Sodium

200 (max)

ZS ISO 9964 Part 1

   (c)   Total residual chlorine

      (i)   The total residual chlorine in treated drinking water shall be sufficient for complete elimination of all micro-organisms. Drinking water shall have residual chlorine concentration as outlined in Table 2 on receipt by the consumer.

      (ii)   The amount of chlorine residue shall be increased during epidemic cases or special cases according to instructions from the Ministry responsible for health.

Note:      In cases of water treatment with ozone, saturated iodine solution, ultraviolet rays or by any other treatment other than chlorine, the treatment shall be sufficient to eliminate all the micro-organisms. Treated water shall comply with the microbiological requirements in Table 5.

4.   INJURIOUS CONSTITUENTS OF DRINKING WATER

   1.1. General

      Parameters that pose a risk to human health are addressed under clause 5.

   1.2. Requirements

      (a)   Specific toxic chemical substances

         Drinking water shall comply with the specifications for toxic chemicals as given in Table 3.

TABLE 3—TOXIC CHEMICAL SUBSTANCES IN DRINKING WATER

<PS:"QT-I Table">Substance <PS:"QT-I Table">Maximum permissible limit (mg/litre) <PS:"QT-I Table">Method of test

Aluminium (Al)

0.2

ZS ISO 10566

Arsenic (As)

0.01

ZS ISO 11969

Cadmium

0.003

ZS ISO 5961

Barium

0.7

ZS ISO 11885

Chromium (Cr)

0.05

ZS ISO 9174

Cobalt (Co)/litre

0.5

ZS ISO 8288

Cyanide (CN)

0.01

ZS ISO 6703-1

Flouride (F)

1.5

ZS ISO 10359 Part 1

Lead (Pb)

0.01

ZS ISO 8288

Mercury (Hg)

0.001

ZS ISO 5666

Manganese (Mn)

0.1

ZS ISO 6333

Nitrates (NO<BC:0,0,0,DC>3 N)

10

ZS ISO 7890 Part 3

Nitrate (NO<BC:0,0,0,DC>2 N)

1.0

ZS ISO 312: Part 13

Selenium (Se)

0.01

ZS ISO 9965

Silver (Ag)

0.05

ZS ISO 11885

   (b)   Pesticides

The maximum permissible limits of pesticides if present in drinking water shall be as outlined in Table 4.

TABLE 4—PESTICIDE LIMITS IN DRINKING WATER

Pesticide

Maximum permissible limit (µg/litre)

Method of test

Aldrin/dieldrin

0.01

ZS 312: Part 15

Chlordane

0.3

2,4-D

30

DDT

1.0

Endonsulfan

2

Endrin

0.2

Heptachlor and heptachlor epoxide

0.1

Hexachlorobenzene

0.01

Lindane (Gamma BHC)

3.0

Methoxychlor

30

Toxaphene

5

Note: Corresponding chemical names of the pesticides in Table 4 are given in Annex A.

   (c)   Trihalomethanes

      The concentration of trihalomethanes (chloroform, bromodichloromethane, dibromochloromethane and tribomomethane) shall not exceed 30 µg/litre when tested in accordance with ZS 312: Part 18.

   (d)   Chemical substances which indicate pollution

      Considerable variations in the amount of the following chemical substances in drinking water from the prevailing quantities in the water source area shall indicate presence of pollution—

      (i)   organic matter;

      (ii)   albuminoid nitrogen;

      (iii)   nitrates;

      (iv)   hydrogen sulphide;

      (v)   dissolved oxygen;

      (vi)   free carbondioxide;

      (vii)   phosphate;

      (viii)   ammonia; and

      (ix)   nitrite.

   (e)   Microbiological requirements

      Coliforms in piped supply and un-piped supplies of drinking water shall not exceed the limits given in Table 5.

TABLE 5—MICROBIOLOGICAL REQUIREMENTS OF PIPED AND UN-PIPED DRINKING WATER

Type of Drinking Water

Maximum Permissible Limit in 100 ml

Remark

Faecal Coliforms

Coliform Organisms

1. Piped Water Supplies

Treated water entering the distribution system

0

0

In any one sample

Untreated water entering the distribution system

0

3

In any one sample

0

0

In any two consecutive samples

0

0

 

0

20

0 in 95 per cent of yearly samples

0

20

In an occasional sample but not in consecutive samples

Water in the distribution system

0

10

In any two consecutive samples

0

20

In an occasional sample but not in consecutive samples

2. Un-Piped Water Supplies

 

0

20

In any two consecutive samples

0

50

In an occasional sample but not in consecutive samples

Emergency supplies of water

0

0

 

   (f)   Biological characteristics

      Drinking water shall be completely free from insects and their ova or cyst, their vesicles or parts, and free from amoeba, algae, mould and parasites.

   (g)   Radioactive requirements

      The levels of radioactive constituents of drinking water shall not be more than the limits given in Table 6.

TABLE 6—RADIOACTIVE REQUIREMENTS FOR DRINKING WATER

Substance

Maximum permissible limit (Bq/litre)

Method of test

Gross alpha activity

0.1

ZS ISO 9696

Gross beta activity

1

ZS ISO 9697

5.   SAMPLING

   Representative samples shall be drawn according to sampling schemes designed in accordance with ZS 276.

6.   TESTING AND CONFORMITY TO THE STANDARD

   The drinking water shall conform to this standard if it meets all the requirements prescribed in this standard.

Zambian Standard ZS 233

CRUDE EDIBLE VEGETABLE OILS - SPECIFICATION

1.   SCOPE

   This Zambian Standard specifies the requirements for crude edible vegetable oils obtained from groundnuts (Arachia, hypogen), cotton seeds (Gossypium, spp.), sunflower seeds (Helianthus, annuus), soya beans (Glycine max), olives and palms (Elaeis guineensis).

2.   NORMATIVE REFERENCES

   (a)   ZS 002: Methods of sampling fats and fatty oils.

   (b)   ZS 226: Methods of test for oils and fats.

      Part 1: Physical tests

      Part 2: Chemical tests

3.   DEFINITIONS

   In this standard, the definitions given in clause 2 of ZS 226: Part 2 and the following shall apply—

   "crude edible vegetable oil" means the oil obtained by the process of expression or solvent extraction from vegetable sources without further processing;

   "virgin oil" means the product that has been subjected to mechanical procedures such as expelling or pressing and application of heat without altering the nature of the oil; and

   "cold pressed oil" means the product that has been subjected to mechanical procedures such as expelling or pressing and without the application of heat, without altering the nature of the oil.

   Note: Purification may be done by washing with water, settling, filtering and centrifuging only.

4.   QUALITY REQUIREMENTS

   4.1. Description

   (a)   Crude groundnut oil: golden yellow oil obtained from well-selected groundnut kernels free from fungal infection, which may deposit a small quantity of steariness after standing at a low temperature. It has a pleasant nutty taste and odour.

   (b)   Crude soya bean oil: medium to dark yellow brown liquid oil, which on standing, deposits an appreciable quantity of steariness. It has a slight characteristic odour.

   (c)   Crude sunflower oil: pale yellow oil, which may deposit small quantities of steariness. It has a slight characteristic odour.

   (d)   Crude cottonseed oil: medium to dark yellow brown oil, which on standing deposits an appreciable quantity of stearine. It has a slight characteristic odour.

   (e)   Crude or virgin olive oil: clear, yellow or green oil, with specific odour and taste, free from odour or taste indicating alteration or pollution.

   4.2. Physical requirements

      When tested in accordance with ZS 226: Part 1, the physical requirements of crude edible vegetable oils shall conform to those specified in Table 1.

TABLE 1—PHYSICAL REQUIREMENTS FOR CRUDE EDIBLE VEGETABLE OILS

Characteristic

Requirements

 

Groundnut

Cottonseed

Sunflower

Soya beans

Palm

Virgin/Cold pressed

Specific gravity (20°C/20°C)

0.912-0.920

0.918-0.926

0.918- 0.923

0.919-0.921

0.891- 0.899

0.910

Refractive index (D<BC:0,0,0,DC>Na at 40°C)

1.4568- 1.4608

1.4650- 1.4660

1.4536- 1.4641

1.4650- 1.4710

1.454- 1.456

1.4677- 1.4707

Colour in 5.25"
Lovibond cell:


Red (max)
Yellow (max)

2

12

2

12

25

25

30

25

Moisture and volatile matter, at 105°C, % max

1

1

1

1

1

0.2

Titre, °C

27-32

30-37

16-20

20-21

19-23.5

             

   4.3. Chemical requirements

      When tested in accordance with ZS 226: Part 2, the chemical requirements of crude edible vegetable oils shall conform to those specified in Table 2.

TABLE 2—CHEMICAL REQUIREMENTS FOR CRUDE EDIBLE VEGETABLE OILS

Characteristic

Requirements

 

Groundnut

Cottonseed

Sunflower

Soya beans

Palm

Virgin/Cold pressed

Saponification value, mg KOH/g

187-196

190-195

190-195

189-198

190-209

184-196

Unsaponifiable matter, % max.

10

15

15

10

12

15

Peroxide value, mEq/Kg, max.

10

10

10

10

10

15

Free fatty acids, % max.

3

3

3

2

3

3

Iodine value (Wijs)

86-107

124-139

124-139

100-123

50-55

75-94

5.   PACKAGING, STORAGE AND TRANSPORTATION

   Crude oil shall be packed in clean food grade drums or tankers.

6.   USE

   Crude oil shall be used as a raw material in the manufacture of edible fats, oils and shortenings.

7.   SAMPLING

   Representative samples of the material shall be drawn as described in ZS 002.

8.   TESTING

   Tests shall be carried out as prescribed in ZS 226: Parts 1 and 2.

9.   COMPLIANCE WITH THE STANDARD

   The lot shall be considered to conform to the requirements of this standard, if the test samples satisfy the requirements.

Zambian Standard ZS 327

BLENDED (PHYSICAL MIXTURE) FERTILISERS - SPECIFICATION

1.   SCOPE

   This Zambian Standard specifies the requirements for blended fertilisers (or physical mixtures of fertilisers) intended for use as fertilisers.

2.   NORMATIVE REFERENCES

   2.1. The following standards are referred to in this standard—

   (a)   ZS 324: Part 2 - Determination of total phosphorous - Quinolinium Phosphomolybdate method;

   (b)   ZS 324: Part 3 - Determination of total nitrogen - Kjedahl method;

   (c)   ZS 324: Part 12 - Extraction of water soluble phosphates;

   (d)   ZS 324: Part 13 - Determination of total nitrogen - Titrimetric method;

   (e)   ZS 324: Part 17 - Determination of water soluble potassium content;

   (f)   ZS 325 - Fertilisers and soil conditioners - Vocabulary;

   (g)   ZS 605, ZS 606, ZS 607, ZS 608, ZS 609, ZS 610, ZS 612, ZS 613, ZS 614, ZS 615 (Straight fertilisers); and

   (h)   ZS 431: 2004 - Compound fertilisers - Specification.

   2.2. All standards are subject to revision and since any reference to a standard is considered to be a reference to the latest edition of that standard, parties to agreements based on this standard are encouraged to ensure the use of the most recent editions of the standards indicated above.

3.   DEFINITIONS

   In this standard, the definitions given in ZS 325 and the following shall apply—

   "blended fertiliser" means a product obtained by physical mixing of different fertiliser ingredients or stock materials and containing more than one of the major plant nutrients, namely, nitrogen, phosphorous and potassium and/or are simple mixtures of more than one fertiliser in which chemical interaction does not take place and they may be mixed in different proportions;

   "compatibility" means a non-chemical reaction of two or more fertiliser ingredients (materials) when mixed;

   "crop" means a plant for which a particular blended fertiliser shall be used to provide nutrients in a field for a particular crop season;

   "filler" means a substance added to fertiliser materials to provide bulk, prevent caking, or serve some purpose except providing essential plant nutrients;

   "ingredients (source)" means materials, usually straight fertilisers, used as sources of particular nutrients in a blended fertiliser (See Annex A);

   "segregation" means a non-uniformity of composition throughout a blended fertiliser lot; and

   "soil testing" means a process of taking a representative sample from a field and testing it for available nutrients and other properties, for example, pH.

4.   REQUIREMENTS

   4.1. General

   (a)   Blended fertilisers shall be in the form of powder, crystals or granules and shall be non-caking, free flowing and free from visible impurities.

   (b)   The blended fertiliser shall be properly mixed so that the ingredients are uniformly distributed and there is no segregation of the ingredients.

   (c)   There shall be very negligible dust or fine particles settling at the bottom of the blended fertiliser (bags or bulk).

   4.2. Particle size

   (a)   The size range as well as the particle size distribution of the different ingredients of the blended fertilisers shall be compatible.

   (b)   The particle size (sieve analysis) of blended fertilisers shall be such that a minimum of 90% shall pass through 1.5 mm - 5.0 mm sieve and retained on 1.00 mm sieve for standard products.

   4.3. Chemical requirements

   (a)   General

      Blended fertilisers shall be essentially a mixture of chemically compatible (See Annex B) and physically homogenous constituents.

   (b)   Nutrient composition

      (i)   If a particular blended fertiliser has the same specification as any of the compound fertilisers in ZS 431 (Compound Fertilisers - Specification), it shall be required to meet the analysis of that particular compound fertiliser. Other blended fertilisers not contained in ZS 431 shall conform to the labelled nutrient composition upon laboratory testing.

      (ii)   Every ingredient (source) of the declared nutrients in the blended fertilisers shall be readily available to the particular crop for the particular crop season and not just past the period when the crop needs the nutrients. This may require that both the farmer and the supplier are aware of the soil characteristics through soil testing (any other factor in the soil or weather conditions which may affect the fertiliser performance) for which the particular blended fertiliser is being mixed so that good results are realised. This also means that the crop shall not show adverse deficiency of any nutrient of an efficiently and effectively applied blended fertiliser.

      (iii)   Elemental nutrient sources or ingredients if used shall also be readily available to the crop as stated in (ii). Non-soluble elemental sources shall not be used in blended fertilisers.

      (iv)   If a micronutrient source in powder form is added as a coat on to the surface of the blend granules or crystals, an effective binder or coating agent (to enhance adherence) shall be used so that there is no segregation of the micronutrient onto the bottom of the blended fertiliser.

         Note: Only micronutrient sources shall be in powder (fine) form.

      (v)   The filler used in the blended fertiliser shall by no means substitute any of the declared nutrients.

      (vi)   The composition nutrients of blended fertiliser shall be declared in terms of total nitrogen, total phosphorous or water-soluble phosphorous and water-soluble potassium in accordance with ZS 324: Parts 3 or 13, ZS 324: Parts 2 or 12 and ZS 324: Part 17 respectively. The permissible limit of variation for these nutrients shall be as follows—

         The actual percentage nutrient content of each declared nutrient shall be within ± 2% of the fertiliser when determined in accordance with the declared content; and

         The sum of actual percentage nutrient content of all declared nutrients shall be within ± 2.5% unit of the sum of the declared contents.

5.   SAMPLING

   Sampling shall be carried out in accordance with ZS 356: Part 1.

6.   PACKAGING

   6.1. Individual container

   (a)   Blended fertilisers shall be packaged in suitable, clean, sound and moisture proof containers or packages.

   (b)   Suitable packaging materials include polypropylene, and high density polyethylene bags with an inner loose tubular liner polyethylene film.

   6.2. Bulk container

      The fertiliser may also be supplied in bulk. Where it is supplied in bulk, the bulk container shall be sound, clean, dry and capable of protecting the product from adventitious contamination and moisture absorption.

7.   LABELLING AND MARKING

   7.1. Individual container

   (a)   Each container of blended fertilisers shall be labelled indelibly with the following particulars—

      (i)   name of the fertiliser;

      (ii)   the word "BLENDED", conveniently in brackets;

      (iii)   the nominal percentage composition of the mixture as N: P<BC:0,0,0,DC>2O<BC:0,0,0,DC>5: K<BC:0,0,0,DC>2O and trace elements in elemental form;

      (iv)   the values of P (as P<BC:0,0,0,DC>2O<BC:0,0,0,DC>5);

      (v)   traceability notation;

      (vi)   name and address of the manufacturer or supplier; and

      (vii)   any other marking requirements laid down by the purchaser.

   (b)   Each container should carry relevant safety and environmental effect markings.

   7.2. Bulk container

      Where the fertiliser is supplied in bulk, the labelling information shall accompany the delivery note.

8.   TEST REPORT

   8.1. The test report for the particular batch or lot of the blended fertiliser shall declare the source or ingredients and the proportions in which they were mixed for the particular nutrient composition stated.

   8.2. If a binder or coating agent is used for the adherence of the micronutrients onto the fertiliser granules or crystals, it shall also be declared (name and quantity) in the test report.

   8.3. Any filler and its proportion, used in the blended fertiliser, shall be declared in the test report.

9.   COMPLIANCE WITH THE STANDARD

   A lot of a blended fertiliser shall be considered to comply with this standard if on inspection and testing, the provisions of clauses 4,6,7 and 8 are satisfied.

ANNEX A

(Informative)

FERTILISER MATERIALS AND THEIR ANALYSIS COMMONLY USED IN BLENDED FERTILISER FORMULAE ANALYSIS (%)

Material

N

P<BC:0,0,0,DC>2O<BC:0,0,0,DC>5

K<BC:0,0,0,DC>2O

S

Diammonium phosphate

18

46

0

0

Monoammonium phosphate

11

52

0

0

Ammonium sulphate

21

0

0

24

Ammonium nitrate

34

0

0

0

Urea

46

0

0

0

Triple superphosphate

0

45

0

0

Muriate of potash

0

0

60

0

Sulphate of potashfiller

0

0

48

18

Filler

 

(not specified)

   

Note: Fertiliser materials (straight fertilisers) used in blended fertilisers, as sources of specific nutrients are not limited to the ones mentioned here. For more details, reference can be made to ZS 431 and straight fertiliser standards ZS 605, ZS 606, ZS 607, ZS 608, ZS 609, ZS 610, ZS 612, ZS 613, ZS 614 and ZS 615.

ANNEX B

(Informative)

CHEMICAL COMPATIBILITY OF BLENDED MATERIALS

Zambian Standard ZS 357

PRESSED STEEL DOOR FRAMES - SPECIFICATION

1.   SCOPE

   This specification sets out the sizes, fittings and finish for pressed steel door frames.

2.   MATERIAL

   Pressed steel door frames shall be manufactured from good commercial quality mild steel of not less than 18 BG<BC:0,0,0,DC>+ (1.2 mm).

Note: +BG - Birmingham gauge

3.   SIZES

   The door frames shall be suitable for doors 45 mm nominal thickness and the door frames shall conform to the following door dimensions in Figures 1 to 3 and Table 1—

TABLE 1—MODULAR AND OVERALL WIDTHS FOR DOOR FRAMES

Door width

Single door size

Double door size

 

625

725

825

1125

1425

Overall

695

795

895

1195

1495

Modular

700

800

900

1200

1500

Note:

   1. All dimensions are in "mm".

   The sizes include those for cupboard frames

4.   PROFILES

   4.1. Double rebated frames

      Steel door frames shall normally be double rebated and made in accordance with one of the three profiles 1 M, 1½ M or 2 M as shown in Figure 4.

 

      1. Single door frames

 

      2. Double door frames

Note:

   1. Module and overall widths (See Table 1).

   2. All cupboard frames are for a 1 M wall and it is therefore not necessary to specify wall thickness when ordering.

   3. Modular height: 2600 mm

      Overall height: 2595 mm

Figure 1 - Single doorframes

 

   1. Plain door frames

 

   2. Door frames with fanlights beaded for fixed glazing (22F type)

 

   3. Door frames with fanlights beaded for timber sashes (24F type)

Note:

See Figure 1 for modular and overall heights

Figure 2 - Double door frames

 

   1. Plain door frames

 

Modular height: 2200 mm
Overall height: 2195 mm

   2. Door frames with fanlights beaded for fixed glazing (22F type)

 

Modular height: 2400 mm
Overall height: 2395 mm

   3. Door frames with fanlights hinged for timber sashes (24F type)

Figure 3-Cupboard frames

 

½ M Profile double rebate 1½ M Profile single rebate

 
 

½M Profile double rebate 1 ½ Profile single rebate

 
 

2 M Profile double rebate 2 M Profile single rebate.

Note:

Dimensions A: 12 mm, B: 48 mm, C: 32 mm, D: 12 mm

Figure 4 - Frame profiles

Each of the three profiles shall be supplied to suit doors of either hand. The profile sizes shall be as given in Table 2.

TABLE 2—DIMENSIONS FOR PROFILE SIZES

Profile

Overall size

Thickness of wall
(to be plastered both sides)

1 M

<PS:"QT9PointHeading">150 <PS:"QT9PointHeading">100

1½ M

<PS:"QT9PointHeading">200 <PS:"QT9PointHeading">150

2 M

<PS:"QT9PointHeading">250 <PS:"QT9PointHeading">200

All dimensions in millimetres.

   4.2. Single rebated frames

      Single rebated door frames and other profile sizes shall be matters for agreement between manufacturer and purchaser.

<PS:"QT-I Table">5.   CONSTRUCTION

   5.1. A door frame shall consist of a hinge jamb, lock jamb and head, the whole of which shall be welded together.

   5.2. Two base ties shall be applied to the frame.

   5.3. The corners shall be adequately reinforced with mild steel of thickness not less than 14 BG
(2 mm), 76 mm, from the corner in either directions.

Note:

   (a)   The corner plate shall be optional when corners are joined by continuous welding.

   (b)   The welded frames shall be square and without twist. All welds on surfaces which will remain exposed after building-in shall be cleaned off flush.

6.   BASE TIES

   3.1. Base ties shall be of mild steel of a thickness not less than 18 BG (1.2 mm) and shall have an L-shaped section with a girth of not less than 25 mm.

   3.2. The base ties shall be positioned to allow for a 25 mm floor screed and finish as shown in Figures 5 and 6.

7.   FITTINGS

   Each door frame shall be provided with the following fittings—

   (a)   Fixed lugs

      (i)   There shall be three adjustable fixing lugs to each jamb.

      (ii)   The lugs shall be at least 18 BG (1.2 mm) thick with a minimum outstand of 152 mm.

   (b)   Hinges

      (i)   One pair of 100 mm hinges shall be provided for each door jamb. The hinges shall have 5 knuckles and a removable pin, all made of mild steel. The minimum thickness of the hinge leaves shall be 14 BG (2 mm). The top of the upper hinge shall be positioned 127 mm from the inside of the head of the door and the bottom of the lower hinge shall be 1730 mm from the inside of the head of the door.

      (ii)   When T-hinges are required for batten doors, the T-hinges shall have a minimum thickness of 14 BG (2 mm) and a minimum length of 305 mm.

   (c)   Lock strike plate

      There shall be an adjustable lock strike plate of rust-proofed steel with a mortar guard, to accommodate locks or latches complying with ZS EN 12209. This lock strike plate shall be so placed that the distance from the inside of the rebate at the head to the centre line of the plate shall be 745 mm.

   (d)   Shock absorbers

      (i)   For side hung doors, there shall be at least two rubber buffers inserted in holes in the rebate and located at least 475 mm above and 940 mm below the centre line of the lock strike plate.

      (ii)   For double doors, there shall be at least two rubber buffers inserted in holes in the rebate and located 152 mm on either side of the centre line of the frame at the top.

8.   FINISH

   5.1. Protective coating

      The door frames shall be cleaned of rust, scale and dirt and given a protective shop coat of paint complying with an appropriate standard on dipping primers.

   5.2. Alternative protective coatings

      The provision of other protective coatings shall as agreed between manufacturer and purchaser. If paint primers are specified they shall comply with ZS 201: 1994.

9.   MARKING

   Each door shall be marked with the manufacturer’s name or trade mark.

APPENDIX A

INFORMATION TO BE SUPPLIED BY THE PURCHASER WHEN ORDERING

When ordering metal door frames, the purchaser should clearly indicate the following—

   (a)   The handling of the door. This is determined by the side at which the door is hinged when standing on the pull side as shown in Figure 7.

   (b)   Any special requirements such as single rebated frames or differing profiles (See clause 4.2.).

   (c)   Type of lock or latch (See clause 7(c)).

   (d)   For type 24F door frames, the requirement of the fanlight-hinged or fixed.

Figure 5 - Threshold details

 

Note:

Tie bars welded to underside of jambs for use with 25 mm finished floor.

Figure 6 - Application of doorframes to wall

 

Note:

Where wall thickness exceeds 2 M (nominal 200 mm) doorframes may be sited as desired on wall centre or abutting either inside or outside face.

Figure 7 - Handling of doorframes

 

 

ANNEX A

(Informative)

CHEMICAL NAMES FOR PESTICIDES MENTIONED IN THIS STANDARD

Common name

Chemical name

Aldrin

1,2,3,4,10,10-hexachloro-1,4,4a-5,8,8a-hexahydro-endo-1,4-exo- 5,8-dimethanonaphthalene

Chlordane

1,2,4,5,6,7,8,8-Octachloro-2,3,3a,4,7,7a-hexahydro-4,7-methanoindene

2,4-D

(2,4-dichlorophenoxy) acetic acid

o,p’-DDT

1,1,1-trichloro-2-(o-chlorophenyl) -2-(p-chlorophenyl)-ethane

p,p’-DDT

1,1,1-trichloro-2,2-bis(p-chlorophenyl) ethane

Dieldrin

1,2,3,4,10-10-hexachloro-exo-6,7-epoxy-,4a,5,6,-7,8,8a- octahydro-1,4-endo,exo-5,8-dimethanonaphthalene

Endosulfan (Alpha and beta)

6,7,8,9,10,10-hexachloro-exo-6,7-epoxy-4a,5,6,-7,8,8a-octahydro-1,4-endo, exo-5,8-dimethanonaphthalene

Endrin

1,2,3,4,10,10-hexachloro-6,7-epoxy -1,4,4a,5,6,7,8,8a-octahydro- endo-5,8-dimethanonaphthalene

Heptachlor

1,4,5,6,7,8,8-heptachloro-3a,4,7,7a-tetrahydro-4,7-methanoindene

Hexachlorobenzene

Same name

Lindane (gamma BHC)

1,2,3,4,5,6-a,a,e,e,e-hexachloro-cyclohexane

Methoxychlor

2,2,-bis(p-methoxyphenyl)-1,1,1-trichloroethane

Toxaphene (camphechlor)

Approximately C<BC:0,0,0,DC>10H<BC:0,0,0,DC>10Cl<BC:0,0,0,DC>8

Note:

   1. "p,p’-DDT" is the pure technical form of DDT which is transformed into a family of closely related partial degradation and re-arrangement compounds (o,p’-DDT, DDD, DDE and others) in the environment.

   2. Toxaphene (camphechlor) is a mixture of chlorinated camphenes.

Zambian Standard ZS 389

WHITE SUGAR - SPECIFICATION

1.   SCOPE

   This standard prescribes the requirements for white sugar derived from sugarcane or sugar beet intended for human consumption.

2.   NORMATIVE REFERENCES

   In this standard reference has been made to the following publications—

   Food and Drugs Regulations of Zambia; and

   ZS 033: Parts 1 to 5 - Labelling of prepackaged foods

3.   TYPES OF SUGAR

   White sugar shall be one of the following types classified according to its form—

   (a)   granulated sugar;

   (b)   mill white sugar (plantation white sugar);

   (c)   brown sugar;

   (d)   VHP (very high pol) sugar;

   (e)   Mill white sugar (plantation white sugar);

   (f)   refined sugar;

   (g)   powdered sugar;

   (h)   castor sugar;

   (i)   icing sugar; or

   (j)   sugar cubes.

4.   DEFINITIONS

   In this standard, unless the context otherwise requires—

   "white sugar" means purified crystallised sucrose (saccharose);

   "powdered sugar" means finely pulverised white sugar with or without the addition of an anti-caking agent; and

    "sugar cubes" means granulated sugar in the form of regular hexahedrons or tablets.

5.   COMPOSITIONAL REQUIREMENTS

   The composition of the various types of sugar shall be in accordance with the requirements given in Table 1. In addition to compositional specifications given in Table 1, sugar shall be fortified with vitamin A premix (see Appendix A).

TABLE 1—COMPOSITIONAL REQUIREMENTS OF WHITE SUGAR

Characteristics

Requirements of sugar

 

Granulated

Castor Sugar

Powder (icing sugar)

Sugar Cubes

Brown Sugar

VHP Sugar

Mill White Sugar

Refined Sugar

Polarisation °S, min.

98

99.3

99.5

99.8

99.78

99.78

99.7

Moisture %, max. (at 105° for 3 hours)

0.05

0.05

0.05

0.05

0.04

0.04

0.20

Ash conductivity % m/m, max.

0.10

0.10

0.10

0.04

0.04

0.04

0.04

Invert sugar % (m/m), max.

0.10

0.10

0.10

0.04

0.04

0.04

0.04

Sulphur dioxide mg/kg, max.

70

70

70

20

20

20

20

Colour (ICUMSA UNITS), max.

2000

1500

650

100

100

100

100

Water-insoluble matters, mg/kg, max.

60

60

60

60

Arsenic, ppm, max.

1

1

1

1

1

1

1

Lead, ppm, max.

2

2

2

1

2

2

2

Copper, ppm, max.

2

2

2

2

2

2

2

Vitamin A (as retinol), mg/kg, min.

10

10

10

6.   GENERAL REQUIREMENTS

   Sugar flavour shall be that which is characteristic of white sugar and shall be free from any foreign flavour and odour. The sugar shall be free of traces of pests, rodent and any other contaminants. No colouring matter or ultramarine shall be added to sugar.

6.1. Permissible additives

      Anti-caking agents:

   (a)   The following anti-caking agents may be added to powdered sugar singly or in combination—

      (i)   Magnesium stearate or magnesium carbonate or magnesium trisilicate;

      (ii)   Calcium triphosphate;

      (iii)   Sodium - calcium - alumine - silicate; or

      (iv)   Calcium silicate.

   However, starch shall not be—

      (i)   present; and

      (ii)   more than 1.5 per cent m/m.

   (b)   When no other anti-caking agent is used in powdered sugar, starch can be used up to a maximum of 5 per cent m/m.

   6.2. Sieving requirements

      Not more than 4 per cent shall remain on a 1 mm aperture screen and not more than 8 per cent shall pass through a 0.180 mm (180µ) aperture screen.

   6.3. Hardness of cube sugar

      The pressure required to break each cube shall not be less than 10.5 kg/cm<BC:0,0,0,DC>2.

   6.4. Microbiological requirements

      (a)   Total count of organisms

         When tested in accordance with approved methods the total count of organisms shall not exceed 500 colonies per 1 g.

      (b)   Yeast and moulds

         When tested in accordance with approved methods the total colony counts of yeasts and moulds shall not exceed 50 per 1 g.

      (c)   Escherichia

         When tested in accordance with approved methods the product shall be free from Escherichia coli.

7.   PACKAGING AND MARKING

   7.1. Packing

      Sugar shall be packaged in a plastic film or paper bag made of non-toxic material whichever is applicable or any other suitable package. The material used to package sugar shall be clean and shall protect it from contamination and heat or light.

   7.2. Marking

      The label on the package shall, in addition to complying with the requirements of ZS 033: Parts 1 to 5, bear the following information in legible and indelible marking—

      (a)   name and address of manufacturer, or the manufacturer’s registered trade mark;

      (b)   type of sugar in accordance with clause 3;

      (c)   for powdered sugar name of "anti-caking agent" shall be mentioned;

      (d)   batch number;

      (e)   net weight;

      (f)   number of sugar cubes per pack;

      (g)   retinol content;

      (h)   the words "fortified with vitamin A" in bold letters; and

      (i)   store in a cool dry place away from strong light.

8.   SAMPLING

   8.1. General requirements of sampling for inspection

      (a)   In drawing, preparing, storing and handling samples, the following precautions and directions shall be observed.

      (b)   Samples shall be taken in a protected place not exposed to damp air, dust or soot and sunlight or heat.

      (c)   The sampling instruments shall be clean and dry when used.

      (d)   Sampling for bacteriological purposes

         The sampling instruments and containers for samples shall be sterilised preferably by dry heat at 170°C for one hour before use.

      (e)   Adequate precautions shall be taken to protect the samples, the material being sampled, the sampling instruments and the containers for samples from adventitious contamination.

      (f)   The samples shall be placed in clean and dry moisture proof containers, which may be of glass, plastic or polyethylene materials.

      (g)   Each sample container shall be sealed airtight after filling and marked with the name of the material date of sampling, batch number, and name of the manufacturer and other important particulars of the batch.

      (h)   The sample shall be protected from light as far as practicable and shall be stored in a cool place.

   8.2. Scale of sampling

      (a)   Lot

         All the containers of sugar in a single day’s production shall constitute a lot.

      (b)   Gross sample

         A number of containers not less than the sample size indicated in Table 2 shall be selected at random from a lot for the purpose of drawing samples for test. This number of containers shall constitute the gross sample.

      (c)   To ensure the randomness of selection, a random number table as agreed to between the purchaser and the supplier shall be used. In case such a table is not available the following procedure shall be used—

         Starting from any container count all the containers as 1, 2, 3,.... up to r and so on in one order, where ‘r’ is equal to the integral part of N/n, ‘N’ being the total number of containers in the lot and ‘n’ the number of containers to be selected, (see Table 2). Every ‘rth’ bag thus counted shall be withdrawn for sampling.

      (d)   Containers stacked in pyramidical shape

         In case of bags stacked in a pyramidical shape, approximate equal number of bags shall be selected from all exposed sides of the lot so as to give the required number of sample bags.

TABLE 2—SAMPLING SCALE

Lot Size

Sample Size

(N)

(n)

2-15

2

16-50

3

51-150

5

151-500

8

501-3200

13

3201 and above

20

   8.3. Test samples and reference samples

      (a)   Test samples

         Draw from the top bottom and middle of each container in the gross sample about 1.5 kg of the material with an appropriate sampling instrument. Mix thoroughly the material drawn from all the containers in the gross sample of that particular lot. Divide the composite sample with a suitable raffler into three approximately equal reduced samples.

      (b)   These reduced samples shall constitute the test samples, each test sample being not less than 0.5 kg.

      (c)   The test samples shall be transferred immediately to thoroughly clean dry and sterile glass containers that shall be sealed air tight and labelled with the particulars given in 8.1. (g). The inspecting authority shall take one test sample and the other shall be handed over or sent to the manufacturer or his representative.

      (d)   Reference sample

         The third test sample, bearing the seals of the manufacturer and the inspecting authority shall constitute the reference sample to be used in case of dispute. It shall be kept at a place agreed to between the inspecting authority and the manufacturer, or in the absence of the manufacturer, the manufacturer’s representative.

      (e)   Criterion for compliance

         If on testing the sample is found to conform to the requirements specified in the standard, the batch shall be accepted as complying to this standard.

9.   TEST METHODS

   White sugar shall be tested in accordance with approved methods of test for sugar including Honey.

 

APPENDIX A

REQUIREMENTS FOR VITAMIN A FORTIFICANT PREMIX

   A. 1. The retinol content shall not be less than 15 g/kg.

   A. 2. The vegetable oil

   A. 3. The antioxidant used shall be at levels adequate to prevent peroxidation and rancidity.

   A. 4. The vitamin A fortificant premix shall readily dissolve in water.

   A. 5. The packaging for vitamin A fortificant premix shall be of such quality and design as to protect the fortificant premix from contamination.

   A. 6. The following information shall appear on the label—

      (i)   the date of manufacture;

      (ii)   the retinol content; and

      (i)   the words "VITAMIN A PREMIX NOT FOR DIRECT HUMAN CONSUMPTION" in letters half the size of the trade name.

Zambian Standard ZS 394

AVIATION TURBINE FUEL - SPECIFICATION FOR JET A-1

1.   SCOPE

   This Zambian Standard specifies requirements for Aviation Turbine Fuel, Jet A-1 in particular.

2.   NORMATIVE REFERENCES

   In this standard, reference has been made to the following methods—

   ZS 396 Sampling Petroleum Products Part 1: Manual Sampling of Liquid Hydrocarbons

3.   DEFINITIONS

   In this Standard, unless the context otherwise requires—

   "Additive" means a compound added to aviation turbine fuel to improve performance or storage stability.

4.   REQUIREMENTS

   4.1. General

      (i)   The aviation turbine fuel shall be hydrocarbon oil derived from petroleum or fossil fuels. This does not preclude the incorporation of small amounts of additives intended to improve some aspects of performance. The product shall be free from inorganic acid and from quantities of grit, fibrous material and other foreign matter likely to interfere with the operation of normal equipment.

      (ii)   When tested in accordance with the methods of test given in Table 1, aviation turbine fuel shall be in accordance with the limiting requirements given in the Table.

      (iii)   On visual inspection at ambient temperature, the aviation turbine fuel shall be clear, bright and free from solid matter.

   4.2. Storage stability

      After conventional storage under normal conditions for a period of six months after the date of receipt, the aviation turbine fuel shall still comply with all the requirements of this standard (other than the requirements for potential gum content).

5.   PACKAGING AND MARKING

   5.1. Packaging

      The condition of the containers, rail tankers and road tank vehicles into which the aviation turbine fuel is filled shall be such as not to be detrimental to the quality of the fuel during normal transportation and storage. The containers shall be acceptably sealed and in addition shall conform to the Petroleum Act, Chapter 435 of the Laws of Zambia, and ZS 371.

   5.2. Marking

      The following information shall appear in legible and indelible marking on each container or in the case of aviation turbine fuel filled into bulk storage tanks, with the storage and consignment documents of each road tanker or rail wagon as stipulated in ZS 372—

      (i)   the manufacturer’s name and address;

      (ii)   the type of fuel as stipulated under UN Code;

      (iii)   the hazards involved in handling and transportation;

      (iv)   the Transport Emergency Card (Tremcard);

      (v)   the volume in litres; and

      (vi)   the batch/lot number.

6.   TEST METHODS

   For all characteristics, the test methods listed in column 4 of Table 1 shall apply.

7.   SAMPLING

   7.1. Sampling from storage tanks

      For the purpose of this Standard all sampling shall be carried out in accordance with the relevant procedures of ZS 396: Part 1 and, additionally, as detailed in 7.2.

   7.2. Sampling from fuel lines

      (a)   Sampling cans of 5 litres and 1 litre capacity

         The construction of the cans shall comply with the appropriate safety requirements for cans that are to hold highly flammable material. They shall be provided with screw caps incorporating a petroleum resistant washer in good condition. A stock of cans shall be kept solely for the purpose of taking Aviation Turbine Fuel samples.

      (b)   Preparation of cans

         New cans shall be rinsed with Aviation Turbine Fuel before being used to remove any residual traces of oil left during manufacturing operations, and then allowed to dry. Before use, all cans shall be checked to ensure that they are sound and free from leaks.

      (c)   Sampling procedure

         From the pump nozzle, 5 litres of Aviation Turbine Fuel shall be drawn carefully into a cool 5 litres can using a clean dry funnel. Immediately afterwards, this sample shall be decanted carefully into the requisite number of one litre cans using a funnel, filling the cans within 15 mm of the brim.

         If more than 5 litres are needed, the operation shall be repeated immediately and before the pump has been used for any other purpose. The screw caps shall be tightened fully and the cans checked to ensure that there are no leaks.

         The sampling procedure shall not be carried out in direct sunlight. If carried out in direct sunlight, changes in fuel quality may occur.

      (d)   Storage, labelling and transport

<PS:"QT-TTTI">         (i)   Samples shall be kept in a cool place although it is not necessary to keep them refrigerated.
<PS:"QT-TTTI">         (ii)   Full and legible information relating to the source of the sample shall be attached to the can in such a manner that it will not easily become detached subsequently.
<PS:"QT-TTTI">         (iii)   If required, the sample may be sealed and labeled to maintain its integrity.
<PS:"QT-TTTI">         (iv)   If the sample has to be sent to a laboratory by public transport, it will be necessary to comply with the general regulations covering transportation of flammable materials and with the requirements of the transport authority concerned. Information on the appropriate procedures and the type of packaging required should be obtained from the transport authority involved.

TABLE1—REQUIREMENTS FOR AVIATION TURBINE FUEL (JET A-1)

Characteristics

Limit

Requirement

Test method

COMPOSITION

     

Acidity (mgKOH/g)

Max

0.015

ASTM D 3242, IP 354

Aromatics (% vol)

Max

22

ASTM D 1319, IP 156

Doctor Test<BC:0,0,0,DC>1)

 

Negative

ASTM D 4952

Sulphur, Mercaptan (% m/m)

Max

0.003

ASTM D 3227

Sulphur, Total (% m/m )

Max

0.30

ASTM D 1266, D 1552,

   

D 2622, D 4294 or 5453

Colour

 

Report

ASTM D 156

VOLATILITY

     

Distillation Temperatures

   

ASTM D 86

10% Recovered, Temperature, °C

Max

205

ASTM D 86

End Boiling Point, Temperature, °C

Max

300

ASTM D 86

Distillation Residue, (% vol)

Max

1.5

ASTM D 86

Distillation Loss, (% vol)

Max

1.5

ASTM D 86

Flash Point, (°C)

Min

38

ASTM D 56, D 3828 or
IP 170

Density at 15°C, (kg/m<BC:0,0,0,DC>3)

 

775 to 840

ASTM D 1298, D 4052

FLUIDITY

     

Freezing Point, (°C)

Max

-47

ASTM D 2385, D 2386,
D 5901, D 5972

Viscosity @ -20°C, (mm<BC:0,0,0,DC>2/s)

Max

8

ASTM D 445

COMBUSTION

     

Net Heat of Combustion, (MJ/kg)

Min

42.8

ASTM D 4529, D 3338
or D 4809

One of the following requirements shall be met—

     

Luminometer Number

Min

45

ASTM D 1740

Smoke Point, (mm)

Min

25

ASTM D 1322

Smoke Point, (mm) and

Min

19

ASTM D 1322

Naphthalenes (% vol)

Max

3

ASTM D 1322

CORROSION

     

Copper Strip, 2 hours at 100°C

Max

1

ASTM D 130

Ag Corrosion, 4 hours at 50°C

Max

2

IP 227

STABILITY

     

Thermal:

Max

25

ASTM D 3241

Filter Pressure Drop, (mm Hg)

Max

3

ASTM D 3241

Tube Deposit less than

     

CONTAMINANTS

     

Existent Gum, (mg/100 ml)

Max

7

ASTM D 381

Water Reaction:

     

Interface Rating

Max

1b

ASTM D 1094

Water Separator Index

Min

70

ASTM D 2550

CONDUCTIVITY

     

Electrical Conductivity, (pS/m)

 

50-450

ASTM D 2624

ADDITIVES

     

Anti-oxidant, (mg/l)

     

Hydrotreated Fuels (Mandatory)

Min

17

ASTM D 2550

 

Max

24

ASTM D 2550

Non Hydrotreated Fuels (Optional)

Max

24

ASTM D 2550

Metal Deactivator, (mg/l)

Max

5.7

ASTM D 2550

Static Dissipator (Mandatory)

     

First Doping, (mg/l)

Max

3.0

ASTM D 2550

Cumulative Doping, (mg/l)

Max

5.0

ASTM D 2550

<BC:0,0,0,DC>(1)   A positive Doctor Test result will not stop a sample from qualifying providing that the Mercaptan Sulphur Result is within specification.

Zambian Standard ZS 422-1

PENETRATION GRADE BITUMENS - SPECIFICATION

1.   SCOPE

   This Part of the ZS 422 specifies the requirements for penetration grade bitumens which are suitable for use in road construction in Zambia. The penetration grade bitumens are classified into a number of grades for each of which an appropriate designation and properties are specified.

   This Part of the standard does not cover bitumen emulsions, cut back bitumens or bitumen mixtures containing lake asphalt, coal tar or pitch; such materials are specified in a separate standard. Advice on handling and packaging, and on sampling and testing is given in the Appendices A and B.

2.   REFERENCES

   In this standard, reference has been made to the following methods—

   ZS 396 Sampling Petroleum Products - Part 1: Manual sampling of liquid hydrocarbons

3.   DEFINITIONS

   For the purpose of this standard, the following definition applies—

   3.1. Bitumen

      A viscous liquid, or solid, consisting essentially of hydrocarbons and their derivatives, which is soluble in trichloroethylene and is substantially non-volatile and softens gradually when heated. It is black or brown in colour and possesses waterproofing and adhesive properties. It is obtained by a refinery process from petroleum, and is found as a natural deposit or as a component of naturally occurring asphalt, in which it is associated with mineral matter.

4.   REQUIREMENTS

   4.1. General

      When tested in accordance with the methods of test given in Table 1, the penetration grade bitumen shall be within the limiting requirements given in the Table.

      Numbers representing the penetration range designate penetration grade of bitumen specified in this Part of the standard. Penetration grades are also referred to using the suffix ‘pen’.

   4.2. Storage stability

      (a)   General

         Penetration grade bitumens require storage and handling plant equipped with heating facilities. However, this does depend on the cutback grade of the bitumen being handled.

         After conventional storage under normal conditions for a period of up to 6 months after the date of manufacture, the penetration grade bitumen shall comply with all the requirements of this standard.

         In the case of penetration grade bitumen that is stored for more than 6 months, the product shall comply with the requirements of Table 1. It shall comply with such other requirements as are agreed upon between the supplier and purchaser.

      (b)   Marking

         The following information shall appear in legible and indelible marking on each container or in the case of products being transported in a road tank vehicle, in the storage and consignment documents—

<PS:"QT-TTTI">         (i)   the supplier’s name and address;
<PS:"QT-TTTI">         (ii)   the date of manufacture;
<PS:"QT-TTTI">         (iii)   the name of the product, e.g. 150/200 pen bitumen;
<PS:"QT-TTTI">         (iv)   the quantity in kg;
<PS:"QT-TTTI">         (v)   the batch/lot number;
<PS:"QT-TTTI">         (vi)   a statement on safety, health and environment.

5.   TEST METHODS

   For all characteristics, use the applicable methods listed in column 7 of Table 1.

TABLE 1—REQUIREMENTS FOR PENETRATION GRADED BITUMENS

1

2

3

4

5

6

7

   

GRADE

 

CHARACTERISTIC

LIMIT

40/50 pen

60/70 pen

80/100 pen

150/200 pen

TEST METHOD

Penetration @ 25°C, 0.1 mm (100g/5s)

Range

40-50

60-70

80-100

150-200

ASTM D 5

Softening Point, °C

Min

49

46

41

36

IP 58

Max

59

56

51

43

ASTM D 36

Ductility @ 25°C, mm

Min

1000

1000

1000

1000

ASTM D 113

Rolling Thin Film Oven Test Loss on Heating, % m/m

Max

0.8

1.0

1.0

1.4

ASTM D 2872

Retained Penetration of Residue, % of Original

 

60 min

55 min

50 min

45 min

ASTM D 5 IP 49

Ductility of Residue @ 25°C, mm

Min

400

600

1000

1000

ASTM D 113

Solubility, Trichloroethylene, % m/m

Min

99.0

99.0

99.0

99.0

ASTM D 2042 IP 47

Viscosity @ 135°C, Pa.s

Min

0.27

0.22

0.15

0.12

ASTM D 4402 IP 319

APPENDIX A

(Normative)

HANDLING AND PACKAGING

A. 1. Handling and Packaging

   Penetration grade bitumens are normally supplied hot in bulk by road tanker, and handling procedures should be in accordance with the latest revision of the Institute of Petroleum Model Code of Safe Practice, Part 11, Bitumen Safety Code or the Bitumen Safety Handbook published by SABITA. Penetration grade bitumen may also be supplied in sealed drums and suppliers’ recommendations should be sought with regard to appropriate handling procedures. The condition of the containers and road tank vehicles into which the penetration grade bitumen is filled shall be such as not to be detrimental to the quality of the product during normal transportation and storage. The drums shall be sealed and shall conform to the Petroleum Act, Chapter 435 of the Laws of Zambia.

APPENDIX B

(Normative)

SAMPLING AND TESTING

B. 1.    Sampling Locations

B. 1.1. For the purposes of this Zambian Standard all sampling shall be carried out in accordance with the relevant procedures of ZS 396. In addition, if it is desired to take a sample of penetration grade bitumen it may be taken from any of the following locations—

   (a)   from the tanker, in the case of bulk delivery by road, immediately before discharge;

   (b)   from the storage tank (or the feed pipe to the mixer) of a manufacturer of mixtures of bitumen and mineral matter, immediately before mixing; or

   (c)   from the tank of a binder distributor used for surface dressing immediately before spraying.

B. 2. Sampling Procedures

   When sampling penetration grade bitumen it is essential that the purchaser obtain a sample of not less than 5 kg, which represents the material supplied. The sample shall be immediately divided into three approximately equal sub-samples that shall be placed in clean and dry metal containers capable of being securely closed. Each sub-sample shall be clearly labelled with the names of the supplier and purchaser, details of the grades of penetration grade bitumen, time and date of sampling and identification of the sampling location. Samples should be retained for at least three months.

   It is essential that the purchaser use only one of the sub-samples for the purchaser's own tests, the remaining two sub-samples being retained by the purchaser in case of dispute.

Note:

   1. It is recommended that routine checking of penetration grade bitumen should be based on the penetration test and softening point in the case of grades covered in Table 1. Experience shows that checking other specified properties is only necessary when there are reasons to suspect the quality of the material.

   2. To ensure valid comparison between the test results of the purchaser and supplier, it is essential that both test the material within 7 days of taking the sample.

 

Zambian Standard ZS 422-2

CUTBACK BITUMENS - SPECIFICATION

1.   SCOPE

   This Part of ZS 422 specifies the requirements for cutback bitumens which are suitable for use in road construction in Zambia. The cutback bitumens are classified into a number of grades for each of which an appropriate designation and properties are specified.

   This Part of the standard does not cover penetration grade bitumens, bitumen emulsions or bitumen mixtures containing lake asphalt, coal tar or pitch. Advice on handling and packaging, and on sampling and testing is given in the Appendices A and B.

2.   NORMATIVE REFERENCES

   In this standard, reference has been made to the following methods—

   ZS 396 Sampling Petroleum Products - Part 1: Manual sampling of liquid hydrocarbons

3.   DEFINITIONS

   For the purpose of this standard, the following definitions as well as those defined in Part 1 apply—

   "bitumen" means a viscous liquid, or solid, consisting essentially of hydrocarbons and their derivatives, which is soluble in trichloroethylene and is substantially non-volatile and softens gradually when heated and—

   (i)   it is black or brown in colour and possesses waterproofing and adhesive properties; and

   (ii)   it is obtained by a refinery process from petroleum, and is found as a natural deposit or as a component of naturally occurring asphalt, in which it is associated with mineral matter; and

   "cutback bitumen" means bitumen whose viscosity has been reduced by blending with a suitable volatile diluent. It is viscous at ambient temperatures and some grades will require heating before mixing and spraying. Cutback bitumen shall be homogenous, free from visible water and will not foam when heated to application temperature.

4.   REQUIREMENTS

   4.1. General

      When tested in accordance with the methods of test given in Table 1, the cutback bitumen shall be within the limiting requirements given in the Table.

   4.2. Storage stability

      (a)   General

         Cutback bitumens require storage and handling plant equipped with heating facilities. However, this does depend on the cutback grade of the bitumen being handled.

         After conventional storage under normal conditions for a period of up to 6 months after the date of manufacture, the cutback bitumen shall comply with all the requirements of this standard.

         In the case of cutback bitumen that is stored for more than 6 months, the product shall comply with the requirements of Table 1. It shall comply with such other requirements as are agreed upon between the supplier and purchaser.

      (b)   Marking

         The following information shall appear in legible and indelible marking on each container or in the case of cutback bitumen being transported in a road tank vehicle, in the storage and consignment documents—

<PS:"QT-TTTI">         (i)   the supplier’s name and address;
<PS:"QT-TTTI">         (ii)   the date of manufacture;
<PS:"QT-TTTI">         (iii)   the name of the product, e.g. MC 30 cutback bitumen;
<PS:"QT-TTTI">         (iv)   the quantity in kg;
<PS:"QT-TTTI">         (v)   the batch/lot number; and
<PS:"QT-TTTI">         (vi)   a statement on safety, health and environment.

5.   TEST METHODS

   For all characteristics, use the applicable methods listed in column 10 of Table 1.

TABLE 1—REQUIREMENTS FOR CUTBACK BITUMENS<BC:0,0,0,DC>1

1

2

3

4

5

6

7

8

9

10

 

GRADE

 

CHARACTERISTIC<BC:0,0,0,DC>4

MC 30

MC 70

MC 800

MC 3000

TEST METHOD

 

Min

Max

Min

Max

Min

Max

Min

Max

 

Kinematic viscosity @ 60°C, cSt

30

60

70

140

800

1600

3000

6000

ASTM D2170

Flash point, °C

38

 

38

 

66

 

66

 

IP 113 or ASTM D 1310<BC:0,0,0,DC>1

Distillation, % by vol of total distillate to 360°C—

                 

to 190 °C

0

15

IP 27

to 225 °C

15

60

10

50

0

35

0

25

ASTM D

to 260 °C

50

85

40

80

10

60

0

40

402

to 316 °C

80

100

80

95

50

90

35

85

 

Residue from distillation to 360°C, % vol of original sample

50

55

75

80

IP 27 ASTM D 402

Penetration at 25°C on residue from distillation, 0.1 mm

90

180

90

180

90

180

90

180

IP 49A STM D 5

Ductility on residue from distillation @ 25°C, mm

1000

 

1000

 

1000

 

1000

 

ASTM D 113

Solubility Trichloroethylene, % m/m

99.0

 

99.0

 

99.0

 

99.0

 

ASTM D 2042

Water, % volume

 

0.2

 

0.2

 

0.2

 

0.2

ASTM D 95

<BC:0,0,0,DC>1   All cutbacks shall be blended from pen 80 – 100 grade bitumen.

<BC:0,0,0,DC>2   Cutback bitumen shall be homogenous, free from visible water and will not foam when heated to application temperature.

<BC:0,0,0,DC>3   IP 113 and ASTM D 1310 are acceptable methods to be used to determine the flash point although cognisance should be taken of the diluent used to make the cutback bitumen as this will affect the accuracy of results obtained.

 

APPENDIX A

(Normative)

HANDLING AND PACKAGING

A. 1. Handling and Packaging

   Cutback bitumens are normally supplied hot in bulk by road tanker. Handling procedures should be in accordance with the latest revision of the Institute of Petroleum Model Code of Safe Practice, Part 11, Bitumen Safety Code or the Bitumen Safety Handbook published by SABITA. Uncontrolled heating of cutback bitumens can lead to loss of volatile diluent and consequent non-compliance with the specification.

   Cutback bitumen may also be supplied in sealed drums and suppliers’ recommendations should be sought with regard to appropriate handling procedures. The condition of the containers and road tank vehicles into which the cutback bitumen is filled shall be such as not to be detrimental to the quality and quantity of the product during normal transportation and storage. The drums shall be sealed and shall conform to the Petroleum Act, Chapter 435 of the Laws of Zambia.

APPENDIX B

(Normative)

SAMPLING AND TESTING

B.1. Sampling Locations

   B.1.1. For the purposes of this Zambian Standard all sampling shall be carried out in accordance with the relevant procedures of ZS 396. In addition, if it is desired to take a sample of cutback bitumen it may be taken from any of the following locations—

<PS:"QT-TTI">      (a)   from the tanker, in the case of bulk delivery by road, immediately before discharge;
<PS:"QT-TTI">      (b)   from the storage tank (or the feed pipe to the mixer) of a manufacturer of mixtures of bitumen and mineral matter, immediately before mixing; or
<PS:"QT-TTI">      (c)   from the tank of a binder distributor used for surface dressing immediately before spraying.

   B.1.2. The procedures involved in handling the binder for surface dressing may lead to some loss of volatile constituents from the cutback bitumen without necessarily impairing the performance of the surface dressing. Where a sample of cutback bitumen has been taken from one of the locations listed in B.1.1 it shall be assumed that the viscosity requirements of the standard have been complied with provided the viscosity is within the following limits—

   Saybolt - Furol Viscosity Limits

   MC-30 - Furol Viscosity at 25°C - 75 to 150 sec

   MC-70 - Furol Viscosity at 50°C - 60 to 120 sec

   MC-800 - Furol Viscosity at 82.2°C - 100 to 200 sec

   MC-3000 - Furol Viscosity at 82.2°C - 300 to 600 sec

B.2. Sampling Procedures

   When sampling cutback bitumen it is essential that the purchaser obtain a sample of not less than 5 kg, which represents the material supplied. The sample shall be immediately divided into three approximately equal sub-samples that shall be placed in clean and dry metal containers capable of being securely closed. Each sub-sample shall be clearly labelled with the names of the supplier and purchaser, details of the grades of cutback bitumen, time and date of sampling and identification of the sampling location. Samples should be retained for at least three months.

   It is essential that the purchaser use only one of the sub-samples for the purchaser’s own tests, with the remaining two sub-samples being retained by the purchaser in case of dispute.

Note:

   1. It is recommended that routine checking of cutback bitumen should be based on the viscosity test in the case of grades covered in Table 1. Experience shows that checking other specified properties is only necessary when there are reasons to suspect the quality of the material.

   2. To ensure valid comparison between the test results of the purchaser and supplier, it is essential that both test samples are of the same age.

 

SECOND SCHEDULE

[Paragraph 3]

1.

ZS 063

Petroleum Jelly

2.

ZS 065

Pure Glycerine

3.

ZS 190

Drinking Water

4.

ZS 233

Crude Edible Vegetable Oils

5.

ZS 327

Blended (Physical Mixture) Fertilisers

6.

ZS 357

Pressed Steel Door Frames

7.

ZS 373 Part 1

Portable Fire Extinguishers

8.

ZS 373 Part 2

Portable Fire Extinguishers

9.

ZS 389

White Sugar

10.

ZS 394

Aviation Turbine Fuel

11.

ZS 422 Part 1

Penetration Grade Bitumens

12.

ZS 422 Part 2

Cutback Bitumens

 

STANDARDS ACT (COMMENCEMENT) ORDER, 2017

[Section 1]

Arrangement of Paragraphs

   Paragraph

   1. Title

   2. Commencement of Act No. 4 of 2017

SI 87 of 2017.

 

1. Title

This Order may be cited as the Standards Act (Commencement) Order, 2017.

 

2. Commencement of Act No. 4 of 2017

The Standards Act, 2017, shall come into operation on 1st January, 2018.

{/mprestriction}